Cochlear implant induced changes in cortical networks associated with tinnitus severity

被引:0
|
作者
Shoushtarian, Mehrnaz [1 ,2 ]
Esmaelpoor, Jamal [1 ,2 ]
Bravo, Michelle M. G. [1 ]
Fallon, James B. [1 ,2 ,3 ]
机构
[1] Bion Inst, East Melbourne, Vic, Australia
[2] Univ Melbourne, Med Bion Dept, Melbourne, Vic, Australia
[3] Univ Melbourne, Dept Otolaryngol, Melbourne, Vic, Australia
关键词
tinnitus; cochlear implants; network analysis; functional near-infrared spectroscopy; BRAIN NETWORKS; PERCEPTION;
D O I
10.1088/1741-2552/ad731d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. We investigated tinnitus-related cortical networks in cochlear implant users who experience tinnitus and whose perception of tinnitus changes with use of their implant. Tinnitus, the perception of unwanted sounds which are not present externally, can be a debilitating condition. In individuals with cochlear implants, use of the implant is known to modulate tinnitus, often improving symptoms but worsening them in some cases. Little is known about underlying cortical changes with use of the implant, which lead to changes in tinnitus perception. In this study we investigated whether changes in brain networks with the cochlear implant turned on and off, were associated with changes in tinnitus perception, as rated subjectively. Approach. Using functional near-infrared spectroscopy, we recorded cortical activity at rest, from 14 cochlear implant users who experienced tinnitus. Recordings were performed with the cochlear implant turned off and on. For each condition, participants rated the loudness and annoyance of their tinnitus using a visual rating scale. Changes in neural synchrony have been reported in humans and animal models of tinnitus. To assess neural synchrony, functional connectivity networks with the implant turned on and off, were compared using two network features: node strength and diversity coefficient. Main results. Changes in subjective ratings of loudness were significantly correlated with changes in node strength, averaged across occipital channels ( r=-0.65, p=0.01). Changes in both loudness and annoyance were significantly correlated with changes in diversity coefficient averaged across all channels ( r=-0.79,p<0.001 and r=-0.86,p<0.001 ). More distributed connectivity with the implant on, compared to implant off, was associated with a reduction in tinnitus loudness and annoyance. Significance. A better understanding of neural mechanisms underlying tinnitus suppression with cochlear implant use, could lead to their application as a tinnitus treatment and pave the way for effective use of other less invasive stimulation-based treatments.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Tinnitus Comparison of Electric and Acoustic Stimulation in Elderly Patients with a Cochlear Implant
    Keiner, Andrew
    Frontera, Patrizia
    Tyler, Richard
    Cuda, Domenico
    AUDIOLOGY AND NEURO-OTOLOGY, 2012, 17 : 22 - 24
  • [42] Tinnitus Suppression in Cochlear Implant Patients Using a Sound Therapy App
    Tyler, Richard S.
    Owen, Rachael L.
    Bridges, Julie
    Gander, Phillip E.
    Perreau, Ann
    Mancini, Patricia C.
    AMERICAN JOURNAL OF AUDIOLOGY, 2018, 27 (03) : 316 - 323
  • [43] Cortical Processing of Frequency Changes Reflected by the Acoustic Change Complex in Adult Cochlear Implant Users
    Liang, Chun
    Houston, Lisa M.
    Samy, Ravi N.
    Abedelrehim, Lamiaa Mohamed Ibrahim
    Zhang, Fawen
    AUDIOLOGY AND NEURO-OTOLOGY, 2018, 23 (03) : 152 - 164
  • [44] Changes in the Tinnitus Handicap Questionnaire After Cochlear Implantation
    Pan, Tao
    Tyler, Richard S.
    Ji, Haihong
    Coelho, Claudia
    Gehringer, Anne K.
    Gogel, Stephanie A.
    AMERICAN JOURNAL OF AUDIOLOGY, 2009, 18 (02) : 144 - 151
  • [45] Cortical auditory evoked potentials in cochlear implant patients
    Hoth, S
    HNO, 1998, 46 (08) : 739 - 747
  • [46] Cortical responses to cochlear implant stimulation: Channel interactions
    Bierer, JA
    Middlebrooks, JC
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2004, 5 (01): : 32 - 48
  • [47] Cochlear Implant-Evoked Cortical Activation in Children With Cochlear Nerve Deficiency
    He, Shuman
    Grose, John
    Hang, Anna X.
    Buchman, Craig A.
    OTOLOGY & NEUROTOLOGY, 2012, 33 (07) : 1188 - 1196
  • [48] Cortical Responses to Cochlear Implant Stimulation: Channel Interactions
    Julie Arenberg Bierer
    John C. Middlebrooks
    Journal of the Association for Research in Otolaryngology, 2004, 5 : 32 - 48
  • [49] Cortical Auditory Evoked Potentials Recorded Directly Through the Cochlear Implant in Cochlear Implant Recipients: a Feasibility Study
    Attias, Joseph
    HabibAllah, Suhail
    Tarigoppula, Venkata S. Aditya
    Glick, Hannah
    Chen, Chen
    Kanthaiah, Koka
    Litvak, Leonid
    EAR AND HEARING, 2022, 43 (05): : 1426 - 1436
  • [50] The impact of tinnitus on adult cochlear implant recipients: A mixed-method approach
    Assouly, Kelly K. S. J.
    Shabbir, Maryam A.
    van Dijk, Bas J.
    Hoare, Derek
    Akeroyd, Michael L.
    Stokroos, Robert
    Stegeman, Inge
    Smit, Adriana
    PLOS ONE, 2023, 18 (04):