Susceptibility of hepato-splanchnic perfusion to intra-abdominal pressure in peritoneal dialysis patients

被引:0
|
作者
Ribitsch, Werner [1 ]
Lehner, Thomas A. [2 ]
Sauseng, Notburga [2 ]
Rosenkranz, Alexander R. [1 ]
Schneditz, Daniel [2 ]
机构
[1] Med Univ Graz, Dept Internal Med, Clin Div Nephrol, Auenbruggerpl 27, A-8036 Graz, Austria
[2] Med Univ Graz, Otto Loewi Res Ctr Vasc Biol Immunol & Inflammat, Div Physiol & Pathophysiol, Graz, Austria
关键词
Peritoneal dialysis; intra-abdominal pressure; peritoneal filling; hepato-splanchnic perfusion; cardiorenal syndrome; LIVER BLOOD-FLOW; HYPERTONIC-GLUCOSE; INDOCYANINE GREEN; CLINICAL-PRACTICE; HEART-FAILURE; HEMODIALYSIS; VOLUME;
D O I
10.1177/08968608241275922
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background:<bold> </bold>The impact of peritoneal filling on hepato-splanchnic perfusion during peritoneal dialysis has not been fully elucidated yet. Methods:<bold> </bold>Measurements were done in 20 prevalent peritoneal dialysis patients during a peritoneal equilibration test (PET) with 2L of standard dialysate. Data were obtained in the drained state at baseline (T-0), after instillation (T-1), and after 2 h of dwell time (T-2). Intra-abdominal pressure (IAP) was measured by Durand's approach. The hepatic clearance index (KI) of indocyanine-green (ICG) was determined as an indirect measure of hepato-splanchnic blood flow. Cardiac index (CI), heart rate (HR), and total peripheral resistance index (TPRI) were derived from continuous arterial pulse analysis. Fluid volume overload (VO) was evaluated by multifrequency bioimpedance analysis. Ejection fraction (EF) was obtained from echocardiographic examination. Results:<bold> </bold>IAP was 5.8 +/- 3.5 mmHg at baseline (T-0), rose to 9.4 +/- 2.8 mmHg after instillation of dialysate (T-1), and further to 9.7 +/- 2.8 mmHg after 2 h of dwell time (p < 0.001). KI slightly declined from 0.60 +/- 0.22 L/min/m(2) at T-0 to 0.53 +/- 0.15 L/min/m(2) at T-1 (p = 0.075), and returned to 0.59 +/- 0.22 L/min/m(2) at T-2 (p = 0.052). CI, HR, and TPRI did not change significantly. In five patients with an EF < 40% KI was significantly lower at T-1 (0.42 +/- 0.12 L/min/m(2); p = 0.039), and further decreased at T-2 (0.40 +/- 0.04 L/min/m(2); p = 0.016) compared to patients with normal EF (T-1: 0.58 +/- 0.15 L/min/m(2) and T-2: 0.67 +/- 0.22 L/min/m(2)). Conclusions: Overall, hepatic clearance of ICG as a marker of hepato-splanchnic blood flow is not affected by the filling of the peritoneal cavity.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] INTRA-ABDOMINAL PRESSURE
    ASPDEN, R
    CLINICAL BIOMECHANICS, 1988, 3 (01) : 48 - 48
  • [32] Intra-abdominal pressure measurement: validation of intragastric pressure as a measure of intra-abdominal pressure
    Turnbull, D.
    Webber, S.
    Hamnegard, C. H.
    Mills, G. H.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (05) : 628 - 634
  • [33] Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review
    Rosaleen Chun
    Andrew W Kirkpatrick
    Annals of Intensive Care, 2
  • [34] Abdominal perfusion pressure: A superior parameter in the assessment of intra-abdominal hypertension - Discussion
    Ivatury, RR
    Bergstein, JM
    Pasquale, MD
    Paul, BK
    Simon, RJ
    Cheatham, ML
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 49 (04): : 626 - 627
  • [35] Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review
    Chun, Rosaleen
    Kirkpatrick, Andrew W.
    ANNALS OF INTENSIVE CARE, 2012, 2
  • [36] Reliability of measurement techniques for the hepato-splanchnic region in multiple-trauma patients
    D. Kljucevsek
    L. Kompan
    European Journal of Trauma and Emergency Surgery, 2011, 37 : 577 - 581
  • [37] Vasopressin and nitroglycerin decrease portal and hepatic venous pressure and hepato-splanchnic blood flow
    Wisen, E.
    Svennerholm, K.
    Bown, L. S.
    Houltz, E.
    Rizell, M.
    Lundin, S.
    Ricksten, S. -E.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2018, 62 (07) : 953 - 961
  • [38] The Association of Intra-Abdominal Adhesions with Peritoneal Dialysis Catheter-Related Complications
    Qureshi, Mohammad Azfar
    Maierean, Serban
    Crabtree, John H.
    Clarke, Alix
    Armstrong, Sean
    Fissell, Rachel
    Jain, Arsh K.
    Jassal, Sarbjit V.
    Hu, Susie L.
    Kennealey, Peter
    Liebman, Scott
    Mccormick, Brendan
    Momciu, Bogdan
    Pauly, Robert P.
    Pellegrino, Beth
    Perl, Jeffrey
    Pirkle, James L.
    Plumb, Troy J.
    Seshasai, Rebecca
    Shah, Ankur
    Shah, Nikhil
    Shen, Jenny
    Singh, Gurmukteshwar
    Tennankore, Karthik
    Uribarri, Jaime
    Vasilevsky, Murray
    Yang, Robert
    Quinn, Robert R.
    Nadler, Ashlie
    Oliver, Matthew J.
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2024, 19 (04): : 472 - 482
  • [39] SIGNIFICANCE OF INTRA-ABDOMINAL PRESSURE IN SURGICAL PATIENTS
    KEDDIE, N
    NEILL, RWK
    BRITISH JOURNAL OF SURGERY, 1967, 54 (10) : 875 - &
  • [40] Intra-Abdominal Pressure in Patients with Morbid Obesity
    Todurov, I.
    Bilianskyi, L.
    Perekhrestenko, O.
    Kalashnikov, O.
    Kosiukhno, S.
    OBESITY SURGERY, 2013, 23 (08) : 1117 - 1118