Novel self-expandable stent-based endobiliary radiofrequency ablation for unresectable malignant biliary obstruction

被引:0
|
作者
Park, Yubeen [1 ,2 ]
Won, Dong-Sung [1 ]
An, Jin Su [3 ]
Kim, Song Hee [1 ,2 ]
Ryu, Dae Sung [1 ,2 ]
Zeng, Chu Hui [1 ]
Kang, Jeon Min [1 ]
Kim, Ji Won [1 ,2 ]
Kim, Hyung Sik [4 ]
Park, Jung-Hoon [1 ,5 ]
Lee, Sang Soo [2 ]
机构
[1] Asan Inst Life Sci, Biomed Engn Res Ctr, Seoul, South Korea
[2] Asan Med Ctr, Dept Gastroenterol, Seoul, South Korea
[3] Konkuk Univ, Coll Sci & Technol, Sch ICT Convergence Engn, Dept Biomed Engn, Chungju Si, South Korea
[4] Konkuk Univ, Coll Sci & Technol, Sch ICT Convergence Engn, Dept Mechatron Engn, Chungju Si, South Korea
[5] Univ Ulsan, Coll Med, Dept Convergence Med, Asan Med Ctr, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
基金
新加坡国家研究基金会;
关键词
D O I
10.1016/j.gie.2024.04.003
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Endobiliary radiofrequency ablation (RFA) is an emerging endoscopic palliative adjunctive therapy used for the local treatment of unresectable malignant biliary obstruction (MBO). However, irregular ablation ranges caused by insufficient electrode-to-bile duct contact pose a significant obstacle. We investigated the feasibility of a self-expandable stent (SES)-based electrode with a customized RFA generator in the porcine liver and common bile duct (CBD). Methods: An SES-RFA system with polarity switching was developed to perform endobiliary RFA. The ablation ranges of 20 ablation protocols were evaluated to validate the feasibility of the newly developed RFA system in the porcine liver. Nine of 20 ablation protocols were selected for evaluation in the porcine CBD with cholangiography, endoscopy, and histologic and immunohistochemical analysis. Results: The SES-RFA system with polarity switching was successfully constructed and demonstrated high accuracy and reproducibility. The ablation area was clearly identified between the 2 SESs. The ablation ranges and degree of mucosal damage, including terminal deoxynucleotidyl transferase-mediated dUTP nick and labeling- positive and heat shock protein 70-positive depositions, increased proportionally with ablation protocols in the porcine liver and CBD (all P < .05). Ablation length and depth linearly increased with ablation protocols from 8.74 +/- .25 to 31.25 +/- .67 mm and 1.61 +/- .09 to 11.94 +/- .44 mm, respectively. Conclusions: The SES-RFA system with polarity switching between electrodes provided an even circumferential area of ablation and enhanced ablation depth between the electrodes. This novel endobiliary RFA system is a promising modality for local ablation in patients with unresectable MBO.
引用
收藏
页数:20
相关论文
共 50 条
  • [11] Endobiliary radiofrequency ablation combined with bilateral metal stent placement for malignant hilar biliary obstruction
    Inoue, Tadahisa
    Ibusuki, Mayu
    Kitano, Rena
    Kobayashi, Yuji
    Ohashi, Tomohiko
    Nakade, Yukiomi
    Sumida, Yoshio
    Ito, Kiyoaki
    Yoneda, Masashi
    ENDOSCOPY, 2020, 52 (07) : 595 - 599
  • [12] Retrospective evaluation of slim fully covered self-expandable metallic stent for unresectable malignant hilar biliary obstruction
    Takahashi, Sho
    Fujisawa, Toshio
    Ushio, Mako
    Fukuma, Taito
    Suzuki, Akinori
    Takasaki, Yusuke
    Ito, Koichi
    Tomishima, Ko
    Ishii, Shigeto
    Isayama, Hiroyuki
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2023, 30 (03) : 408 - 415
  • [13] Simultaneous triple stent-by-stent deployment following endobiliary radiofrequency ablation for malignant hilar biliary obstruction
    Inoue, Tadahisa
    Kitano, Rena
    Ibusuki, Mayu
    Kobayashi, Yuji
    Ito, Kiyoaki
    Yoneda, Masashi
    ENDOSCOPY, 2021, 53 (05) : E162 - E163
  • [14] Successful Percutaneous Endobiliary Radiofrequency Ablation for Unresectable Malignant Biliary Obstruction: A Case Report and Review of the Literature
    Mao E.J.
    Watson J.B.
    Soares G.
    Habr F.G.
    Journal of Gastrointestinal Cancer, 2014, 45 (Suppl 1) : 55 - 57
  • [15] Efficacy of reverse type self-expandable metallic stent in malignant biliary obstruction
    Kawaguchi, Yoshiaki Kawaguchi
    Kawanishi, Aya
    Kawashima, Yohei
    Ogawa, Masami
    Mine, Tetsuya
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2016, 31 : 228 - 228
  • [16] Double bare self-expandable metal stent for distal malignant biliary obstruction
    Li, Jia-Su
    Liu, Feng
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (03) : 603 - 603
  • [17] Efficacy of the Za self-expandable metal stent for palliation of malignant biliary obstruction
    Varadarajulu, S
    Tutuian, R
    Gostout, C
    Kozarek, R
    Wilcox, CM
    Cotton, PB
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2004, 38 (01) : 77 - 80
  • [18] Endobiliary radiofrequency ablation for unresectable malignant biliary strictures: Survival benefit perspective
    Xia, Mingxing
    Qin, Wenhao
    Hu, Bing
    DIGESTIVE ENDOSCOPY, 2023, 35 (05) : 584 - 591
  • [19] Early experience with endobiliary radiofrequency ablation (Endo-RFA) in patients with unresectable malignant hilar biliary obstruction
    Saraswat, Vivek
    Bhadauria, Arun Singh
    Pande, Gaurav
    Mohindra, Samir
    Butala, Shreya P.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2019, 34 : 390 - 390
  • [20] Self-expandable metal stents in malignant biliary obstruction
    Jaganmohan, Sathya
    Lee, Jeffrey H.
    EXPERT REVIEW OF GASTROENTEROLOGY & HEPATOLOGY, 2012, 6 (01) : 105 - 114