Phase-shifting multimode FLRD technique with MSM structure for RI measurement

被引:1
|
作者
Xiang, Peng [1 ]
Yu, Aodi [1 ]
Zheng, Dongqiao [1 ]
Li, Can [1 ]
Li, Wei [1 ]
Xia, Li [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Opt & Elect Informat, Wuhan 430074, Peoples R China
来源
关键词
Fiber-optic refractive index sensor; Multimode fiber-optic loop ring down; Intense light; High-sensitivity; Excellent temperature stability; FIBER CAVITY RING; REFRACTIVE-INDEX; LOOP RING; MAGNETIC FLUID; SENSOR; FIELD; SYSTEM; FBG;
D O I
10.1016/j.optlastec.2024.111585
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A high-sensitivity fiber-optic refractive index (RI) sensor based on phase-shifting multimode fiber-optic loop ring down (PS-MFLRD) technology and multimode-single-mode-multimode (MSM) structure is proposed. The multimode coupler and combiner form a loop with intense light, eliminating the need for an additional Erbium Doped Fiber Amplifier (EDFA) in this system. In addition, The MSM structure's loss varies linearly with the RI of the surrounding environment, enabling RI measurement through phase monitoring. Experimental results demonstrate a sensitivity of 10 deg/RIU within the range of 1.353 to 1.388, and the corresponding linearity R-2 of 0.9927 is obtained, it also has excellent temperature stability at temperatures from 20 degrees C to 80 degrees with a fluctuation range of only 0.006 deg. More importantly, under the same configuration, the single mode structure has a sensitivity of only 0.6 deg/RIU, a difference of 17 times. In addition, the resolution limit of this system is 1.0 x 10(-6) RIU. The proposal of MFLRD provides an effective solution for improving the sensitivity of subsequent RI measurements and simplifying devices.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] ALGORITHM FOR PHASE-DIFFERENCE MEASUREMENT IN PHASE-SHIFTING INTERFEROMETRY
    VIKRAM, CS
    WITHEROW, WK
    TROLINGER, JD
    APPLIED OPTICS, 1993, 32 (31): : 6250 - 6252
  • [32] Phase Measurement of RF Devices Using Phase-Shifting Interferometry
    Will, Karl
    Omar, Abbas
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (11) : 2642 - 2647
  • [33] Effect of quantization error on the computed phase of phase-shifting measurement
    Tongji Univ, Shanghai, China
    Guangxue Xuebao/Acta Optica Sinica, 1996, 16 (12): : 1767 - 1772
  • [34] Phase-shifting method for circular grating Moire technique
    Zhang, HY
    Wang, C
    Liu, XM
    Liu, CG
    ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY 2000, 2000, 4231 : 603 - 607
  • [35] Phase-shifting Zernike phase contrast microscopy for quantitative phase measurement
    Gao, Peng
    Yao, Baoli
    Harder, Irina
    Lindlein, Norbert
    Torcal-Milla, Francisco Jose
    OPTICS LETTERS, 2011, 36 (21) : 4305 - 4307
  • [36] Reasons for Ambiguity in Retardation Calculations in Phase-shifting Technique
    Vinayak, G.
    Mangal, S. K.
    Ramesh, K.
    STRAIN, 2001, 37 (02) : 53 - 54
  • [37] ALTERNATIVE 90-DEGREES PHASE-SHIFTING TECHNIQUE
    KONN, R
    GENIN, R
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1979, 47 (05) : 515 - 518
  • [38] A new route for length measurement by phase-shifting interferometry
    LUO ZhiYong * & LI ZhangHong National Institute of Metrology
    Science China(Physics,Mechanics & Astronomy), 2012, Mechanics & Astronomy)2012 (04) : 599 - 604
  • [39] Phase-shifting interference microscope with extendable field of measurement
    Lin, Shyh-Tsong
    Hsu, Wei-Feng
    Wang, Ming-Shiang
    JOURNAL OF OPTICS, 2018, 20 (04)
  • [40] Phase-shifting polarization interferometry for microstructure linewidth measurement
    Totzeck, M
    Tiziani, HJ
    OPTICS LETTERS, 1999, 24 (05) : 294 - 296