Influence of different head and neck positions on performance characteristics of second generation supraglottic airway devices

被引:0
|
作者
Neha [1 ]
Talwar, Vandana [1 ]
Guria, Sushil [1 ]
Panwar, Mamta [1 ]
Aggarwal, Shipra [1 ]
机构
[1] Vardhman Mahavir Med Coll & Safdarjung Hosp, Delhi, India
关键词
Airway; Anaesthesia; Head and neck; Laryngeal mask; Position; LARYNGEAL MASK AIRWAY; I-GEL; INSERTION; PRESSURE; PROSEAL; CUFF;
D O I
10.1016/j.tacc.2024.101345
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Various head and neck positions alter the performance of supraglottic airway devices (SAD). We compared the influence of flexion, extension, neutral and rotation of the neck on performance characteristics of second generation airway devices namely Proseal (PLMA), i-gel and Auragain laryngeal mask. Methods: This study was conducted in 90 ASA physical status I and II patients 18-65 years of age. Patients were randomised into three groups with 30 patients in each: PLMA, i-gel and Auragain. The primary objective was to compare oropharyngeal leak pressure (OPLP) among PLMA, i-gel and Auragain in neutral, flexion, extension and lateral rotation of the neck. The secondary objective was to compare Peak inspiratory pressure (PIP), ventilation score, expired tidal volume, fiberoptic grading of laryngeal view, end tidal carbon dioxide and OPLP-PIP difference. Results: PLMA, i-gel and Auragain have the highest OPLP in flexion (34.4 +/- 2.5, 31.6 +/- 2.3, 32.8 +/- 1.7) followed by neutral, left lateral rotation and lowest in extension (26.7 +/- 1.6, 25.4 +/- 3.19, 29.6 +/- 1.0) respectively. PLMA and Auragain have significantly higher OPLP when compared to i-gel in all positions p < 0.05. In extension, OPLP with Auragain (29.6 + 1.0) was significantly higher than PLMA (26.7 + 1.6) and i-gel (25.4 + 3.1), p < 0.001. PIP was significantly higher in flexion position for all the three devices. No significant difference in fibre optic grading and ventilation score was seen for three devices in various neck positions. Conclusions: PLMA and Auragain have better sealing pressure than i-gel in all the positions. Flexion position during surgery is best for maintaining OPLP. Auragain should be preferred over PLMA and i-gel in surgeries involving extension of neck.
引用
收藏
页数:5
相关论文
共 50 条
  • [11] Time to abandon the 'vintage' laryngeal mask airway and adopt second-generation supraglottic airway devices as first choice
    Cook, T. M.
    Kelly, F. E.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (04) : 497 - 499
  • [12] Clinical performance of five pediatric supraglottic airway devices
    Nabecker, S.
    Theiler, L.
    Riggenbach, C.
    Kleine-Brueggeney, M.
    Greif, R.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 282 - +
  • [13] Abandoning first generation supraglottic airway devices in paediatric anaesthesia
    Montague, J. P.
    Halloran, C. J.
    ANAESTHESIA, 2017, 72 (01) : 125 - 126
  • [14] Influence of Different Head and Neck Positions on Oropharyngeal Leak Pressure with the LMA Protector Airway: A Cross-over Study
    Deepika
    Prafulla, Ravipati
    Taxak, Susheela
    Govil, Vasudha
    Lallar, Anushmita
    James, Elizabeth
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (09) : UC1 - UC5
  • [15] Second-generation supraglottic airway in laparoscopic donor nephrectomy
    Lee, Ja Eun
    Kim, Ha Yeon
    Lee, Kyo Won
    Kim, Gaab Soo
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [16] Influence of Neck Positions on Airway Protetive Mechanisms
    Amaris, Manuel A.
    Dua, Kulwinder S.
    Naini, Sohrab Rahimi
    Surapaneni, Naveen
    Shaker, Reza
    GASTROENTEROLOGY, 2010, 138 (05) : S464 - S464
  • [17] Second-generation supraglottic airway in laparoscopic donor nephrectomy
    Ja Eun Lee
    Ha Yeon Kim
    Kyo Won Lee
    Gaab Soo Kim
    Scientific Reports, 13
  • [18] Evaluation of I-gel airway in different head and neck positions in anesthetized paralyzed children
    Jain, Divya
    Ghai, Babita
    Bala, Indu
    Gandhi, Komal
    Banerjee, Gargi
    PEDIATRIC ANESTHESIA, 2015, 25 (12) : 1248 - 1253
  • [19] Comparative study of three different supraglottic airway devices in simulated difficult airway situations
    Thierbach, A.
    Piepho, T.
    Goebler, S.
    Ruetzler, K.
    Frass, M.
    Kaye, A. D.
    Robak, O.
    MINERVA ANESTESIOLOGICA, 2015, 81 (12) : 1311 - 1317
  • [20] Performance and skill retention of five supraglottic airway devices for the pediatric difficult airway in a manikin
    Kulnig, Johannes
    Fuereder, Lisa
    Harrison, Nicole
    Frass, Michael
    Robak, Oliver
    EUROPEAN JOURNAL OF PEDIATRICS, 2018, 177 (06) : 871 - 878