Effect of flange widths of T-type PBL shear connectors on the mechanical performance in negative bending moment region of steel-concrete composite beams

被引:1
|
作者
Huang, Wenfeng [1 ]
Zhan, Yulin [1 ,3 ]
Li, Junyi [1 ]
Wu, Haoming [1 ]
Xu, Jianghui [1 ]
Shao, Junhu [1 ,2 ]
机构
[1] Southwest Jiaotong Univ, Dept Bridge Engn, Chengdu 610031, Peoples R China
[2] Chengdu Univ, Sch Architecture & Civil Engn, Chengdu 610106, Peoples R China
[3] Southwest Jiaotong Univ, Inst Civil Engn Mat, Chengdu 610031, Peoples R China
关键词
Steel-concrete composite beam; T-type perfobond rib shear connector; Negative bending moment region; Finite element analysis; Bending-bearing capacity; PERFOBOND; STRENGTH; STIFFNESS; BEHAVIOR; RIBS;
D O I
10.1016/j.istruc.2024.106846
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There are higher requirements for shear connectors as the span length of steel-concrete composite structures increases. T-type perfobond rib (T-type PBL) shear connectors have better mechanical properties than conventional PBL, but the effects of the flange on the overall performance of composite beams have barely been well understood. Therefore, four-point bending tests were first conducted to investigate the failure mode, loaddeflection behavior, and strain distribution of steel-concrete composite beams with the T-type PBL connector under negative bending moments. Subsequently, verified finite element models were established to evaluate the effect of flange width and reinforcement ratio on the flexural performance based on the test results. Finally, a bearing capacity evaluation formula for steel-concrete composite beams in the hogging moment region was proposed considering T-type PBL connectors. Based on the test results, the failure mode of specimens under negative bending moments was bending failure along with cracking of the concrete slab and local buckling of the steel beam flange. The specimens with T-type PBL shear connectors showed better strengthening performance than those with conventional PBL. The bending bearing capacity of composite beams with flange widths of 70 mm, 100 mm, and 130 mm were 6 %, 17 %, and 22 % higher than those with conventional PBL connectors, respectively. The FE parametric study showed that the bearing capacity of the composite beam was improved with the increase of flange width and reinforcement ratio. The flange width and reinforcement ratio of 70 mm and 1 % were recommended, respectively. The evaluation formula was verified by the test and FE results, with an average calculated-to-FE result ratio of 0.99 and a standard deviation of 0.17. This study could enhance the understanding of the behavior of steel-concrete composite beams with T-type PBL connectors in the negative bending moment region and promote the application in long-span composite constructions.
引用
收藏
页数:13
相关论文
共 46 条
  • [21] The Use of Shear Connectors for Enhancing the Performance of Steel-Concrete Composite Beams: Experimental and Numerical Assessment
    Daou, Anas
    Mahayri, Abdul Rahman
    Daou, Yehia
    Baalbaki, Oussama
    Khatib, Milad
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2021, 21 (06) : 1966 - 1976
  • [22] Shear performance of C-shaped perforated angle connectors in steel-concrete composite beams
    Sakhri, Nafissa
    Ihaddoudene, Abd-Nacer Touati
    Saidani, Messaoud
    Da Costa-Neves, Luis Filipe
    STRUCTURES, 2025, 74
  • [23] FEA and bending capacity calculation for mechanical behavior of steel-concrete composite beams under negative bending
    Liu, Yang
    Tong, Lewei
    Sun, Bo
    Chen, Yiyi
    Zhou, Feng
    Tian, Hai
    Sun, Xudong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2014, 35 (10): : 10 - 20
  • [24] Study on the Flexural Behavior of Steel-Concrete Composite Beams Based on the Shear Performance of Headed Stud Connectors
    Zhang, Song
    Jia, Yanmin
    Ding, Yixing
    BUILDINGS, 2022, 12 (07)
  • [25] Experimental study on effect of additional rebar on performance of steel-concrete composite beam in negative moment region
    Li, Tian
    Yin, Jiaen
    Zhao, Tianbing
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (SUPPL.1): : 117 - 122
  • [26] Experimental investigation of the vertical shear performance of steel-concrete composite girders under negative moment
    Zhou, Xuhong
    Men, Pengfei
    Di, Jin
    Qin, Fengjiang
    ENGINEERING STRUCTURES, 2021, 228
  • [27] Ultimate negative bending-moment capacity of outer-plated steel-concrete continuous composite beams
    Chen, Lihua
    Li, Aiqun
    Lou, Yu
    Li, Peibin
    Journal of Southeast University (English Edition), 2009, 25 (01) : 89 - 93
  • [28] Comparative Study on Stability Theory of Steel-concrete Composite Beams in Negative Moment Region Based on ABAQUS
    Wang, Shan
    Ma, Jianxun
    Li, Zongwen
    Ma, Hongmin
    2018 INTERNATIONAL CONFERENCE OF GREEN BUILDINGS AND ENVIRONMENTAL MANAGEMENT (GBEM 2018), 2018, 186
  • [29] Experimental study on full scale steel-concrete composite beams using truss-type shear connectors
    Lima, Jerfson M.
    Bezerra, Luciano M.
    Bonilla, Jorge
    Mirambell, Enrique
    ENGINEERING STRUCTURES, 2024, 303
  • [30] Experimental Study on Fatigue Performance of Negative Bending Moment of Steel-Concrete Continuous Composite Box Girder
    Gao, Pu
    Li, Kuan
    Zheng, Yuanxun
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020