Fabrication of Glucose Fluorescent Aptasensor Based on CdTe Quantum Dots

被引:1
|
作者
Bardajee, Ghasem Rezanejade [1 ]
Chahrogh, Afsaneh Rahimi [2 ]
Monfared, Aazam [2 ]
机构
[1] Shahid Beheshti Univ, Fac Chem & Petr Sci, Dept Polymer & Mat Chem, Tehran 1983963113, Iran
[2] Payame Noor Univ, Dept Chem, Tehran 193953697, Iran
关键词
Glucose; Aptasensor; CdTe Quantum Dots; Fluorescence; GOLD NANOPARTICLES; LIGAND;
D O I
10.1007/s10895-024-03885-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Diabetes is a chronic metabolic disease characterized by high blood glucose (or blood sugar) levels, which harms the heart, blood vessels, eyes, kidneys, and nerves over time. So, it is crucial to regularly control glucose concentration in biological fluids to check its targets, reduce unpleasant symptoms of high and low blood sugar, and avoid long-term diabetes complications. This study developed a simple, rapid, sensitive, and cost-effective fluorescence system for glucose determination. The fluorescent Aptasensor was fabricated using cadmium telluride quantum dots (CdTe QDs) modified with thioglycolic acid and functionalized with thiol-glucose-aptamer through ligand exchange. The thiol-glucose-aptamer interacted directly with CdTe QDs, increasing fluorescence intensity. However, it decreased when the target molecules of glucose were introduced. The structural and morphological characteristics of the Aptasensor were confirmed by various analytical methods such as UV-visible spectroscopy, Fourier-transform infrared spectroscopy (FT-IR), field emission scanning electron microscopy (FESEM), energy dispersive x-ray spectroscopy (EDX), transmission electron microscopy (TEM), atomic force microscopy (AFM), and dynamic light scattering (DLS). According to the typical Stern-Volmer equation, the relationship between fluorescent quenching and target concentration was linear with a detection limit (LOD) of 0.13 +/- 1.95 x 10(-11) mol L-1 and a relative standard deviation (RSD) of 1.05%. The Aptasensor demonstrated high specificity towards the target and stability over 28 days. Furthermore, it detected glucose in human serum and urine with a recovery rate of up to 99.74%. The results indicate that the fluorescent Aptasensor could be valuable in developing robust sensing technology for low-concentrated analytes.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Fabrication of CdTe Quantum Dots-Apoferritin Arrays for Detection of Melamine
    Le, Thi Hoa
    Kim, Ji Hyeon
    Park, Sang Joon
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2017, 17 (08) : 5193 - 5196
  • [42] Glutathione-capped CdTe quantum dots for the sensitive detection of glucose
    Yuan, Jipei
    Guo, Weiwei
    Yin, Jianyuan
    Wang, Erkang
    TALANTA, 2009, 77 (05) : 1858 - 1863
  • [43] Carbon Dots-based Fluorescent Aptasensor for Detection of Dimethoate Pesticide
    Lu, Ting-Ting
    Wang, Jin-Long
    Zhan, Xiang-Qiang
    Wu, Yuan-Gen
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (01) : 74 - 82
  • [44] Aptamer-based fluorescent detection of bisphenol A using nonconjugated gold nanoparticles and CdTe quantum dots
    Li, Ying
    Xu, Jingyue
    Wang, Luokai
    Huang, Yanjun
    Guo, Jiajia
    Cao, Xianyi
    Shen, Fei
    Luo, Yeli
    Sun, Chunyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 815 - 822
  • [45] Turn-on fluorescent cyanide sensor based on copper ion-modified CdTe quantum dots
    Shang, Li
    Zhang, Lihua
    Dong, Shaojun
    ANALYST, 2009, 134 (01) : 107 - 113
  • [46] A fluorescent probe for the detection of Hg2+ based on rhodamine derivative and modified CdTe quantum dots
    Zhang, Kun
    Zhang, JiMei
    RESEARCH ON CHEMICAL INTERMEDIATES, 2020, 46 (02) : 987 - 997
  • [47] A fluorescent probe for the detection of Hg2+ based on rhodamine derivative and modified CdTe quantum dots
    Kun Zhang
    JiMei Zhang
    Research on Chemical Intermediates, 2020, 46 : 987 - 997
  • [48] A sensitive fluorescent nanosensor for chloramphenicol based on molecularly imprinted polymer-capped CdTe quantum dots
    Amjadi, Mohammad
    Jalili, Roghayeh
    Manzoori, Jamshid L.
    LUMINESCENCE, 2016, 31 (03) : 633 - 639
  • [49] A sensitive ratiometric fluorescent sensor based on carbon dots and CdTe quantum dots for visual detection of biogenic amines in food samples
    Yan, Jianfeng
    Fu, Quanbin
    Zhang, Shikai
    Liu, Yu
    Shi, Xianbao
    Hou, Juying
    Duan, Junling
    Ai, Shiyun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 282
  • [50] Composite molecularly imprinted ratiometric fluorescent sensor based on carbon dots and CdTe quantum dots for visual detection of ciprofloxacin in seawater
    Wang, Na
    Majid, Abdul
    Wang, Kunpeng
    Tan, Liju
    Li, Huiru
    Wang, Jiangtao
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2023, 167