Rapid Fault Diagnosis and Location Technique of Overhead Line based on Quantum Algorithm Optimization

被引:0
|
作者
Jiang, Hao [1 ]
Zhang, Boxian [2 ]
Sun, Ranran [3 ]
Qian, Yining [4 ]
机构
[1] Ningbo Power Supply Co, State Grid Zhejiang Elect Power Co Ltd, Elect Engn, Ningbo 315000, Peoples R China
[2] Ningbo Power Supply Co, State Grid Zhejiang Elect Power Co Ltd, Distribut Automat & Network Secur, Ningbo 315000, Peoples R China
[3] Ningbo Power Supply Co, State Grid Zhejiang Elect Power Co Ltd, Distribut Network Technol, Distribut Automat Technol, Ningbo 315000, Peoples R China
[4] Ningbo Power Supply Co, State Grid Zhejiang Elect Power Co Ltd, Distribut Network Technol, Distribut Automat Technol, Ningbo 315000, Peoples R China
关键词
voltage; frequency component; fault location (FL); Overhead transmission line (OHTL); fault diagnosis; Quantum-centric galactic search optimized support vector regression (QGSO-SVR);
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
An innovative approach for diagnosing the kind and phase of faults on overhead transmission lines (OHTLs) is presented in this research. Quantum-centric galactic search optimized support vector regression (QGSO-SVR) is proposed in this work for an effective fault detection process. Data instances, or signals, are obtained at the transmitting and receiving portions of the line to evaluate the effectiveness of the suggested method. Principal component analysis (PCA) is used to identify the important features from the raw data after wavelet transform (WT) has been used to reduce the signal's volume of data without compromising the detection accuracy. The suggested model is trained using frequencies across various fault regions. Further improvements are made to the SVR's fault detection technique according to quantum characteristics in the galactic optimization procedure. Estimating the location of the defect comes after identifying the faulty phase or phases. The suggested approach is used to analyze effectiveness regarding speed and precision using the Matlab tool. Extensive simulation was conducted for different levels of fault resistances (FR), inception angles, and positions. It was researched how noise affects the current and voltage measurements. Based on the analysis of the experiments, the proposed approach has provided 267.85 km in speed which seems to be the best technique for identifying fault diagnosis and location of overhead line.
引用
收藏
页码:600 / 610
页数:11
相关论文
共 50 条
  • [31] A survey of fault location on transmission line based on synchronized phasor measurement technique
    Wang, Bo
    Wang, Wei
    Chen, Chao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (13): : 122 - 128
  • [32] Grounding fault location method of overhead line based on dual-axis magnetic field trajectory
    Wang, Xiaowei
    Du, Huan
    Gao, Jie
    Wei, Xiangxiang
    Liang, Zhenfeng
    Guo, Liang
    Liu, Weibo
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2023, 8 (01)
  • [33] Travelling Wave-Based Fault Location Scheme for Aged Underground Cable Combined with Overhead Line
    Gilany, Mahmoud I.
    Eldin, El Sayed M. Tag
    Aziz, Mohamed Mamdouh Abdel
    Ibrahim, Doaa K.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2005, 2 (02):
  • [34] A novel quantum ant colony optimization algorithm and its application to fault diagnosis
    Wang, Ling
    Niu, Qun
    Fei, Minrei
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2008, 30 (3-4) : 313 - 329
  • [35] Intelligence Scheme for Fault Location in a Combined Overhead Transmission Line & Underground Cable
    Ray, Papia
    Arya, Sabha Raj
    Mishra, Debani Prasad
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2018, 19 (05):
  • [36] LINE FAULT LOCATION FEATURES IN THE HVDC LINES CONTAINING CABLE AND OVERHEAD SEGMENTS
    Ivanova, Elena A.
    Lozinova, Nataliya G.
    BULLETIN OF THE TOMSK POLYTECHNIC UNIVERSITY-GEO ASSETS ENGINEERING, 2016, 327 (08): : 17 - 27
  • [37] Synchronised/unsynchronised measurements based novel fault location algorithm for transmission line
    Hinge, Trupti
    Dambhare, Sanjay
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (07) : 1493 - 1500
  • [38] An accurate scheme for fault location in combined overhead line with underground power cable
    Gilany, M
    El Din, EST
    Aziz, MMA
    Ibrahim, DK
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 2521 - 2527
  • [39] Parameter Identification Algorithm for Fault Location Based on Distributed Transmission Line model
    Kang, Xiaoning
    Jiale, Suonan
    Bo, Zhiqian
    Tang, Jian
    Jun, Qi
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4098 - +
  • [40] Transmission Line Fault Location Based on Improved Algorithm of Electromagnetic Time Reversal
    Liu, Qing
    Yang, Jiayi
    Fu, Yao
    Huang, Yuhe
    IEEE ACCESS, 2022, 10 : 37839 - 37847