Evaluation of biventricular function by cadmium-zinc-telluride SPECT gated tomographic radionuclide angiography: Comparison to conventional SPECT

被引:0
|
作者
Chen, Yue [1 ]
Pang, Zekun [1 ]
Wang, Jiao [1 ]
Yang, Xuewen [1 ]
Li, Jianming [1 ]
机构
[1] TEDA Int Cardiovasc Hosp, Dept Nucl Med, Tianjin, Peoples R China
关键词
biventricular function; cadmium-zinc-telluride; CZT; equilibrium radionuclide ventriculography; ERNV; repeatability; single-photon emission tomography; SPECT; BLOOD-POOL SPECT; RIGHT-VENTRICULAR VOLUMES; EJECTION FRACTION; MYOCARDIAL-PERFUSION; VALUES; CAMERA;
D O I
10.1097/MD.0000000000039821
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared and analyzed the consistency and repeatability of left and right ventricular ((LV/RV) functions obtained by gated-equilibrium radionuclide ventriculography (ERNV) with cadmium-zinc-telluride single-photon emission computed tomography (CZT-SPECT) and conventional SPECT (C-SPECT) with sodium iodide crystal detectors. Seventy-seven patients were included in the retrospective study. Both C-SPECT and CZT-SPECT imaging were performed on the same day. Correlations and differences in LV/RV ejection fraction (LVEF and RVEF), peak ejection rate (PER), and peak filling rate (PFR) were compared between the 2 models. Cardiac magnetic resonance (CMR) was partially used as the gold standard, and ultrasound results were included for comparative analysis. Interobserver reproducibility of each parameter obtained by the 2 cameras was compared. Between the 2 cameras, there were no significant difference in LVEF, LVPER, LVPFR, and RVPER (P > .05) and there were in RVEF and RVPFR (P < .05 or .001). The correlations (R value) were 0.831 (LVEF, excellent), 0.619 (RVEF, good), 0.672 (LVPER, good), 0.700 (LVPFR, good), 0.463 (RVPER, normal), and 0.253 (RVPFR, poor). There were no significant difference between CMR and CZT-SPECT in LVEF (P > .05) while there were between CMR and both C-SPECT and ultrasound (P < .05). The correlations were all good (R = 0.660, 0.658, and 0.695). There were no significant difference between CMR and both C-SPECT and CZT-SPET in RVEF (P > .05) and the correlations were good (R = 0.771 and 0.745). For repeatability, the intraclass correlation coefficient of RVPFR by C-SPECT was good (intraclass correlation coefficient = 0.698) and excellent for the rest of the groups (0.823-0.989). The repeatability of LVEF and RVEF was better for CZT-SPECT than for C-SPECT. The repeatability of PER was better for both cameras than PFR. CZT-SPECT tomographic ERNV correlated well with C-SPECT planar ERNV in evaluation of biventricular systolic function and LV diastolic function. Compared with the "gold standard" CMR, both models had good correlation in measuring LV/RVEF. CZT-SPECT had better inter-group reproducibility than C-SPECT. The accuracy of RV diastolic function need further study. CZT-SPECT tomographic ERNV will play an important and unique role in the clinical application of accurate evaluation of biventricular function in the future.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera
    Haarmark, Christian
    Haase, Christine
    Jensen, Maria Maj
    Zerahn, Bo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (01) : 87 - 97
  • [32] Optimal thallium-201 dose in cadmium-zinc-telluride SPECT myocardial perfusion imaging
    Masaru Ishihara
    Yasuyo Taniguchi
    Masahisa Onoguchi
    Takayuki Shibutani
    Journal of Nuclear Cardiology, 2018, 25 : 947 - 954
  • [33] Optimal thallium-201 dose in cadmium-zinc-telluride SPECT myocardial perfusion imaging
    Ishihara, Masaru
    Taniguchi, Yasuyo
    Onoguchi, Masahisa
    Shibutani, Takayuki
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (03) : 947 - 954
  • [34] Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera
    Jorge Daniel Oldan
    Linda K. Shaw
    Paul Hofmann
    Matthew Phelan
    Jeffrey Nelson
    Robert Pagnanelli
    Salvador Borges-Neto
    Journal of Nuclear Cardiology, 2016, 23 : 1280 - 1287
  • [35] Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols
    Verger, Antoine
    Djaballah, Wassila
    Fourquet, Nicolas
    Rouzet, Francois
    Koehl, Gregoire
    Imbert, Laetitia
    Poussier, Sylvain
    Fay, Renaud
    Roch, Veronique
    Le Guludec, Dominique
    Karcher, Gilles
    Marie, Pierre-Yves
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (03) : 331 - 340
  • [36] Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols
    Antoine Verger
    Wassila Djaballah
    Nicolas Fourquet
    François Rouzet
    Grégoire Koehl
    Laetitia Imbert
    Sylvain Poussier
    Renaud Fay
    Véronique Roch
    Dominique Le Guludec
    Gilles Karcher
    Pierre-Yves Marie
    European Journal of Nuclear Medicine and Molecular Imaging, 2013, 40 : 331 - 340
  • [37] Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera
    Oldan, Jorge Daniel
    Shaw, Linda K.
    Hofmann, Paul
    Phelan, Matthew
    Nelson, Jeffrey
    Pagnanelli, Robert
    Borges-Neto, Salvador
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (06) : 1280 - 1287
  • [38] Quantitative analysis of simultaneous dual-isotope SPECT imaging using a cardiac cadmium-zinc-telluride (CZT) camera: Comparison with conventional Anger camera
    Niimi, T.
    Sugimoto, M.
    Nanasato, M.
    Maeda, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S556 - S556
  • [39] Four-Minute Bone SPECT Using Large-Field Cadmium-Zinc-Telluride Camera
    Gregoire, Bastien
    Pina-Jomir, Geraldine
    Bani-Sadr, Alexandre
    Moreau-Triby, Caroline
    Janier, Marc
    Scheiber, Christian
    CLINICAL NUCLEAR MEDICINE, 2018, 43 (06) : 389 - 395
  • [40] ABSOLUTE CORONARY BLOOD FLOW AND CORONARY FLOW RESERVE ASSESSED BY GATED SPECT WITH CADMIUM-ZINC-TELLURIDE DETECTORS: A DIRECT COMPARISON WITH 13N-AMMONIA PET
    Pazhenkottil, Aju P.
    Nkoulou, Rene
    Kuest, Silke
    Ghadri, Jelena
    Fiechter, Michael
    Fuchs, Tobias
    Herzog, Bernhard
    Buechel, Ronny
    Gaemperli, Oliver
    Kaufmann, Philipp
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1005 - E1005