Conductometric H2S Sensors Based on TiO2 Nanoparticles

被引:1
|
作者
Alaya, Yassine [1 ]
Madani, Malek [1 ]
Bouguila, Noureddine [1 ]
El Mir, Lassaad [1 ]
Fazio, Enza [2 ]
Corsaro, Carmelo [2 ]
Neri, Giovanni [3 ]
机构
[1] Gabes Univ, Fac Sci Gabes, Lab Phys Mat & Nanomat Appl Environm LaPhyMNE, Gabes 6072, Tunisia
[2] Univ Messina, Dept Math & Comp Sci Phys Sci & Earth Sci, Viale F Stagno Alcontres 31, I-98166 Messina, Italy
[3] Univ Messina, Dept Engn, Cda Di Dio, I-98166 Messina, Italy
关键词
sol-gel; TiO2; nanopowder; thermal treatment; H2S sensor; OPTICAL CHARACTERIZATION; SENSING PERFORMANCE; THIN-FILMS; OXIDE; SENSITIVITY; COMPOSITES; ZNO;
D O I
10.3390/ma17133283
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
High-performance hydrogen sulfide (H2S) sensors are mandatory for many industrial applications. However, the development of H2S sensors still remains a challenge for researchers. In this work, we report the study of a TiO2-based conductometric sensor for H2S monitoring at low concentrations. TiO2 samples were first synthesized using the sol-gel route, annealed at different temperatures (400 and 600 degrees C), and thoroughly characterized to evaluate their morphological and microstructural properties. Scanning electronic microscopy, Raman scattering, X-ray diffraction, and FTIR spectroscopy have demonstrated the formation of clusters of pure anatase in the TiO2 phase. Increasing the calcination temperature to 600 degrees C enhanced TiO2 crystallinity and particle size (from 11 nm to 51 nm), accompanied by the transition to the rutile phase and a slight decrease in band gap (3.31 eV for 400 degrees C to 3.26 eV for 600 degrees C). Sensing tests demonstrate that TiO2 annealed at 400 degrees C displays good performances (sensor response Ra/Rg of similar to 3.3 at 2.5 ppm and fast response/recovery of 8 and 23 s, respectively) for the detection of H2S at low concentrations in air.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Gas-phase photocatalytic destruction of H2S using UV/TiO2
    Jardim, WD
    Huang, CP
    CHEMICAL OXIDATION: TECHNOLOGIES FOR THE NINETIES, VOL 6, 1997, : 254 - 259
  • [32] A low operating temperature and high performance sensor for H2S detection based on α-Fe2O3/TiO2 heterojunction nanoparticles composite
    Xu, Zhiwu
    Liu, Haixin
    Tong, Xin
    Shen, Wenhao
    Chen, Xiaoquan
    Bloch, Jean-Francis
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2019, 30 (13) : 12695 - 12709
  • [33] A low operating temperature and high performance sensor for H2S detection based on α-Fe2O3/TiO2 heterojunction nanoparticles composite
    Zhiwu Xu
    Haixin Liu
    Xin Tong
    Wenhao Shen
    Xiaoquan Chen
    Jean-Francis Bloch
    Journal of Materials Science: Materials in Electronics, 2019, 30 : 12695 - 12709
  • [34] Comparison of Photocatalytic Activities of Cu/TiO2 and Ag/TiO2 in Gaseous- and Liquid-Phases Degradation of H2S
    Tamura, Ryosuke
    Ochiai, Tsuyoshi
    Aoki, Daisuke
    Saito, Hidenori
    Nagata, Morio
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2017, 9 (11) : 1696 - 1699
  • [35] Quartz Crystal Microbalance sensors based on TiO2 nanoparticles for gas sensing
    Addabbo, Tommaso
    Fort, Ada
    Mugnaini, Marco
    Tani, Marco
    Vignoli, Valerio
    Bruzzi, Mara
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1639 - 1644
  • [36] Humidity sensors based on TiO2 nanoparticles/polypyrrole composite thin films
    Su, Pi-Guey
    Huang, Lin-Nan
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) : 501 - 507
  • [37] Quartz-Crystal Microbalance Gas Sensors Based on TiO2 Nanoparticles
    Addabbo, Tommaso
    Fort, Ada
    Mugnaini, Marco
    Vignoli, Valerio
    Baldi, Andrea
    Bruzzi, Mara
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (03) : 722 - 730
  • [38] Development and characterization of electrochemical sensors based on carbon modified with TiO2 nanoparticles
    Micin, Sasa
    Malinovic, Borislav N.
    Duricic, Tijana
    HEMIJSKA INDUSTRIJA, 2022, 76 (03) : 147 - 158
  • [39] NANOCRYSTALLINE WO3-BASED H2S SENSORS
    LIN, HM
    HSU, CM
    YANG, HY
    LEEB, PY
    YANG, CC
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 22 (01) : 63 - 68
  • [40] DSCs based on TiO2 nanoparticles
    不详
    INDUSTRIAL CERAMICS, 2005, 25 (02): : 141 - 141