Conversion of single circuit AC transmission lines to bipolar DC

被引:0
|
作者
Karaca, Eda [1 ]
Nuroglu, Fatih Mehmet [1 ]
机构
[1] Karadeniz Tech Univ, Dept Elect & Elect Engn, Trabzon, Turkiye
关键词
electric field; transmission lines; audible noise; HVDC; HVAC;
D O I
10.1109/GPECOM61896.2024.10582706
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Growing population rates drive the demand for housing and electricity. Over time, houses could be built in close proximity to previously installed overhead lines. Transmission lines pose a danger to living beings due to the electromagnetic field they emit. The transmission of electricity through high-voltage DC lines is one of the new technologies being used in the world thanks to its advantages such as the ability to carry more energy with reduced loss. This study aimed to measure the electric field and audible noise generated at ground level by 400 kV AC single circuit lines operating as bipolar DC in the Turkish electricity transmission system.
引用
收藏
页码:322 / 327
页数:6
相关论文
共 50 条
  • [31] Bidirectional Power Conversion by DC-AC Converter with Active Clamp Circuit
    Anusha, H.
    Kumar, S. B. Naveen
    EMERGING RESEARCH IN ELECTRONICS, COMPUTER SCIENCE AND TECHNOLOGY, ICERECT 2018, 2019, 545 : 1283 - 1294
  • [32] Design of the inner AC circuit of a DC hub for the interconnection of multiple HVDC lines
    Poikilidis, Michalis
    Kontos, Epameinondas
    Bauer, Pavol
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 1670 - 1677
  • [33] Influence of AC transmission lines on parallelly erected ±500 kV HVDC double circuit transmission lines and suppression measure
    Li, Tao
    Li, Xin-Nian
    Jiang, Wei-Ping
    Gao, Jian
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (19): : 70 - 75
  • [34] Corona loss analysis of high voltage DC transmission lines in close proximity of high voltage AC transmission lines
    Beijing Key Laboratory on High Voltage and EMC , Changping District, Beijing 102206, China
    Zhongguo Dianji Gongcheng Xuebao, 31 (211-218):
  • [35] Single-phase Dynamic Voltage Restorer Based on Bipolar Direct AC/AC Conversion
    Wang Y.
    Cai G.
    Liu C.
    Guo D.
    Wang P.
    Zhu B.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (06): : 171 - 177
  • [36] A Novel Single-Terminal Fault Location Method for AC Transmission Lines in a MMC-HVDC-Based AC/DC Hybrid System
    Xue, Shimin
    Lu, Junchi
    Liu, Chong
    Sun, Yabing
    Liu, Baibing
    Gu, Cheng
    ENERGIES, 2018, 11 (08):
  • [37] Ion-Flow Field Calculations of AC/DC Hybrid Transmission Lines
    Straumann, Ueli
    Franck, Christian M.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (01) : 294 - 302
  • [38] Power Enhancement of Transmission Lines by Combining AC and DC by using MATLAB/SILULINK
    Shinde, Minakshi R.
    Naik, A. V.
    2016 INTERNATIONAL CONFERENCE ON ENERGY EFFICIENT TECHNOLOGIES FOR SUSTAINABILITY (ICEETS), 2016, : 554 - 559
  • [39] Some Aspects of Steady State Simulations of AC/DC Hybrid Transmission Lines
    Novitskiy, Alexander
    Westermann, Dirk
    2017 1ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2017 17TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2017,
  • [40] Research on lightning performance of AC/DC hybrid transmission lines on the same tower
    Shi Wei
    Li Qingmin
    Zou Liang
    Zhang Li
    Lu Xinchang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (02) : 166 - 174