Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study

被引:4
|
作者
Shusterman, Ariel
Nashef, Rizan [1 ]
Tecco, Simona [2 ]
Mangano, Carlo [2 ]
Lerner, Henriette [3 ]
Mangano, Francesco Guido [4 ]
机构
[1] Shaare Zedek Med Ctr, Oral & Maxillofacial Surg Unit, Jerusalem, Israel
[2] San Raffaele Univ, Dept Dent Sci, Milan, Italy
[3] Goethe Univ Frankfurt, Acad Teaching & Res Inst, Frankfurt, Germany
[4] IM Sechenov First State Med Univ, Dept Pediat Prevent Dent & Orthodont, Moscow, Russia
关键词
Guided implant surgery; Static guided implant surgery; Freehand implant placement; Mixed reality; Holograms; accuracy;
D O I
10.1016/j.jdent.2024.105052
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This in vitro study aimed to compare the accuracy of dental implant placement in partially edentulous maxillary models using a mixed reality-based dynamic navigation (MR-DN) system to conventional static computer-assisted implant surgery (s-CAIS) and a freehand (FH) method. Methods: Forty-five partially edentulous models (with teeth missing in positions #15, #16 and #25) were assigned to three groups (15 per group). The same experienced operator performed the model surgeries using an MR-DN system (group 1), s-CAIS (group 2) and FH (group 3). In total, 135 dental implants were placed (45 per group). The primary outcomes were the linear coronal deviation (entry error; En), apical deviation (apex error; Ap), XY and Z deviations, and angular deviation (An) between the planned and actual (post-surgery) position of the implants in the models. These deviations were computed as the distances between the stereolithographic (STL) files for the planned implants and placed implants captured with an intraoral scanner. Results: Across the three implant sites, the MR-DN system was significantly more accurate than the FH method (in XY, Z, En, Ap and An) and s-CAIS (in Z, Ap and An), respectively. However, S-CAIS was more accurate than MRDN in XY, and no difference was found between MR-DN and s-CAIS in En. Conclusions: Within the limits of this study (in vitro design, only partially edentulous models), implant placement accuracy with MR-DN was superior to that of FH and similar to that of s-CAIS. Statement of Clinical Relevance: In vitro, MR-DN showed greater accuracy in implant positioning than FH, and similar accuracy to s-CAIS: it could, therefore, represent a new option for the surgeon. However, clinical studies are needed to determine the feasibility of MR-DN.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Effect of Clinical Experience on Accuracy of Implant Placement Using Dynamic Navigation and Static Guidance: An In Vitro Study
    Fang, Qiao
    Lozada, Jaime
    Kan, Joseph
    Al-Ardah, Aladdin
    Li, Yiming
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (06) : 626 - 635
  • [32] Accuracy of dynamic navigation compared to static surgical guides and the freehand approach in implant placement: a prospective clinical study
    Younis, Hamza
    Lv, Chengpeng
    Xu, Boya
    Zhou, Huixia
    Du, Liangzhi
    Liao, Lifan
    Zhao, Ningbo
    Long, Wen
    Elayah, Sadam Ahmed
    Chang, Xiaofeng
    He, Longlong
    HEAD & FACE MEDICINE, 2024, 20 (01)
  • [33] Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial
    Edelmann, Cornelia
    Wetzel, Martin
    Knipper, Anne
    Luthardt, Ralph G.
    Schnutenhaus, Sigmar
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [34] Seating accuracy of implant immediate provisional prostheses fabricated by digital workflow prior to implant placement by fully guided static computer-assisted implant surgery: An in vitro study
    Abduo, Jaafar
    Lau, Douglas
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (05) : 608 - 618
  • [35] The influence of radiographic marker registration versus a markerless trace registration method on the implant placement accuracy achieved by dynamic computer-assisted implant surgery. An in-vitro study
    Jorba-Garcia, Adria
    Bara-Casaus, Jose Javier
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    JOURNAL OF DENTISTRY, 2024, 146
  • [36] Accuracy of immediate anterior implantation using static and robotic computer-assisted implant surgery: A retrospective study
    Li, Jun
    Dai, Meng
    Wang, Siwei
    Zhang, Xitao
    Fan, Qin
    Chen, Lin
    JOURNAL OF DENTISTRY, 2024, 148
  • [37] Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study
    Li, Ping
    Zhao, Chunhui
    Chen, Jiahao
    Xu, Shulan
    Yang, Shuo
    Li, An
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1279 - 1288
  • [38] A Projector-Based Augmented Reality Navigation System for Computer-Assisted Surgery
    Gao, Yuan
    Zhao, Yuyun
    Xie, Le
    Zheng, Guoyan
    SENSORS, 2021, 21 (09)
  • [39] Accuracy of static computer-assisted implant placement in anterior and posterior sites by clinicians new to implant dentistry: in vitro comparison of fully guided, pilot-guided, and freehand protocols
    Jaafar Abduo
    Douglas Lau
    International Journal of Implant Dentistry, 6
  • [40] Accuracy of static computer-assisted implant placement in anterior and posterior sites by clinicians new to implant dentistry: in vitro comparison of fully guided, pilot-guided, and freehand protocols
    Abduo, Jaafar
    Lau, Douglas
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)