Development and validation of the surmising model for volumetric breast density using X-ray exposure conditions in digital mammography

被引:0
|
作者
Yamamuro, Mika [1 ]
Asai, Yoshiyuki [1 ]
Yamada, Takahiro [2 ]
Kimura, Yuichi [3 ]
Ishii, Kazunari [4 ]
Kondo, Yohan [5 ]
机构
[1] Kindai Univ Hosp, Radiol Ctr, 377-2 Osaka Sayama, Osaka 5898511, Japan
[2] Kindai Univ, Inst Adv Clin Med, Div Positron Emiss Tomog, 377-2 Ono Higashi, Osaka, Osaka 5898511, Japan
[3] Kindai Univ, Fac Informat, 3-4-1 Kowakae, Higashiosaka, Osaka 5778502, Japan
[4] Kindai Univ, Fac Med, Dept Radiol, 377-2 Ohnohigashi, Osaka, Osaka 5898511, Japan
[5] Niigata Univ, Grad Sch Hlth Sci, Asahimachi Dori,Chuo Ku, Niigata 9518518, Japan
基金
日本学术振兴会;
关键词
Breast density; Surmising model; Mammographic X-ray exposure conditions; Breast cancer biomarker;
D O I
10.1007/s11517-024-03186-w
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The use of breast density as a biomarker for breast cancer treatment has not been well established owing to the difficulty in measuring time-series changes in breast density. In this study, we developed a surmising model for breast density using prior mammograms through a multiple regression analysis, enabling a time series analysis of breast density. We acquired 1320 mediolateral oblique view mammograms to construct the surmising model using multiple regression analysis. The dependent variable was the breast density of the mammary gland region segmented by certified radiological technologists, and independent variables included the compressed breast thickness (CBT), exposure current times exposure second (mAs), tube voltage (kV), and patients' age. The coefficient of determination of the surmising model was 0.868. After applying the model, the correlation coefficients of the three groups based on the CBT (thin group, 18-36 mm; standard group, 38-46 mm; and thick group, 48-78 mm) were 0.913, 0.945, and 0.867, respectively, suggesting that the thick breast group had a significantly low correlation coefficient (p = 0.00231). In conclusion, breast density can be accurately surmised using the CBT, mAs, tube voltage, and patients' age, even in the absence of a mammogram image.
引用
收藏
页码:169 / 179
页数:11
相关论文
共 50 条
  • [41] Optimization of breast cancer detection in Dual Energy X-ray Mammography using a CMOS imaging detector
    Koukou, V.
    Fountos, G.
    Martini, N.
    Sotiropoulou, P.
    Michail, C.
    Kalyvas, N.
    Valais, I.
    Bakas, A.
    Kounadi, E.
    Kandarakis, I.
    Nikiforidis, G.
    3RD INTERNATIONAL CONFERENCE ON MATHEMATICAL MODELING IN PHYSICAL SCIENCES (IC-MSQUARE 2014), 2015, 574
  • [42] Experimental validation of a radiographic simulation code using breast phantom for X-ray imaging
    Bliznakova, K.
    Speller, R.
    Horrocks, J.
    Liaparinos, P.
    Kolitsi, Z.
    Pallikarakis, N.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2010, 40 (02) : 208 - 214
  • [43] Pediatric evaluation using dual-energy X-ray absorptiometry: volumetric density is unwarranted.
    Barden, HS
    Mazess, RB
    Hanson, JA
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 : S221 - S221
  • [44] Validation of ablation model for polyethylene using pulsed x-ray and proton exposures
    Moore, N. W.
    Sanchez, J. J.
    Schaeuble, M. -A.
    Hinshelwood, D.
    Harvey-Thompson, A.
    Myers, C. E.
    Jones, B.
    Franke, B. C.
    JOURNAL OF APPLIED PHYSICS, 2022, 132 (23)
  • [45] Early Detection of Breast Cancer Using Stationary Digital Breast Tomosynthesis with Quasimonochromatic X-ray Sources
    Qian, X.
    Tang, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : S168 - S168
  • [46] Development of Fluorescence XAFS System in Soft X-Ray Region Toward Operando Conditions Using Polycapillary X-Ray Lens
    Honda, Mitsunori
    Shimoyama, Iwao
    Baba, Yuji
    Suzuki, Shinichi
    Okamoto, Yoshihiro
    Yaita, Tsuyoshi
    E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2016, 14 : 35 - 38
  • [47] The possibility of using x-ray diffraction with hair to screen for pathologic conditions such as breast cancer
    James, V
    Cookson, D
    X-RAY AND INNER-SHELL PROCESSES, 2000, 506 : 590 - 594
  • [48] Storage-phosphor-based digital mammography using a low-dose x-ray system optimized for screen-film mammography
    Jennings, RJ
    Jafroudi, H
    Gagne, RM
    Fewell, TR
    Quinn, PW
    Artz, DES
    Vucich, JJ
    Freedman, MT
    Mun, SK
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 220 - 232
  • [49] Prospects for x-ray exposure reduction using digital radiography with a flat-panel detector
    Okusako, K
    Hatagawa, M
    Kishimoto, K
    Tanaka, K
    Kudo, H
    Yamada, R
    RADIOLOGY, 2001, 221 : 158 - 158
  • [50] Discrete and continuum analysis of localised deformation in sand using X-ray μCT and volumetric digital image correlation
    Hall, S. A.
    Bornert, M.
    Desrues, J.
    Pannier, Y.
    Lenoir, N.
    Viggiani, G.
    Besuelle, P.
    GEOTECHNIQUE, 2010, 60 (05): : 315 - 322