Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study

被引:4
|
作者
Shusterman, Ariel
Nashef, Rizan [1 ]
Tecco, Simona [2 ]
Mangano, Carlo [2 ]
Lerner, Henriette [3 ]
Mangano, Francesco Guido [4 ]
机构
[1] Shaare Zedek Med Ctr, Oral & Maxillofacial Surg Unit, Jerusalem, Israel
[2] San Raffaele Univ, Dept Dent Sci, Milan, Italy
[3] Goethe Univ Frankfurt, Acad Teaching & Res Inst, Frankfurt, Germany
[4] IM Sechenov First State Med Univ, Dept Pediat Prevent Dent & Orthodont, Moscow, Russia
关键词
Guided implant surgery; Static guided implant surgery; Freehand implant placement; Mixed reality; Holograms; accuracy;
D O I
10.1016/j.jdent.2024.105052
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This in vitro study aimed to compare the accuracy of dental implant placement in partially edentulous maxillary models using a mixed reality-based dynamic navigation (MR-DN) system to conventional static computer-assisted implant surgery (s-CAIS) and a freehand (FH) method. Methods: Forty-five partially edentulous models (with teeth missing in positions #15, #16 and #25) were assigned to three groups (15 per group). The same experienced operator performed the model surgeries using an MR-DN system (group 1), s-CAIS (group 2) and FH (group 3). In total, 135 dental implants were placed (45 per group). The primary outcomes were the linear coronal deviation (entry error; En), apical deviation (apex error; Ap), XY and Z deviations, and angular deviation (An) between the planned and actual (post-surgery) position of the implants in the models. These deviations were computed as the distances between the stereolithographic (STL) files for the planned implants and placed implants captured with an intraoral scanner. Results: Across the three implant sites, the MR-DN system was significantly more accurate than the FH method (in XY, Z, En, Ap and An) and s-CAIS (in Z, Ap and An), respectively. However, S-CAIS was more accurate than MRDN in XY, and no difference was found between MR-DN and s-CAIS in En. Conclusions: Within the limits of this study (in vitro design, only partially edentulous models), implant placement accuracy with MR-DN was superior to that of FH and similar to that of s-CAIS. Statement of Clinical Relevance: In vitro, MR-DN showed greater accuracy in implant positioning than FH, and similar accuracy to s-CAIS: it could, therefore, represent a new option for the surgeon. However, clinical studies are needed to determine the feasibility of MR-DN.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study
    Otaghsara, Seyedeh Sahar Taheri
    Joda, Tim
    Thieringer, Florian Markus
    JOURNAL OF DENTISTRY, 2023, 132
  • [2] Accuracy of freehand versus dynamic computer-assisted zygomatic implant placement: An in-vitro study
    Traboulsi-Garet, Bassel
    Jorba-Garcia, Adria
    Bara-Casaus, Javier
    Camps-Font, Octavi
    Valmaseda-Castellon, Eduard
    Figueiredo, Rui
    Sanchez-Garces, M. Angeles
    JOURNAL OF DENTISTRY, 2025, 155
  • [3] Accuracy of dental implant placement using augmented reality-based navigation, static computer assisted implant surgery, and the free-hand method: An in vitro study
    Kivovics, Marton
    Takacs, Anna
    Penzes, Dorottya
    Nemeth, Orsolya
    Mijiritsky, Eitan
    JOURNAL OF DENTISTRY, 2022, 119
  • [4] Evaluation of the Accuracy, Surgical Time, and Learning Curve of Freehand, Static, and Dynamic Computer-Assisted Implant Surgery in an In Vitro Study
    Werny, Joscha Gabriel
    Fan, Shengchi
    Diaz, Leonardo
    Al-Nawas, Bilal
    Sagheb, Keyvan
    Gielisch, Matthias
    Schiegnitz, Eik
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [5] Comparison of the accuracy of dental implant placement using dynamic and augmented reality-based dynamic navigation: An in vitro study
    Tao, Baoxin
    Fan, Xingqi
    Wang, Feng
    Chen, Xiaojun
    Shen, Yihan
    Wu, Yiqun
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 196 - 202
  • [6] Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study
    Zhou, Miao
    Zhou, Hui
    Li, Shu-Yi
    Zhu, Yi-Bo
    Geng, Yuan-Ming
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : 343 - 348
  • [7] Accuracy of flapless immediate implant placement in anterior maxilla using computer-assisted versus freehand surgery: A cadaver study
    Chen, Zhaozhao
    Li, Junying
    Sinjab, Khaled
    Mendonca, Gustavo
    Yu, Haiyang
    Wang, Hom-Lay
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1186 - 1194
  • [8] Accuracy of 3 calibration methods of computer-assisted dynamic navigation for implant placement: An in vitro study
    Pei, Xiyan
    Liu, Xiaoqiang
    Iao, Siniong
    Ma, Feifei
    Li, Hong
    Sun, Feng
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04): : 668 - 674
  • [9] Implant placement using mixed reality-based dynamic navigation: A proof of concept
    Shusterman, Ariel
    Nashef, Rizan
    Tecco, Simona
    Mangano, Carlo
    Mangano, Francesco
    JOURNAL OF DENTISTRY, 2024, 149
  • [10] Comparison of accuracy in freehand versus computer-assisted (dynamic and static) dental implant placement: A systematic review and meta-analysis
    Banerjee, Saurav
    Debnath, Anasua
    Paul, Priyanjali
    Banerjee, Tridib Nath
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2025, 25 (01): : 22 - 29