Feasibility study on atrial fibrillation ablation with pulsed field ablation and concomitant occlusion of the left atrial appendage

被引:1
|
作者
Beney, Jennifer [1 ]
Galea, Roberto [1 ]
Siontis, Georgios [1 ]
Graeni, Christoph [1 ]
Kueffer, Thomas [1 ]
Brugger, Nicolas [1 ]
Reichlin, Tobias [1 ]
Raeber, Lorenz [1 ]
Roten, Laurent [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Inselspital, Dept Cardiol, Freiburgstr, CH-3010 Bern, Switzerland
来源
EUROPACE | 2024年 / 26卷 / 07期
关键词
Atrial fibrillation; Catheter ablation; Left atrial appendage occlusion; Pulmonary vein isolation; Pulsed field ablation; CATHETER ABLATION; CLOSURE; SAFETY; OUTCOMES; IMPLANT; SUCCESS; IMPACT;
D O I
10.1093/europace/euae176
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Atrial fibrillation (AF) ablation and left atrial appendage occlusion (LAAO) are increasingly performed as individual procedures. Pulsed field ablation (PFA) has significantly reduced procedure duration and may be advantageous for the combined approach.Methods and results We have launched a programme for simultaneous AF ablation using PFA and LAAO for patients qualifying for both treatments and excluding those with a complex anatomy. We compare procedure duration and fluoroscopy time against individual procedures (either AF ablation or LAAO alone), all performed by the same operators and using consistent technologies. We performed the combined procedure in 10 patients (50% males; median age 70 years) and excluded 2 patients (17%) because of a complex left atrial appendage anatomy. No death, stroke, or major bleeding events, including pericardial effusion, occurred. For single-procedure comparison, 207 AF ablation procedures and 61 LAAO procedures were available. The total median procedure duration was 79 min (range 60-125) for the combined procedure, 71 min (25-241) for individual AF ablation (51 min without and 78 min with 3-dimensional electroanatomic mapping), and 47 min (15-162) for individual LAAO. The respective fluoroscopy times were 21 (15-26), 15 (5-44), and 10 (3-50) min. For the combined procedure, femoral vein access to last PFA application lasted 49 min (34-93) and LAAO added 20 min (15-37).Conclusion Simultaneous PFA-based AF ablation and LAAO in carefully selected patients is feasible and safe and can be executed within a short overall procedure duration. Graphical Abstract
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Is Ablation of Atrial Fibrillation in Patients With Chronic Left Atrial Appendage Thrombus Safe?
    Di Biase, Luigi
    Burkhardt, J. David
    Sanchez, Javier
    Hongo, Richard
    Horton, Rodney
    Gallinghouse, Joseph G.
    Beheiry, Salwa
    Hao, Steven
    Mohanty, Prasant
    Mohanty, Sanghamitra
    Conti, Sergio
    Bai, Rong
    Lakkireddy, Dhanunjay
    Lewis, William R.
    Schweikert, Robert A.
    Natale, Andrea
    CIRCULATION, 2010, 122 (21)
  • [42] Cryoballoon ablation with sequential left atrial appendage closure for the treatment of atrial fibrillation
    Hao Zhang
    中国循环杂志, 2018, (S1) : 156 - 157
  • [43] Catheter ablation for atrial fibrillation in patients with Left atrial appendage closure devices
    Callans, David J.
    HEART RHYTHM, 2015, 12 (07) : 1532 - 1533
  • [44] Combination of left atrial appendage closure with catheter ablation for the treatment of atrial fibrillation
    Kai, Tang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C119 - C120
  • [45] Masked Left Atrial Appendage Isolation During Ablation of Persistent Atrial Fibrillation
    Leftheriotis, Dionyssios
    Ouyang, Feifan
    HEART RHYTHM, 2011, 8 (02) : E1 - E2
  • [46] Morphological changes of the left atrial appendage after catheter ablation of atrial fibrillation
    Chang, Sheng-Hsiung
    Tsao, Hsuan-Ming
    Wu, Mei-Han
    Tai, Ching-Tai
    Chang, Shih-Lin
    Wongcharoen, Wanwarang
    Lin, Yenn-Jiang
    Lo, Li-Wei
    Hsieh, Ming-Hsiung
    Sheu, Ming-Huei
    Chang, Cheng-Yen
    Jia-Yin, Charles
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (01) : 47 - 52
  • [47] Masked left atrial appendage isolation during ablation of persistent atrial fibrillation
    Leftheriotis, Dionyssios
    Yoshiga, Yasuhiro
    Kuck, Karl-Heinz
    Ouyang, Feifan
    HEART RHYTHM, 2011, 8 (01) : 137 - 141
  • [48] Insufficient Ablation is Associated with Atrial Fibrillation Recurrence after Combining Ablation and Left Atrial Appendage Closure
    Ding, Xueyan
    Zhao, Yao
    Dong, Shaohua
    Huang, Xinmiao
    Qin, Aihong
    Cao, Jiang
    Guo, Zhifu
    Huang, Songqun
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (01)
  • [49] Atrial fibrillation ablation combined with left atrial appendage occlusion: Optimal patient selection should be the main focus
    Letsas, Konstantinos P.
    Saplaouras, Athanasios
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 371 : 130 - 131
  • [50] Concurrent percutaneous left atrial appendage occlusion and catheter ablation for atrial fibrillation: State-of-the-art review
    Mills, Mark T.
    Calvert, Peter
    Velavan, Periaswamy
    Lip, Gregory Y. H.
    Gupta, Dhiraj
    TRENDS IN CARDIOVASCULAR MEDICINE, 2024, 34 (07) : 423 - 433