Accuracy of Dental Restorations Fabricated Using Milling vs 3D-Printed Molds: A Pilot Study

被引:1
|
作者
Ahlholm, Pekka [1 ,2 ]
Sipila, Kirsi [3 ,4 ]
Tarvonen, Pirkko-Liisa [5 ]
Silvast, Tuomo [6 ]
Lappalainen, Reijo [6 ,7 ]
机构
[1] Univ Eastern Finland, Inst Dent, Kuopio, Finland
[2] Hlth Ctr Lahti, Lahti, Finland
[3] Univ Oulu, Res Unit Oral Hlth Sci, Fac Med, Oulu, Finland
[4] Oulu Univ Hosp, Oral & Maxillofacial Dept, Med Res Ctr Oulu, Oulu, Finland
[5] Univ Helsinki, Dept Oral & Maxillofacial Dis, Clin, Fac Med, Helsinki, Finland
[6] Univ Eastern Finland, SIB Labs, Kuopio, Finland
[7] Univ Eastern Finland, Dept Appl Phys, Biomat Technol, Kuopio, Finland
关键词
INTERNAL FIT; POLYMERIZATION SHRINKAGE; CERAMIC CROWNS; COMPOSITE RESTORATIONS; MARGINAL ADAPTATION; PROVISIONAL CROWNS; RESIN; THICKNESS; INLAYS; LONGEVITY;
D O I
10.11607/ijp.8236
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the accuracy of 12 different dental restorations fabricated with milling or 3D-printed molds and robotically controlled casting. Materials and Methods: Twelve dental restorations (11 inlays and onlays and 1 crown) were made per restoration type, one per each of the 12 different teeth models (total of 24 restorations). On each tooth preparation, two restorations were manufactured using different CAD/ CAM techniques: (1) milling and (2) robotically controlled casting and 3D-printed molds. In addition, two-layer restorations were manufactured with 3D-printed molds. The marginal and internal gaps were evaluated at 120 points per restoration based on micro-CT 3D imaging. Internal gaps were evaluated using a replica technique with silicone. Results: Median values (interquartile ranges) for marginal gaps, middle internal gaps, and central internal gaps were significantly lower for 3D-printed mold restorations (44.3 [65.4] mu m, 95.4 [96.2] mu m, and 104.6 [78.1] mu m) compared to milled restorations (58.4 [93] mu m, 145.9 [85.8] mu m, and 138.6 [65.7] mu m). Internal gaps in the 3D-printed mold group were 6% to 51% smaller than in the milled group. Conclusions: The accuracy of restorations fabricated with 3D-printed molds may be preferable compared to milled restorations, except in the case of crown restoration. However, additional studies with a larger number of samples and different types of restorations are needed to confirm the results.
引用
收藏
页码:S79 / S88
页数:10
相关论文
共 50 条
  • [41] Accuracy assessment of 3D-printed tooth replicas
    Sokolowski, Armin Andreas
    Sokolowski, Alwin Alan
    Kammerhofer, Julian
    Madreiter-Sokolowski, Corina Theresia
    Payer, Michael
    Koller, Martin
    Jakse, Norbert
    Wegscheider, Walther Alfred
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 321 - 329
  • [42] The flexural strength of 3D-printed provisional restorations fabricated with different resins: a systematic review and meta-analysis
    Saini, Ravinder S.
    Gurumurthy, Vishwanath
    Quadri, Syed Altafuddin
    Bavabeedu, Shashit Shetty
    Abdelaziz, Khalid M.
    Okshah, Abdulmajeed
    Alshadidi, Abdulkhaliq Ali F.
    Yessayan, Lazar
    Mosaddad, Seyed Ali
    Heboyan, Artak
    BMC ORAL HEALTH, 2024, 24 (01)
  • [43] The flexural strength of 3D-printed provisional restorations fabricated with different resins: a systematic review and meta-analysis
    Ravinder S. Saini
    Vishwanath Gurumurthy
    Syed Altafuddin Quadri
    Shashit Shetty Bavabeedu
    Khalid M. Abdelaziz
    Abdulmajeed Okshah
    Abdulkhaliq Ali F. Alshadidi
    Lazar Yessayan
    Seyed Ali Mosaddad
    Artak Heboyan
    BMC Oral Health, 24
  • [44] Magnetic Arthropod Millirobots Fabricated by 3D-Printed Hydrogels
    Sun, Bonan
    Jia, Rong
    Yang, Hang
    Chen, Xi
    Tan, Kai
    Deng, Qian
    Tang, Jingda
    ADVANCED INTELLIGENT SYSTEMS, 2022, 4 (01)
  • [45] Verifying the Accuracy of 3D-Printed Objects Using an Image Processing System
    Okamoto, Takuya
    Ura, Sharifu
    JOURNAL OF MANUFACTURING AND MATERIALS PROCESSING, 2024, 8 (03):
  • [46] Fit of anterior restorations made of 3D-printed and milled zirconia: An in-vitro study
    Rues, Stefan
    Zehender, Nathalie
    Zenthoefer, Andreas
    Boemicke, Wolfgang
    Herpel, Christopher
    Ilani, Ali
    Erber, Ralf
    Roser, Christoph
    Lux, Christopher J.
    Rammelsberg, Peter
    Schwindling, Franz Sebastian
    JOURNAL OF DENTISTRY, 2023, 130
  • [47] Deviation of dental implants placed using a novel 3D-printed surgical guide: An in vitro study
    Etajuri, Enas Abdalla
    Suliman, Eshamsul
    Mahmood, Wan Adida Azina
    Ibrahim, Norliza
    Buzayan, Muaiyed
    Mohd, Noorhayati Raja
    DENTAL AND MEDICAL PROBLEMS, 2020, 57 (04) : 359 - 367
  • [48] NOVEL 3D-PRINTED CUSTOM ORAL APPLIANCE THERAPY: A PILOT STUDY
    Glick, Aaron
    Abbassi, Elham
    Farach-Carson, Mary
    SLEEP, 2022, 45 : A165 - A165
  • [49] 3D-Printed specimens as a valuable tool in anatomy education: A pilot study
    Garas, Monique
    Vaccarezza, Mauro
    Newland, George
    McVay-Doornbusch, Kylie
    Hasani, Jamila
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2018, 219 : 57 - 64
  • [50] Fabrication and characterization of 3D-printed elastic auricular scaffolds: A pilot study
    Kim, Ha Yeong
    Jung, Soo Yeon
    Lee, Sang Jin
    Lee, Hyun Jung
    Truong, Minh-Dung
    Kim, Han Su
    LARYNGOSCOPE, 2019, 129 (02): : 351 - 357