Assessment of occupational radiation exposure during a specific endoscopic retrograde cholangiopancreatography procedure

被引:0
|
作者
Abdi, Ahmed Jibril [1 ,2 ]
Pedersen, Malene Roland Vils [3 ,4 ]
Precht, Helle [3 ,5 ,6 ]
Brage, Karen [5 ,7 ]
Hansen, Pernille Lund [5 ,7 ]
机构
[1] Odense Univ Hosp, Dept Clin Engn, JB Winslows Vej 4, DK-5000 Odense C, Region Of South, Denmark
[2] Univ Southern Denmark, Res & Innovat Unit Radiol, Klovervaenget 10, DK-5000 Odense C, Denmark
[3] Univ Southern Denmark, Dept Reg Hlth Res, Campusvej 55, DK-5230 Odense M, Denmark
[4] Vejle Hosp, Dept Radiol, Beriderbakken 4, Vejle, Denmark
[5] UCL Univ Coll, Hlth Sci Res Ctr, Niels Bohrs 1, DK-5230 Odense M, Denmark
[6] Univ Hosp Southern Denmark, Lillebaelt Hosp, Dept Radiol, Sygehusvej 24, Kolding, Denmark
[7] UCL Univ Coll, Educ Radiog, Niels Bohrs 1, DK-5230 Odense M, Denmark
关键词
PROTECTION; ERCP; STAFF;
D O I
10.1093/rpd/ncae197
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Aim The aim of this study was to evaluate the occupational radiation exposure of staff during endoscopic retrograde cholangiopancreatography (ERCP), with a focus on individuals closest to the radiation source, and to identify potential increases in exposure to hands and eye lenses. Patient radiation exposure during ERCP was also assessed.Materials and methods Staff organ doses were monitored using a Philips Allura Xper FD 20 fluoroscopy system, during 24 ERCP procedures for a period of 7 months. Staff doses were measured using thermoluminescence dosemeters and electronic personal dosemeters, and patient effective doses were simulated and calculated.Results Physicians' annual organ doses ranged from 0.2 to 1.6 mSv for shoulders, 0.1 to 0.4 mSv for eye lenses, and 0.3 to 1.6 mSv for fingers. The annual organ dose of the nursing staff ranged from 0.08 to 2.4 mSv for shoulders, 0.02 to 2.3 mSv for eye lenses, and 1.2 to 5.3 mSv for fingers. The effective dose to patients ranged from 0.009 to 0.46 mSv.Conclusion Staff doses were within safe limits, but patient doses were high, emphasizing the need for improved radiation protection.
引用
收藏
页码:1902 / 1910
页数:9
相关论文
共 50 条
  • [31] Radiation exposure during image-guided endoscopic procedures: The next quality indicator for endoscopic retrograde cholangiopancreatography
    Hayashi, Shiro
    Takenaka, Mamoru
    Hosono, Makoto
    Nishida, Tsutomu
    WORLD JOURNAL OF CLINICAL CASES, 2018, 6 (16) : 1087 - 1093
  • [32] Radiation exposure during image-guided endoscopic procedures: The next quality indicator for endoscopic retrograde cholangiopancreatography
    Shiro Hayashi
    Mamoru Takenaka
    Makoto Hosono
    Tsutomu Nishida
    World Journal of Clinical Cases, 2018, (16) : 1087 - 1093
  • [33] Assessment of radiation doses received by patients during endoscopic retrograde cholangiopancreatography according to disease location
    del Olmo Martinez, Lourdes
    Velayos Jimenez, Benito
    Munoz Moreno, Maria Fe
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2021, 113 (07) : 500 - 504
  • [34] Effects of a Brief Educational Program on Optimization of Fluoroscopy to Minimize Radiation Exposure During Endoscopic Retrograde Cholangiopancreatography
    Barakat, Monique T.
    Thosani, Nirav C.
    Huang, Robert J.
    Choudhary, Abhishek
    Kochar, Rajan
    Kothari, Shivangi
    Banerjee, Subhas
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2018, 16 (04) : 550 - 557
  • [35] Eye lens exposure to medical staff during endoscopic retrograde cholangiopancreatography
    Zagorska, A.
    Romanova, K.
    Hristova-Popova, J.
    Vassileva, J.
    Katzarov, K.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 781 - 784
  • [36] Radiation exposure in therapeutic endoscopic retrograde cholangiopancreatography with two types of fluoroscopy systems
    Wang, Yao-Sheng
    Wu, Ying-Jung
    Tseng, Wan-Jou
    Huang, Chien-Jui
    Chen, Chiung-Yu
    ADVANCES IN DIGESTIVE MEDICINE, 2024,
  • [37] Reduction of radiation doses to patients and staff during endoscopic retrograde cholangiopancreatography
    Sulieman, Abdelmoneim
    Paroutoglou, Georgios
    Kapsoritakis, Andreas
    Kapatenakis, Anargeyros
    Potamianos, Spiros
    Vlychou, Marianna
    Theodorou, Kiki
    SAUDI JOURNAL OF GASTROENTEROLOGY, 2011, 17 (01): : 23 - 29
  • [38] Assessment of patient dose and radiogenic risks during endoscopic retrograde cholangiopancreatography
    Sulieman, A.
    Elzaki, M.
    Alkhorayef, M.
    Babikir, E.
    Abuzaid, M.
    Dalton, A.
    Bradley, D.
    APPLIED RADIATION AND ISOTOPES, 2016, 117 : 65 - 69
  • [39] Patient Radiation Exposure during Enteroscopy-Assisted Endoscopic Retrograde Cholangiopancreatography in Surgically Altered Anatomy (with Video)
    Monino, Laurent
    Moreels, Tom G.
    DIAGNOSTICS, 2024, 14 (02)
  • [40] Long-term follow-up after fetal radiation exposure during endoscopic retrograde cholangiopancreatography
    Laudanno, Oscar
    Garrido, Jose
    Ahumaran, Gabrial
    Gollo, Pablo
    Khoury, Marina
    ENDOSCOPY INTERNATIONAL OPEN, 2020, 08 (12) : E1909 - E1914