Techno-economic analysis of deploying a short or mixed energy storage strategy in a 100 % green power grid

被引:0
|
作者
Cui, John Zhehao [1 ]
Xie, Chunping [1 ,2 ]
Wu, Wei [3 ]
Widijatmoko, Samuel D. [4 ]
Hong, Yan [4 ]
Li, Yongliang [4 ]
Leeke, Gary A. [4 ]
机构
[1] LSE, Grantham Res Inst Climate Change & Environm, 32 Lincolns Inn Fields, London WC2A 3PH, England
[2] Asian Infrastruct Investment Bank, Econ Dept, Beijing 100101, Peoples R China
[3] Xiamen Univ, Inst Psychol, Xiamen 361005, Peoples R China
[4] Univ Birmingham, Sch Chem Engn, Birmingham B15 2TT, England
基金
英国工程与自然科学研究理事会;
关键词
Long-duration energy storage; Fully green electricity grid; Renewable energy systems; Lithium-ion battery; Hydrogen; Electric thermal energy storage; BATTERIES;
D O I
10.1016/j.est.2024.113333
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A fully decarbonised electricity grid with extensively deployed renewable systems is a fundamental step in transitioning to a net-zero world. Unlike fossil energy, renewable energy systems are subject to meteorological intermittency. However, few studies have investigated the techno-economic performance of integrating shortand promising long-duration energy storage into a 100% renewable energy grid to balance short-term and interseasonal demand. This research developed an economic model to investigate the techno-economic performance of standalone and combined energy storage solutions for a fully green grid in three defined scenarios. Lithium-ion batteries (Liion), hydrogen, and electrical thermal energy storage (ETES) were selected as promising storage technologies due to their maturity, commercial availability, and scalability. The three examined scenarios are: 1) Li-ion battery only, 2) Li-ion battery with ETES, and 3) Li-ion battery with hydrogen. The research aims to determine whether combining long-duration energy storage (e.g., ETES and hydrogen) with Li-ion batteries offers greater economic and technical benefits, resulting in a more affordable, resilient, and secure power supply. The results show that the Li-ion battery only scenario (Scenario 1) requires a capacity of 234,956 MWh. Adding ETES and hydrogen reduces this capacity to 53,304 MWh (Scenario 2) and 7020 MWh (Scenario 3). The addition of ETES and hydrogen improves power supply flexibility, increasing the proportion of generated electricity used to meet demand from 32.7 % in Scenario 1 to 41.2 % and 52.3 % in Scenarios 2 and 3, respectively. These technologies also help avoid electricity deficits, reduce the loss of power probability (LOPP), and lower the cost of electricity supply losses from $8365 million in Scenario 1 to $1793 million in Scenario 2 and only $4 million in Scenario 3. Power delivery costs decrease from $99.5/MWh in Scenario 1 to $77.6/MWh and $76.6/MWh in Scenarios 2 and 3, respectively. The research concludes with four policy recommendations to advance long-duration energy storage and transition to a fully green power supply system.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] TECHNO-ECONOMIC ANALYSIS OF EMERGING ENERGY STORAGE TECHNOLOGIES FOR A MICROGRID
    Schmitt, Joshua
    Hofer, Douglas
    Pryor, Owen
    Khawly, George
    Bulnes, Fernando Karg
    McClung, Aaron
    PROCEEDINGS OF ASME TURBO EXPO 2024: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2024, VOL 6, 2024,
  • [22] Techno-economic and social analysis of energy storage for commercial buildings
    Yan, Xiaohui
    Zhang, Xuehui
    Chen, Haisheng
    Xu, Yujie
    Tan, Chunqing
    ENERGY CONVERSION AND MANAGEMENT, 2014, 78 : 125 - 136
  • [23] Hydrogen underground storage for grid electricity storage: An optimization study on techno-economic analysis
    Chen, Yunzhi
    Hill, Daniel
    Billings, Blake
    Hedengren, John
    Powell, Kody
    ENERGY CONVERSION AND MANAGEMENT, 2024, 322
  • [24] Hybrid Power System for off-grid Communities: Techno-economic and Energy Mix Analysis
    Babatunde, O. M.
    Emezirinwune, M. U.
    Denwigwe, I. H.
    Akin-Adeniyi, J. T.
    2017 IEEE 3RD INTERNATIONAL CONFERENCE ON ELECTRO-TECHNOLOGY FOR NATIONAL DEVELOPMENT (NIGERCON), 2017, : 946 - 952
  • [25] Techno-economic analysis of off-grid renewable energy power station: A case study
    Liu Liqun
    Liu Chunxia
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (7A): : 94 - 98
  • [26] Energy storage sizing and enhanced dispatch strategy with temperature and safety considerations: A techno-economic analysis
    Faruhaan, Abdulla
    Go, Yun Ii
    ENERGY STORAGE, 2021, 3 (06)
  • [27] Techno-Economic Feasibility Analysis of On-Grid Battery Energy Storage System: Almanara PV Power Plant Case Study
    Arfoa, Aouda A.
    Almaita, Eyad
    Alshkoor, Saleh
    Shloul, Maan
    JORDAN JOURNAL OF ELECTRICAL ENGINEERING, 2022, 8 (03): : 253 - 265
  • [28] Techno-economic analysis of hydrogen energy for renewable energy power smoothing
    Kong, Lingguo
    Li, Linagyuan
    Cai, Guowei
    Liu, Chuang
    Ma, Ping
    Bian, Yudong
    Ma, Tao
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (03) : 2847 - 2861
  • [29] Sizing and techno-economic analysis of a grid connected photovoltaic system with hybrid storage
    Bensmaine, Faycal
    Abbes, Dhaker
    Labrunie, Antoine
    Robyns, Benoit
    2016 51ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2016,
  • [30] Techno-economic analysis of an autonomous power system integrating hydrogen technology as energy storage medium
    Tzamalis, G.
    Zoulias, E. I.
    Stamatakis, E.
    Varkaraki, E.
    Lois, E.
    Zannikos, F.
    RENEWABLE ENERGY, 2011, 36 (01) : 118 - 124