Computed tomography numbers obtained for varying iodine contrast concentrations by different-generation dual-energy computed tomography scanners

被引:0
|
作者
Tsukamoto, Tomokatsu [1 ]
Masuda, Takanori [2 ]
Takahata, Takashi [1 ]
Kawamoto, Yoshinori [1 ]
Uenaka, Osamu [1 ]
Mori, Hiroki [1 ]
机构
[1] Onomichi Gen Hosp, Dept Radiol, 1-10-23 Hirahara, Onomichi City, Hiroshima 7228508, Japan
[2] Kawasaki Univ Med Welf, Dept Radiol Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
关键词
CT; QUANTIFICATION;
D O I
10.1093/rpd/ncae174
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We compared the computed tomography (CT) numbers from monochromatic images obtained using the first-generation (Discovery CT750 HD: GE Healthcare, Milwaukee, WI) and second-generation (Revolution CT: GE HealthCare) dual-energy CT (first and second DECT) scanners in phantom and clinical studies. In a polypropylene phantom, eight polypropylene tubes containing iodine at various concentrations (0.5, 1, 2, 5, 10, 12, 20, 30 mg I per ml) were arranged in an outer circle. The iodine densities and CT numbers obtained after imaging with different-generation DECT scanners were analyzed. The CT numbers from images obtained from 61 consecutive patients with aortic disease who underwent CT with different-generation DECT scanners were compared during the arterial and delayed phases. The iodine concentration obtained from second DECT was more accurate than that from the first DECT in the phantom study. A significantly higher contrast enhancement was observed with the second DECT compared with the first DECT during the arterial phase in the clinical study. Contrast enhancement was higher with the second DECT than with the first DECT, and the second DECT was effective in minimizing the use of contrast materials.
引用
收藏
页码:1358 / 1364
页数:7
相关论文
共 50 条
  • [1] Optimal Contrast of Computed Tomography Portal Venography Using Dual-Energy Computed Tomography
    Wang, Qi
    Shi, Gaofeng
    Liu, Xiang
    Wu, Runze
    Wang, Shijie
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (02) : 142 - 148
  • [2] Dual-Energy Computed Tomography Dose Reduction, Series Reduction, and Contrast Load Reduction in Dual-Energy Computed Tomography
    Parakh, Anushri
    Macri, Francesco
    Sahani, Dushyant
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 601 - +
  • [3] Accuracy of iodine quantification using dual-energy computed tomography with focus on low concentrations
    Ahnfelt, Anders
    Dahlman, Par
    Segelsjo, Monica
    Magnusson, Mats O.
    Magnusson, Anders
    ACTA RADIOLOGICA, 2022, 63 (05) : 623 - 631
  • [4] Comparison of Iodine Density Measurement Among Dual-Energy Computed Tomography Scanners From 3 Vendors
    Kim, Hyungjin
    Goo, Jin Mo
    Kang, Chang Kyung
    Chae, Kum Ju
    Park, Chang Min
    INVESTIGATIVE RADIOLOGY, 2018, 53 (06) : 321 - 327
  • [5] Evaluation of metal artefact techniques with same contrast scale for different commercially available dual-energy computed tomography scanners
    Kawahara, Daisuke
    Ozawa, Shuichi
    Yokomachi, Kazushi
    Higaki, Toru
    Shiinoki, Takehiro
    Fujioka, Chikako
    Saito, Akito
    Miki, Kentaro
    Kimura, Tomoki
    Murakami, Yuji
    Awai, Kazuo
    Nagata, Yasushi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 539 - 546
  • [6] Evaluation of metal artefact techniques with same contrast scale for different commercially available dual-energy computed tomography scanners
    Daisuke Kawahara
    Shuichi Ozawa
    Kazushi Yokomachi
    Toru Higaki
    Takehiro Shiinoki
    Chikako Fujioka
    Akito Saito
    Kentaro Miki
    Tomoki Kimura
    Yuji Murakami
    Kazuo Awai
    Yasushi Nagata
    Physical and Engineering Sciences in Medicine, 2020, 43 : 539 - 546
  • [7] Introduction to Dual-Energy Computed Tomography
    Elster, Allen D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 823 - 823
  • [8] ACCURACY OF CT NUMBERS OBTAINED BY DIRA AND MONOENERGETIC PLUS ALGORITHMS IN DUAL-ENERGY COMPUTED TOMOGRAPHY
    Magnusson, Maria
    Sandborg, Michael
    Carlsson, Gudrun Alm
    Henriksson, Lilian
    Tedgren, Asa Carlsson
    Malusek, Alexandr
    RADIATION PROTECTION DOSIMETRY, 2021, 195 (3-4) : 212 - 217
  • [9] Correlation of Quantitative Dual-Energy Computed Tomography Iodine Maps and Abdominal Computed Tomography Perfusion Measurements Are Single-Acquisition Dual-Energy Computed Tomography Iodine Maps More Than a Reduced-Dose Surrogate of Conventional Computed Tomography Perfusion?
    Stiller, Wolfram
    Skornitzke, Stephan
    Fritz, Franziska
    Klauss, Miriam
    Hansen, Jens
    Pahn, Gregor
    Grenacher, Lars
    Kauczor, Hans-Ulrich
    INVESTIGATIVE RADIOLOGY, 2015, 50 (10) : 703 - 708
  • [10] Accuracy of spectral curves at different phantom sizes and iodine concentrations using dual-source dual-energy computed tomography
    Kazuhiro Sato
    Ryota Kageyama
    Yuta Sawatani
    Hirokazu Takano
    Shingo Kayano
    Yumi Takane
    Haruo Saito
    Physical and Engineering Sciences in Medicine, 2021, 44 : 103 - 116