Numerical investigation on the operation strategy of a chemisorption heat pump system

被引:0
|
作者
Kim, Hak Soo [1 ]
Kim, Dong Ho [1 ]
Kim, Young [1 ]
机构
[1] Korea Inst Machinery & Mat, Heat Pump Res Ctr, 156 Gajeongbuk Ro, Daejeon 34103, South Korea
关键词
Chemisorption; heat pump; performance analysis; operation strategy; dynamic modeling; COMPOSITE SORBENT; RESORPTION SYSTEM; WORKING PAIRS; AMMONIA; POWER; REFRIGERATION; RECOVERY; DRIVEN;
D O I
10.1080/15435075.2024.2381683
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an analysis of the operating characteristics of a chemisorption heat pump. 1-D transient model of a chemisorption heat pump was developed, for which an analysis of four alternating modes of operation was performed. The performance was analyzed with respect to the operating time of the adsorption and desorption operation modes during alternating operations, and the results showed that the cooling capacity has an optimum point depending on the operating times. It was also confirmed that the coefficient of performance increases as the operating time increases. The system performance was also analyzed according to the flow rates of the secondary fluids supplied to the main components. As the flow rates of the secondary fluids supplied to the main components increased, the cooling capacity improved, and the coefficient of performance was found to be compounded by the secondary flow conditions and the operating times of the adsorption and desorption operation modes. Based on the results, it was found that the cooling capacity, coefficient of performance, and specific cooling power of the chemisorption heat pump can be operated in a large range from 876.7 to 3070.0 W, 0.13 to 0.32, and 39.3 to 137.7 W/kg, respectively, depending on the operating conditions.
引用
收藏
页码:3445 / 3457
页数:13
相关论文
共 50 条
  • [41] Analysis on operation characteristics of wind source heat pump system
    Zhang, Yongzhi
    Gu, Jie
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 818 - 821
  • [42] The study on optimal operation of compound heat-pump system
    Shin, Kwan-Woo
    Kim, Ilhyun
    Kim, Yong-Tae
    ICMIT 2007: MECHATRONICS, MEMS, AND SMART MATERIALS, PTS 1 AND 2, 2008, 6794 : U130 - U139
  • [43] DOMESTIC HEAT PUMP OPERATION
    不详
    REFRIGERATION AND AIR CONDITIONING, 1975, 78 (930): : 36 - 36
  • [44] Investigation of a Hybrid Photovoltaic Thermal Heat Pump System
    Chen, Hongbing
    Wei, Ping
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 78 - +
  • [45] Numerical Investigation of the Effect of Using CO2 as the Refrigerant in a Heat Pump Tumble Dryer System
    Erdem, Serkan
    Heperkan, Hasan
    DRYING TECHNOLOGY, 2014, 32 (16) : 1923 - 1930
  • [46] NUMERICAL INVESTIGATION OF THE TRANSCRITICAL CO2 HEAT PUMP SYSTEM EMPLOYING DIFFERENT EXPANSION DEVICES
    Al-Tameemi, Mohammed Ridha Jawad
    Yu, Zhibin
    Younger, Paul
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 66 - 73
  • [47] Field test of a ground-source heat pump system and numerical investigation on advanced control strategies
    Li, Yiming
    Qian, Suxin
    APPLIED THERMAL ENGINEERING, 2024, 246
  • [48] Numerical investigation of a district scale groundwater heat pump system: A case study from Colchester, UK
    Sezer, Taha
    Sani, Abubakar Kawuwa
    Singh, Rao Martand
    Cui, Liang
    Woods, Michael
    Boon, David P.
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [49] Numerical investigation of a simple solar still coupled to a compression heat pump
    Ben Halima, Hanen
    Frikha, Nader
    Ben Slama, Romdhane
    DESALINATION, 2014, 337 : 60 - 66
  • [50] DESIGN STRATEGY FOR HEAT-PUMP ASSISTED DISTILLATION SYSTEM