Computed tomography numbers obtained for varying iodine contrast concentrations by different-generation dual-energy computed tomography scanners

被引:0
|
作者
Tsukamoto, Tomokatsu [1 ]
Masuda, Takanori [2 ]
Takahata, Takashi [1 ]
Kawamoto, Yoshinori [1 ]
Uenaka, Osamu [1 ]
Mori, Hiroki [1 ]
机构
[1] Onomichi Gen Hosp, Dept Radiol, 1-10-23 Hirahara, Onomichi City, Hiroshima 7228508, Japan
[2] Kawasaki Univ Med Welf, Dept Radiol Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
关键词
CT; QUANTIFICATION;
D O I
10.1093/rpd/ncae174
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We compared the computed tomography (CT) numbers from monochromatic images obtained using the first-generation (Discovery CT750 HD: GE Healthcare, Milwaukee, WI) and second-generation (Revolution CT: GE HealthCare) dual-energy CT (first and second DECT) scanners in phantom and clinical studies. In a polypropylene phantom, eight polypropylene tubes containing iodine at various concentrations (0.5, 1, 2, 5, 10, 12, 20, 30 mg I per ml) were arranged in an outer circle. The iodine densities and CT numbers obtained after imaging with different-generation DECT scanners were analyzed. The CT numbers from images obtained from 61 consecutive patients with aortic disease who underwent CT with different-generation DECT scanners were compared during the arterial and delayed phases. The iodine concentration obtained from second DECT was more accurate than that from the first DECT in the phantom study. A significantly higher contrast enhancement was observed with the second DECT compared with the first DECT during the arterial phase in the clinical study. Contrast enhancement was higher with the second DECT than with the first DECT, and the second DECT was effective in minimizing the use of contrast materials.
引用
收藏
页码:1358 / 1364
页数:7
相关论文
共 50 条
  • [21] Dual-energy computed tomography: what is it useful for?
    Delgado Sanchez-Gracian, C.
    Martinez Rodriguez, C.
    Trinidad Lopez, C.
    RADIOLOGIA, 2013, 55 (04): : 346 - 352
  • [22] Dual-Energy Computed Tomography in Cardiac Imaging
    Boettcher, Benjamin
    Zsarnoczay, Emese
    Varga-Szemes, Akos
    Schoepf, Uwe Joseph
    Meinel, Felix G.
    van Assen, Marly
    De Cecco, Carlo N.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 995 - 1009
  • [23] Dual-energy Computed Tomography Applications in Uroradiology
    Jong Park
    Hersh Chandarana
    Michael Macari
    Alec J. Megibow
    Current Urology Reports, 2012, 13 : 55 - 62
  • [24] Dual-energy Computed Tomography Imaging of the Aorta
    Vlahos, Ioannis
    Godoy, Myrna C. B.
    Naidich, David P.
    JOURNAL OF THORACIC IMAGING, 2010, 25 (04) : 289 - 300
  • [25] Review of dual-energy computed tomography techniques
    Engler, Philip, 1600, (48):
  • [26] Dual-Energy Computed Tomography Technology and Challenges
    Krauss, Bernhard
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 497 - +
  • [27] Dual-Energy Computed Tomography in Body Imaging
    Toia, Giuseppe V.
    Kim, Sooah
    Dighe, Manjiri K.
    Mileto, Achille
    SEMINARS IN ROENTGENOLOGY, 2018, 53 (02) : 132 - 146
  • [28] Pediatric Applications of Dual-Energy Computed Tomography
    Pena-Trujillo, Valeria
    Gallo-Bernal, Sebastian
    Tung, Erik L.
    Gee, Michael S.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 1069 - 1083
  • [29] Dual-Energy Computed Tomography : Technological Considerations
    Chung, Ryan
    Dane, Bari
    Yeh, Benjamin M.
    Morgan, Desiree E.
    Sahani, Dushyant V.
    Kambadakone, Avinash
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 945 - 961
  • [30] Dual-Energy Computed Tomography Applications in Rheumatology
    Park, Eun Hae
    O'Donnell, Thomas
    Fritz, Jan
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2024, 62 (05) : 849 - 863