Development of Fragility Curves for Tall Buildings with Tuned Liquid Dampers for Vibration Control Under Wind Loading

被引:0
|
作者
Nava-Gonzalez, R. [1 ]
Pozos-Estrada, A. [2 ]
Lopez-Ibarra, A. [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Engn, Dept Struct Engn, Univ City, Mexico City 04510, Mexico
[2] Univ Nacl Autonoma Mexico, Inst Engn, Univ City, Mexico City 04510, Mexico
关键词
Fragility curves; Reliability enhancement; Tall buildings; Tuned liquid dampers; Wind loading; OF-THE-ART; MASS DAMPERS; PRELIMINARY DESIGN; RELIABILITY; PERFORMANCE; TLD;
D O I
10.1007/s40999-024-01020-w
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, fragility curves of a tall building subjected to along-wind loads are developed to evaluate the enhancement in reliability when a Tuned Liquid Damper (TLD) system is employed. For the analysis, a mathematical model of a tall building is designed and subjected to along-wind loads simulated with an autoregressive and moving-average (ARMA) model that includes spatial and temporal variations in the turbulent wind component. For comparison purposes, fragility curves of the tall buildings fitted with a Tuned Mass Damper (TMD) system are also developed. To develop the fragility curves, predefined wind-induced acceleration thresholds are employed as damage states. The numerical results indicate that the use of optimal TLD or TMD systems is effective at reducing the wind-induced acceleration for different mean wind speeds. In addition, the auxiliary damping systems are more effective at reducing the probability of exceedance as the percentage of individuals who perceive acceleration increases from 10 to 50%. Finally, the highest reliability enhancement with the use of both damping systems is achieved for mean wind speed values ranging from 41 to 62 m/s for the damage states considered.
引用
收藏
页码:57 / 70
页数:14
相关论文
共 50 条
  • [21] VIBRATION CONTROL BY MULTIPLE TUNED LIQUID DAMPERS (MTLDS)
    FUJINO, Y
    SUN, LM
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (12): : 3482 - 3502
  • [22] Wind response control of tall buildings with a tuned mass damper
    Elias, Said
    Matsagar, Vasant
    JOURNAL OF BUILDING ENGINEERING, 2018, 15 : 51 - 60
  • [23] Multiple tuned liquid sloshing dampers for across-wind response control of benchmark tall building
    Suthar, Sameer J.
    Jangid, Radhey Shyam
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2022, 7 (01)
  • [24] Seismic Control of Tall Buildings Using Distributed Multiple Tuned Mass Dampers
    Rahmani, Hamid Radmard
    Koenke, Carsten
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [25] Fragility reduction of offshore wind turbines using tuned liquid column dampers
    Hemmati, Arash
    Oterkus, Erkan
    Barltrop, Nigel
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 125
  • [26] Multiple tuned liquid sloshing dampers for across-wind response control of benchmark tall building
    Sameer J. Suthar
    Radhey Shyam Jangid
    Innovative Infrastructure Solutions, 2022, 7
  • [27] A Monte Carlo based method for the dynamic "fragility analysis" of tall buildings under turbulent wind loading
    Smith, Marra A.
    Caracoglia, Luca
    ENGINEERING STRUCTURES, 2011, 33 (02) : 410 - 420
  • [28] Development of a hybrid vibration experiment system for determining wind-induced responses of buildings with tuned dampers
    Matsui, Masahiro
    Tamura, Yukio
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2008, 96 (10-11) : 2033 - 2041
  • [29] Control of tall building vibrations by sealed tuned liquid column dampers
    Hochrainer, Markus J.
    Ziegler, Franz
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (06): : 980 - 1002
  • [30] Tuned liquid dampers simulation for earthquake response control of buildings
    T. Novo
    H. Varum
    F. Teixeira-Dias
    H. Rodrigues
    M. Falcao Silva
    A. Campos Costa
    L. Guerreiro
    Bulletin of Earthquake Engineering, 2014, 12 : 1007 - 1024