A study on the enhancement of energy efficiency and indoor environment through the integration of solar photovoltaic modules in daylighting louver systems
被引:0
|
作者:
Jun, Yong-Joon
论文数: 0引用数: 0
h-index: 0
机构:
Dong Eui Univ, Sustainable Community Res Lab, Busan 47340, South KoreaDong Eui Univ, Sustainable Community Res Lab, Busan 47340, South Korea
Jun, Yong-Joon
[1
]
Han, Tae-Gon
论文数: 0引用数: 0
h-index: 0
机构:
Sunportal, Busan 46976, South KoreaDong Eui Univ, Sustainable Community Res Lab, Busan 47340, South Korea
Han, Tae-Gon
[2
]
论文数: 引用数:
h-index:
机构:
Song, Young-Hak
[3
]
论文数: 引用数:
h-index:
机构:
Park, Kyung-Soon
[4
]
机构:
[1] Dong Eui Univ, Sustainable Community Res Lab, Busan 47340, South Korea
[2] Sunportal, Busan 46976, South Korea
[3] Gyeongsang Natl Univ, ERI, Dept Architectural Engn, Jinju 52828, South Korea
[4] Dong Eui Univ, Dept Art & Design, Busan 47340, South Korea
Solar energy;
Louver;
Photovoltaic;
Solar PV Hybrid;
Shadings;
ECONOMIC-GROWTH;
SHADING DEVICES;
VISUAL COMFORT;
PERFORMANCE;
CONSUMPTION;
DEMAND;
D O I:
10.1016/j.solener.2024.112931
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
The global energy demand is predicted to increase significantly, with a strong link between energy consumption and CO2 emissions. Lighting energy accounts for a substantial proportion of total energy consumption in buildings, with the potential to be reduced using daylighting louvers. Despite some drawbacks, integrating solar photovoltaic modules with louvers could enhance energy efficiency while addressing the increasing demand for renewable energy systems in new buildings. Therefore, this study explores the potential benefits of integrating solar photovoltaic (PV) modules into a daylighting louver system to simultaneously reduce lighting, cooling, and heating loads and generate solar power. The performance of the proposed louver system was experimentally compared to a conventional building-integrated photovoltaic (BIPV) system installed on a window. The daylighting louver system demonstrated significant improvements in indoor illumination and occupants' experience compared to the BIPV system. Furthermore, the indoor air temperature in the space with the louver system increased by about 5 degrees compared to the BIPV system, indicating its contribution to heating load reduction. The power generation performance of the louver system reached up to 65 % of the BIPV system, with a total cumulative electricity generation of 64 %. The results suggest that the daylighting louver system can be expanded to enhance its efficiency and address the increasing demand for renewable energy system installations in new buildings. Future studies should investigate the potential of 2-axis or 3-axis louvers to further improve the system's efficiency.
机构:
Department of Architecture, National Taipei University of Technology, Taipei,10608, TaiwanDepartment of Architecture, National Taipei University of Technology, Taipei,10608, Taiwan
Chou, Ding-Chin
Chou, Tse-Ya
论文数: 0引用数: 0
h-index: 0
机构:
College of Design, National Taipei University of Technology, Taipei,10608, TaiwanDepartment of Architecture, National Taipei University of Technology, Taipei,10608, Taiwan
Chou, Tse-Ya
Li, Cheng-Wei
论文数: 0引用数: 0
h-index: 0
机构:
Graduate Institute of Architecture and Urban Design, National Taipei University of Technology, Taipei,10608, TaiwanDepartment of Architecture, National Taipei University of Technology, Taipei,10608, Taiwan
机构:
Fed Inst Educ Sci & Technol Rio Grande Sul IFRS, Nelsi Ribas Fritsch, 1111 Neighborhood Esperanca, BR-98200000 Ibiruba, RS, BrazilFed Inst Educ Sci & Technol Rio Grande Sul IFRS, Nelsi Ribas Fritsch, 1111 Neighborhood Esperanca, BR-98200000 Ibiruba, RS, Brazil
Beltrame, Fernando
Sartori, Hamiltom C.
论文数: 0引用数: 0
h-index: 0
机构:
Santa Maria GEPOC, Power Elect & Control Res Grp, Ave Roraima 1000,Bldg 10, BR-97105900 Santa Maria, RS, BrazilFed Inst Educ Sci & Technol Rio Grande Sul IFRS, Nelsi Ribas Fritsch, 1111 Neighborhood Esperanca, BR-98200000 Ibiruba, RS, Brazil
Sartori, Hamiltom C.
Pinheiro, Jose Renes
论文数: 0引用数: 0
h-index: 0
机构:
Santa Maria GEPOC, Power Elect & Control Res Grp, Ave Roraima 1000,Bldg 10, BR-97105900 Santa Maria, RS, BrazilFed Inst Educ Sci & Technol Rio Grande Sul IFRS, Nelsi Ribas Fritsch, 1111 Neighborhood Esperanca, BR-98200000 Ibiruba, RS, Brazil