Phase classification and transient effects of the start-up process of multi-functional pump station in pump mode

被引:2
|
作者
Zhang, Xiaowen [1 ,2 ,3 ]
Pavesi, Giorgio [2 ]
Xu, Zhe [2 ]
Song, Xijie [1 ]
Tang, Fangping [1 ,2 ]
机构
[1] Yangzhou Univ, Coll Hydraul Sci & Engn, Yangzhou 225009, Peoples R China
[2] Univ Padua, Dept Ind Engn, Via Venezia 1, I-35131 Padua, Italy
[3] Hydrodynam Engn Lab Jiangsu Prov, Yangzhou 225009, Peoples R China
基金
中国国家自然科学基金;
关键词
Multi-functional pump station; Pump mode; Start-up process; Steady-state full characteristic experiment; Transient effect; Phase classification; VORTEX IDENTIFICATION; NUMERICAL-SIMULATION; DYNAMICS; FLOW;
D O I
10.1016/j.est.2024.113517
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the context of achieving the goal of carbon neutrality, multi-functional pump stations (MFPS) have been greatly developed as a new energy system in recent years. The MFPS can operate in forward direction in pump mode to pump water and in turbine mode in reverse direction to generate electricity. At present, the instability of the MFPS during start-up process (SUP) in pump mode has become the key to restricting the operating life and further development of MFPS. In this paper, based on the motion characteristics of the pump and the cut-off facility (COF), the SUP of the MFPS in pump mode is clearly classified. In order to reveal the transient effect during the SUP, the steady-state full characteristic experiment (SFCE) of the pump was carried out. The occurrence phase of the transient effect during the SUP is analyzed, and the deviation between the steady-state external characteristics and the transient characteristics is revealed. In this study, the evaluation formula of the start-up completion degree (SUCD) of the MFPS in pump mode is proposed for the first time, and the evaluation and identification of the start-up progress at different phases are completed. The results show that the water flow in the system is in a reverse flow state in the Phase I. The SUCD of Phase I is 17 %. In the Phase II, The high-speed jet flow in the pump flows to the inlet of the guide vane (GV), which gradually changes the mainstream direction in the GV. A certain vortex structure can be observed at the exit of the flap gate (FG). The SUCD of Phase II is 61 %. In the Phase I and II, the dimensionless head of transient simulation is much larger than that of SFCE. In the Phase III, the flow state in the impeller will gradually stabilize. The transient effect disappears and the pressure fluctuation intensity decreases. The SUCD of Phase III is 93 %. In the Phase IV, the separation vortex that persists from Phase I-III at the tail of the GV blades disappears. The diversion capacity at the gate increases, and significant annular flow can be observed near the FG.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] The filling process and its effect on the start-up of electric pump in hybrid rocket motor
    Gu, Xiaoming
    Tian, Hui
    Tan, Guang
    Liang, Tong
    Wang, Jiangning
    Meng, Xiangyu
    Cai, Guobiao
    ACTA ASTRONAUTICA, 2023, 211 : 216 - 228
  • [22] Pressure Fluctuation Characteristics Analysis of Centrifugal Pump as Turbine in Its Start-Up Process
    Chai, Baodui
    Yang, Junhu
    Wang, Xiaohui
    Jiang, Bingxiao
    ACTUATORS, 2022, 11 (05)
  • [23] 3D Start-up Transition Process of Full Flow System for Shaft-extention Tubular Pump Station
    Xu H.
    Gong Y.
    Cao C.
    Chen H.
    Kan K.
    Feng J.
    Kan, Kan (kankan@hhu.edu.cn), 1600, Chinese Society of Agricultural Machinery (52): : 143 - 151
  • [24] Transient characteristics of pump-jet propelled submarine under different start-up conditions
    Guo, Rang
    Wang, Yuan
    Wang, Xiaoyu
    Li, Reunion
    Li, Jingsheng
    Zhendong yu Chongji/Journal of Vibration and Shock, 2024, 43 (15): : 56 - 62
  • [25] Numerical simulation and experimental study of transient characteristics in an axial flow pump during start-up
    Fu, Shifeng
    Zheng, Yuan
    Kan, Kan
    Chen, Huixiang
    Han, Xingxing
    Liang, Xiaoling
    Liu, Huiwen
    Tian, Xiaoqing
    RENEWABLE ENERGY, 2020, 146 (1879-1887) : 1879 - 1887
  • [26] FLOW TRANSIENT IN PRIMARY COOLANT SYSTEM DURING REACTOR COOLANT PUMP START-UP PERIOD
    Gao, Hong
    Gao, Feng
    Zhao, Xianchao
    Chen, Jie
    Cao, Xuewu
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2013, VOL 1C: SYMPOSIA, 2014,
  • [27] Optimization of the Start-up Time of a Variable Speed Pump-Turbine Unit in Pumping Mode
    Pannatier, Y.
    Kawkabani, B.
    Nicolet, C.
    Schwery, A.
    Simond, J. -J.
    2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2012, : 2126 - 2132
  • [28] Transient simulation of a pump-turbine with misaligned guide vanes during turbine model start-up
    Ye-Xiang Xiao
    Ruo-Fu Xiao
    Acta Mechanica Sinica, 2014, 30 (05) : 646 - 655
  • [29] Transient simulation of a pump-turbine with misaligned guide vanes during turbine model start-up
    Xiao, Ye-Xiang
    Xiao, Ruo-Fu
    ACTA MECHANICA SINICA, 2014, 30 (05) : 646 - 655
  • [30] DYNAMIC CHARACTERISTICS OF A LARGE GAP MAGNETIC DRIVING BLOOD PUMP DURING START-UP PROCESS
    Tan Jianping
    Liu Yunlong
    Xu Yan
    Liu Zhijian
    Zhu Zhongyan
    Jiang Tingting
    MAGNETOHYDRODYNAMICS, 2011, 47 (03): : 283 - 294