A comparison of machine learning methods for recovering noisy and missing 4D flow MRI data

被引:0
|
作者
Csala, Hunor [1 ,2 ]
Amili, Omid [3 ]
D'Souza, Roshan M. [4 ]
Arzani, Amirhossein [1 ,2 ]
机构
[1] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT USA
[3] Univ Toledo, Dept Mech Ind & Mfg Engn, Toledo, OH USA
[4] Univ Wisconsin Milwaukee, Dept Mech Engn, Milwaukee, WI USA
基金
美国国家科学基金会;
关键词
data imputation; deep learning; denoising; hemodynamics; sparse data-driven modeling; PROPER ORTHOGONAL DECOMPOSITION; MATRIX COMPLETION; CONVEX RELAXATION; ALGORITHMS;
D O I
10.1002/cnm.3858
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Experimental blood flow measurement techniques are invaluable for a better understanding of cardiovascular disease formation, progression, and treatment. One of the emerging methods is time-resolved three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI), which enables noninvasive time-dependent velocity measurements within large vessels. However, several limitations hinder the usability of 4D flow MRI and other experimental methods for quantitative hemodynamics analysis. These mainly include measurement noise, corrupt or missing data, low spatiotemporal resolution, and other artifacts. Traditional filtering is routinely applied for denoising experimental blood flow data without any detailed discussion on why it is preferred over other methods. In this study, filtering is compared to different singular value decomposition (SVD)-based machine learning and autoencoder-type deep learning methods for denoising and filling in missing data (imputation). An artificially corrupted and voxelized computational fluid dynamics (CFD) simulation as well as in vitro 4D flow MRI data are used to test the methods. SVD-based algorithms achieve excellent results for the idealized case but severely struggle when applied to in vitro data. The autoencoders are shown to be versatile and applicable to all investigated cases. For denoising, the in vitro 4D flow MRI data, the denoising autoencoder (DAE), and the Noise2Noise (N2N) autoencoder produced better reconstructions than filtering both qualitatively and quantitatively. Deep learning methods such as N2N can result in noise-free velocity fields even though they did not use clean data during training. This work presents one of the first comprehensive assessments and comparisons of various classical and modern machine-learning methods for enhancing corrupt cardiovascular flow data in diseased arteries for both synthetic and experimental test cases.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Segmentation of 4D Flow MRI: Comparison between 3D Deep Learning and Velocity-Based Level Sets
    Barrera-Naranjo, Armando
    Marin-Castrillon, Diana M. M.
    Decourselle, Thomas
    Lin, Siyu
    Leclerc, Sarah
    Morgant, Marie-Catherine
    Bernard, Chloe
    De Oliveira, Shirley
    Boucher, Arnaud
    Presles, Benoit
    Bouchot, Olivier
    Christophe, Jean-Joseph
    Lalande, Alain
    JOURNAL OF IMAGING, 2023, 9 (06)
  • [42] Fourier Spectral Dynamic Data Assimilation: Interlacing CFD with 4D Flow MRI
    Koltukluoglu, Taha Sabri
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT II, 2019, 11765 : 741 - 749
  • [43] Echocardiographic quantification of retrograde flow in the descending aorta in stroke patients in comparison with 4D flow MRI
    Wehrum, T.
    Guenther, F.
    Kams, M.
    Beryl, P.
    Vach, W.
    Dragonu, I.
    Harloff, A.
    CEREBROVASCULAR DISEASES, 2015, 39 : 20 - 20
  • [44] Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations: Comparison with In Vivo 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (02) : 413 - 424
  • [45] Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations: Comparison with In Vivo 4D Flow MRI
    Jonas Lantz
    Vikas Gupta
    Lilian Henriksson
    Matts Karlsson
    Anders Persson
    Carl-Johan Carlhäll
    Tino Ebbers
    Annals of Biomedical Engineering, 2019, 47 : 413 - 424
  • [46] Identification of the Inflow Zone of Unruptured Cerebral Aneurysms: Comparison of 4D Flow MRI and 3D TOF MRA Data
    Futami, K.
    Sano, H.
    Misaki, K.
    Nakada, M.
    Ueda, F.
    Hamada, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) : 1363 - 1370
  • [47] Comparison of 2D and 4D Flow MRI Measurements for Hemodynamic Evaluation of the Fontan Palliation
    Listo, Elisa
    Martini, Nicola
    Salvadori, Stefano
    Valenti, Elisa
    Stagnaro, Nicola
    Trocchio, Gianluca
    Marrone, Chiara
    Clemente, Alberto
    Raimondi, Francesca
    Festa, Pierluigi
    Ali, Lamia Ait
    CONGENITAL HEART DISEASE, 2023, 18 (06) : 627 - 638
  • [48] 4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications
    Hyodo, Ryota
    Takehara, Yasuo
    Naganawa, Shinji
    RADIOLOGIA MEDICA, 2022, 127 (11): : 1181 - 1198
  • [49] 4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications
    Ryota Hyodo
    Yasuo Takehara
    Shinji Naganawa
    La radiologia medica, 2022, 127 : 1181 - 1198
  • [50] 4D Catalysis Concept Enabled by Multilevel Data Collection and Machine Learning Analysis
    Galushko, Alexey S.
    Ananikov, Valentine P.
    ACS CATALYSIS, 2023, 14 (01) : 161 - 175