Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures

被引:2
|
作者
Lemoine, Marc D. [1 ,2 ]
Obergassel, Julius [1 ,2 ]
Jaeckle, Sandro [1 ]
Nies, Moritz [1 ,2 ]
Taraba, Sophia [1 ]
Mencke, Celine [1 ]
Riess, Jan [1 ,2 ]
My, Ilaria [1 ,2 ]
Rottner, Laura [1 ,2 ]
Moser, Fabian [1 ,2 ]
Ismaili, Djemail [1 ,2 ]
Reissmann, Bruno [1 ,2 ]
Ouyang, Feifan [1 ,2 ]
Kirchhof, Paulus [1 ,2 ,3 ]
Rillig, Andreas [1 ,2 ]
Metzner, Andreas [1 ,2 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site, Hamburg, Germany
[3] Univ Birmingham, Inst Cardiovasc Sci, Birmingham, England
来源
EUROPACE | 2024年 / 26卷 / 09期
基金
英国医学研究理事会;
关键词
Pulsed-field ablation; Cryoballoon; Atrial fibrillation; Pulmonary vein isolation; Reconduction; Repeat ablation; Reisolation; Atrial tachycardia; PAROXYSMAL ATRIAL-FIBRILLATION; 2ND-GENERATION CRYOBALLOON; RADIOFREQUENCY ABLATION; CONTACT-FORCE; OUTCOMES; DURABILITY;
D O I
10.1093/europace/euae221
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI.Methods and result A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation.Conclusion During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar. Graphical Abstract
引用
收藏
页数:11
相关论文
共 50 条
  • [41] High rate of durable pulmonary vein isolation after second-generation cryoballoon ablation: analysis of repeat procedures
    Bordignon, Stefano
    Fuernkranz, Alexander
    Perrotta, Laura
    Dugo, Daniela
    Konstantinou, Athanasios
    Nowak, Bernd
    Schulte-Hahn, Britta
    Schmidt, Boris
    Chun, Kyoung Ryul Julian
    EUROPACE, 2015, 17 (05): : 725 - 731
  • [42] Making the invisible visible - Ultra-high-resolution mapping to identify residual pulmonary vein conduction immediately after cryoballoon-based pulmonary vein isolation
    Saguner, Ardan M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 270 : 180 - 182
  • [43] Pulmonary vein reconnection and repeat ablation characteristics following cryoballoon- compared to radio frequency-based pulmonary vein isolation
    Obergassel, J.
    Nies, M.
    Kirchhof, P.
    Metzner, A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (10) : 2085 - 2085
  • [44] A novel saline-based occlusion tool allows for dye-less cryoballoon-based pulmonary vein isolation and fluoroscopy reduction
    Rottner, Laura
    Obergassel, Julius
    Borof, Katrin
    My, Ilaria
    Moser, Fabian
    Lemoine, Marc
    Wenzel, Jan-Per
    Kirchhof, Paulus
    Ouyang, Feifan
    Reissmann, Bruno
    Metzner, Andreas
    Rillig, Andreas
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [45] Periatrial epicardial adipose tissue thickness is an independent predictor of atrial fibrillation recurrence after cryoballoon-based pulmonary vein isolation
    Kocyigit, Duygu
    Gurses, Kadri Murat
    Yalcin, Muhammed Ulvi
    Turk, Gamze
    Evranos, Banu
    Yorgun, Hikmet
    Sahiner, Mehmet Levent
    Kaya, Ergun Baris
    Hazirolan, Tuncay
    Tokgozoglu, Lale
    Oto, Mehmet Ali
    Ozer, Necla
    Aytemir, Kudret
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (04) : 295 - 302
  • [46] Does Size Matter? Cryoballoon-Based Pulmonary Vein Isolation Using a Novel 25-mm Circular Mapping Catheter
    Reissmann, Bruno
    Schlueter, Michael
    Santoro, Francesco
    Maurer, Tilman
    Heeger, Christian-Hendrik
    Lemes, Christine
    Fink, Thomas
    Riedl, Johannes
    Rillig, Andreas
    Mathew, Shibu
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Metzner, Andreas
    CIRCULATION JOURNAL, 2018, 82 (03) : 666 - 671
  • [47] Wide antral circumferential vs. ostial pulmonary vein isolation using pulsed field ablation-the butterfly effect
    Tilz, Roland R.
    Heeger, Christian H.
    Vogler, Julia
    Eitel, Charlotte
    Feher, Marcel
    Phan, Huong-Lan
    Mushfiq, Ilias
    Popescu, Sorin S.
    Zetzsch, Leonie
    Traub, Anna
    Hatahet, Sascha
    Mortensen, Kai
    Kuck, Karl-Heinz
    Kirstein, Bettina
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [48] Pulmonary Vein Isolation by Pulsed-field Ablation Induces Less Neurocardiac Damage Than Cryoballoon Ablation
    Lemoine, Marc D.
    Mencke, Celine
    Nies, Moritz
    Obergassel, Julius
    Scherschel, Katharina
    Wieboldt, Hartwig
    Schleberger, Ruben
    My, Ilaria
    Rottner, Laura
    Moser, Julia
    Kany, Shinwan
    Wenzel, Jan-Per
    Moser, Fabian
    Dinshaw, Leon
    Muenkler, Paula
    Reissmann, Bruno
    Ouyang, Feifan
    Meyer, Christian
    Blankenberg, Stefan
    Zeller, Tanja
    Fabritz, Larissa
    Rillig, Andreas
    Metzner, Andreas
    Kirchhof, Paulus
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2023, 16 (04): : E011598
  • [49] Troponin release after pulmonary vein isolation using pulsed field ablation compared to radiofrequency and cryoballoon ablation
    Krisai, Philipp
    Knecht, Sven
    Badertscher, Patrick
    Muhl, Aline
    Osswald, Stefan
    Roten, Laurent
    Reichlin, Tobias
    Sticherling, Christian
    Kuhne, Michael
    HEART RHYTHM, 2022, 19 (09) : 1471 - 1472
  • [50] Validation of a multipolar pulsed field ablation catheter for endpoint assessment in pulmonary vein isolation procedures
    Kueffer, T.
    Baldinger, S. H.
    Servatius, H.
    Madaffari, A.
    Seiler, J.
    Muhl, A.
    Franzeck, F.
    Thalmann, G.
    Asatryan, B.
    Haeberlin, A.
    Noti, F.
    Tanner, H.
    Roten, L.
    Reichlin, T.
    SWISS MEDICAL WEEKLY, 2022, 152 : 29S - 29S