Comparison of the diagnostic accuracy of shear wave elastography with transient elastography in adult nonalcoholic fatty liver disease: a systematic review and network meta-analysis of diagnostic test accuracy

被引:0
|
作者
Yamaguchi, Ruri [1 ]
Oda, Tetsuro [2 ]
Nagashima, Kengo [3 ,4 ,5 ]
机构
[1] Tohoku Univ, Grad Sch Med, Dept Invest Pathol, 2-1 Seiryomachi,Aobaku, Sendai 9808575, Japan
[2] Chugai Pharmaceut Co Ltd, Tokyo, Japan
[3] Keio Univ Hosp, Clin & Translat Res Ctr, Biostat Unit, Tokyo 1608582, Japan
[4] Nippon Med Sch, Grad Sch Med, Dept Bioregulat, Tokyo 1138602, Japan
[5] Natl Canc Ctr, Res Inst, Div Canc Therapeut, Tokyo, Japan
关键词
Network meta-analysis; Nonalcoholic fatty liver disease; Shear wave elastography; Transient elastography; STIFFNESS MEASUREMENT; PRACTICE GUIDANCE; MANAGEMENT; FIBROSIS; PERFORMANCE; DESIGN; BIOPSY;
D O I
10.1007/s00261-024-04546-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo compare the diagnostic test accuracy (DTA) of shear wave elastography (SWE) to that of transient elastography (TE) for liver fibrosis grade assessment in nonalcoholic fatty liver disease adults.MethodsMEDLINE, The Cochrane Library, and Web of Science were searched. Inclusion criteria were primary studies examining DTA of TE, point SWE (pSWE), two-dimensional SWE (2D-SWE), or magnetic resonance elastography (MRE) with liver biopsy. Network meta-analysis was conducted using a Bayesian bivariate mixed-effects model.ResultsFor fibrosis grade 2 or higher, 15 studies with 25 observations (16 observations for TE, 1 for MRE, 4 for pSWE and 2D-SWE; 2,066 patients) were included; the pooled sensitivity and specificity were 0.79 (95% credible interval (CrI) 0.70-0.86; 95% prediction interval (PI) 0.36-0.96) and 0.73 (95% CrI 0.62-0.82; 95% PI 0.23-0.96) for TE, 0.68 (95% CrI 0.48-0.83; 95% PI 0.23-0.94) and 0.75 (95% CrI 0.53-0.88; 95% PI 0.24-0.97) for pSWE, 0.85 (95% CrI 0.70-0.93; 95% PI 0.40-0.98) and 0.72 (95% CrI 0.49-0.86; 95% PI 0.20-0.96) for 2D-SWE, respectively. The proportion of studies classified as unclear in QUADAS-2 was high, and the results were heterogeneous.Conclusion2D-SWE could be recommended as TE is for liver fibrosis assessment.The protocol of this systematic review and network meta-analysis has been registered in PROSPERO (CRD42022327249). All included primary papers have already been published and the information and data can be used freely.Conclusion2D-SWE could be recommended as TE is for liver fibrosis assessment.The protocol of this systematic review and network meta-analysis has been registered in PROSPERO (CRD42022327249). All included primary papers have already been published and the information and data can be used freely.
引用
收藏
页码:734 / 746
页数:13
相关论文
共 50 条
  • [31] Diagnostic accuracy of cervical elastography for predicting preterm delivery: Systematic review and meta-analysis
    Sun, Hui
    Lv, Qifeng
    Liu, Tingting
    Zhang, Nan
    Shi, Fengfeng
    SCOTTISH MEDICAL JOURNAL, 2023, 68 (03) : 110 - 120
  • [32] Diagnostic accuracy of cervical elastography in predicting preterm delivery A systematic review and meta-analysis
    Wang, Bo
    Zhang, Yong
    Chen, Shuangshuang
    Xiang, Xiaowei
    Wen, Juan
    Yi, Mei
    He, Baiyun
    Hu, Bing
    MEDICINE, 2019, 98 (29)
  • [33] Diagnostic accuracy of vibration-controlled transient elastography for staging liver fibrosis in autoimmune liver diseases: A systematic review and meta-analysis
    An, Jihyun
    Chon, Young Eun
    Kim, Gunho
    Kim, Mi Na
    Kim, Hee Yeon
    Lee, Han Ah
    Yu, Jung Hwan
    Choi, Miyoung
    Jun, Dae Won
    Kim, Seung Up
    Han, Ji Won
    Jin, Young-Joo
    CLINICAL AND MOLECULAR HEPATOLOGY, 2024, 30 : S134 - +
  • [34] Elastography for the diagnosis of severity of fibrosis in chronic liver disease: A meta-analysis of diagnostic accuracy
    Tsochatzis, E. A.
    Gurusamy, K. S.
    Ntaoula, S.
    Cholongitas, E.
    Davidson, B. R.
    Burroughs, A. K.
    JOURNAL OF HEPATOLOGY, 2011, 54 (04) : 650 - 659
  • [35] Transient Elastography in Alcoholic Liver Disease and Nonalcoholic Fatty Liver Disease: A Systemic Review and Meta-Analysis
    Cai, Changzhou
    Song, Xin
    Chen, Xueyang
    Zhou, Weihua
    Jin, Qi
    Chen, Shenghui
    Ji, Feng
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2021, 2021
  • [36] Diagnostic Performance of Transient Elastography for Liver Fibrosis in Children: A Systematic Review and Meta-Analysis
    Hwang, Jae-Yeon
    Yoon, Hee Mang
    Kim, Jeong Rye
    Lee, Jin Seong
    Jung, Ah Young
    Kim, Kyung Mo
    Cho, Young Ah
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (05) : W257 - W266
  • [37] Comparing the accuracy between shear wave elastography and strain elastography in the diagnosis of breast tumors Systematic review and meta-analysis
    Wu, Huayu
    Zhang, Shengnan
    Wang, Cong
    Yan, Yumei
    MEDICINE, 2022, 101 (18) : E29139
  • [38] Comparison of strain elastography and shear wave elastography in diagnosis of fibrosis in nonalcoholic fatty liver disease
    Ogino, Yu
    Wakui, Noritaka
    Nagai, Hidenari
    Matsuda, Takahisa
    JOURNAL OF MEDICAL ULTRASONICS, 2023, 50 (02) : 187 - 195
  • [39] Comparison of strain elastography and shear wave elastography in diagnosis of fibrosis in nonalcoholic fatty liver disease
    Yu Ogino
    Noritaka Wakui
    Hidenari Nagai
    Takahisa Matsuda
    Journal of Medical Ultrasonics, 2023, 50 : 187 - 195
  • [40] Alcoholic/Nonalcoholic Fatty Liver Disease Detection with Transient Elastography: A Detailed Review and Meta-analysis
    Fang, Yinyou
    Li, Xiaofei
    Zong, Fang
    Jiang, Tianan
    CURRENT MEDICAL IMAGING, 2024, 20