Novel self-expandable stent-based endobiliary radiofrequency ablation for unresectable malignant biliary obstruction

被引:0
|
作者
Park, Yubeen [1 ,2 ]
Won, Dong-Sung [1 ]
An, Jin Su [3 ]
Kim, Song Hee [1 ,2 ]
Ryu, Dae Sung [1 ,2 ]
Zeng, Chu Hui [1 ]
Kang, Jeon Min [1 ]
Kim, Ji Won [1 ,2 ]
Kim, Hyung Sik [4 ]
Park, Jung-Hoon [1 ,5 ]
Lee, Sang Soo [2 ]
机构
[1] Asan Inst Life Sci, Biomed Engn Res Ctr, Seoul, South Korea
[2] Asan Med Ctr, Dept Gastroenterol, Seoul, South Korea
[3] Konkuk Univ, Coll Sci & Technol, Sch ICT Convergence Engn, Dept Biomed Engn, Chungju Si, South Korea
[4] Konkuk Univ, Coll Sci & Technol, Sch ICT Convergence Engn, Dept Mechatron Engn, Chungju Si, South Korea
[5] Univ Ulsan, Coll Med, Dept Convergence Med, Asan Med Ctr, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
基金
新加坡国家研究基金会;
关键词
D O I
10.1016/j.gie.2024.04.003
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Endobiliary radiofrequency ablation (RFA) is an emerging endoscopic palliative adjunctive therapy used for the local treatment of unresectable malignant biliary obstruction (MBO). However, irregular ablation ranges caused by insufficient electrode-to-bile duct contact pose a significant obstacle. We investigated the feasibility of a self-expandable stent (SES)-based electrode with a customized RFA generator in the porcine liver and common bile duct (CBD). Methods: An SES-RFA system with polarity switching was developed to perform endobiliary RFA. The ablation ranges of 20 ablation protocols were evaluated to validate the feasibility of the newly developed RFA system in the porcine liver. Nine of 20 ablation protocols were selected for evaluation in the porcine CBD with cholangiography, endoscopy, and histologic and immunohistochemical analysis. Results: The SES-RFA system with polarity switching was successfully constructed and demonstrated high accuracy and reproducibility. The ablation area was clearly identified between the 2 SESs. The ablation ranges and degree of mucosal damage, including terminal deoxynucleotidyl transferase-mediated dUTP nick and labeling- positive and heat shock protein 70-positive depositions, increased proportionally with ablation protocols in the porcine liver and CBD (all P < .05). Ablation length and depth linearly increased with ablation protocols from 8.74 +/- .25 to 31.25 +/- .67 mm and 1.61 +/- .09 to 11.94 +/- .44 mm, respectively. Conclusions: The SES-RFA system with polarity switching between electrodes provided an even circumferential area of ablation and enhanced ablation depth between the electrodes. This novel endobiliary RFA system is a promising modality for local ablation in patients with unresectable MBO.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] PERCUTANEOUS ENDOBILIARY RADIOFREQUENCY ABLATION AND SELF-EXPANDABLE METAL STENT PLACEMENT VERSUS STENT PLACEMENT ALONE FOR MALIGNANT BILIARY OBSTRUCTION
    Cui, Wei
    Li, Jiaping
    GUT, 2019, 68 : A129 - A130
  • [2] Endobiliary radiofrequency ablation for malignant biliary obstruction
    Alis, Halil
    Sengoz, Cetin
    Gonenc, Murat
    Kalayci, Mustafa Uygar
    Kocatas, Ali
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2013, 12 (04) : 423 - 427
  • [3] Endobiliary radiofrequency ablation for malignant biliary obstruction
    Halil Alis
    Cetin Sengoz
    Murat Gonenc
    Mustafa Uygar Kalayci
    Ali Kocatas
    Hepatobiliary&PancreaticDiseasesInternational, 2013, 12 (04) : 423 - 427
  • [4] Biliary self-expandable metallic stent for unresectable malignant distal biliary obstruction: Which is better: covered or uncovered?
    Isayama, Hiroyuki
    Nakai, Yousuke
    Kogure, Hirofumi
    Yamamoto, Natsuyo
    Koike, Kazuhiko
    DIGESTIVE ENDOSCOPY, 2013, 25 : 71 - 74
  • [5] Percutaneous endobiliary radiofrequency ablation and stent placement for unresectable malignant biliary obstruction: a propensity score matching retrospective study
    Cui, Wei
    Huang, Jing-Zhi
    Wang, Qi
    Shi, Feng
    Gou, Qing
    Chen, Xiao-Ming
    Zhang, Jing
    Li, Jia-Ping
    Xu, Rongde
    BMC GASTROENTEROLOGY, 2024, 24 (01)
  • [6] A dual-modality approach of endobiliary radiofrequency ablation and self-expandable metal stent placement to control malignant hemobilia
    Linz, Christopher M.
    Modi, Rohan M.
    Krishna, Somashekar G.
    ENDOSCOPY, 2017, 49 : E21 - E22
  • [7] The usefulness of endobiliary radiofrequency ablation before metal stent placement in unresectable malignant hilar obstruction
    Oh, Dongwook
    Chong, Junyong
    Song, Tae Jun
    Park, Do Hyun
    Lee, Sang Soo
    Seo, Dong-Wan
    Lee, Sung Koo
    Kim, Myung-Hwan
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2022, 37 (11) : 2083 - 2090
  • [8] Experience in self-expandable metal stent in palliation of malignant biliary obstruction
    Musngi, Joseph Kelvy
    Khow, Jo-Ann
    Co-Soriano, Julius
    Ong, Evan
    Lim, Chen Pen
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2006, 21 : A440 - A440
  • [9] RISK FACTOR OF RECURRENT BILIARY OBSTRUCTION OF COVERED SELF-EXPANDABLE METALLIC STENT FOR UNRESECTABLE DISTAL MALIGNANT BILIARY STRICTURE
    Tanoue, Kojiro
    Maruyama, Hirotsugu
    Yamamoto, Kei
    Manabe, Taku
    Kakiya, Yuki
    Hayashi, Kappei
    Yamamura, Masafumi
    Ominami, Masaki
    Fukunaga, Shusei
    Nadatani, Yuji
    Otani, Koji
    Tanaka, Fumio
    Taira, Koichi
    Kamata, Noriko
    Nagami, Yasuaki
    Tanigawa, Tetsuya
    Watanabe, Toshio
    Fujiwara, Yasuhiro
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB344 - AB345
  • [10] Hyperkalemia after endobiliary radiofrequency ablation for malignant biliary obstruction
    Inoue, Tadahisa
    Kitano, Rena
    Yoneda, Masashi
    DIGESTIVE ENDOSCOPY, 2021, 33 (05) : 874 - 875