Cochlear implant induced changes in cortical networks associated with tinnitus severity

被引:0
|
作者
Shoushtarian, Mehrnaz [1 ,2 ]
Esmaelpoor, Jamal [1 ,2 ]
Bravo, Michelle M. G. [1 ]
Fallon, James B. [1 ,2 ,3 ]
机构
[1] Bion Inst, East Melbourne, Vic, Australia
[2] Univ Melbourne, Med Bion Dept, Melbourne, Vic, Australia
[3] Univ Melbourne, Dept Otolaryngol, Melbourne, Vic, Australia
关键词
tinnitus; cochlear implants; network analysis; functional near-infrared spectroscopy; BRAIN NETWORKS; PERCEPTION;
D O I
10.1088/1741-2552/ad731d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. We investigated tinnitus-related cortical networks in cochlear implant users who experience tinnitus and whose perception of tinnitus changes with use of their implant. Tinnitus, the perception of unwanted sounds which are not present externally, can be a debilitating condition. In individuals with cochlear implants, use of the implant is known to modulate tinnitus, often improving symptoms but worsening them in some cases. Little is known about underlying cortical changes with use of the implant, which lead to changes in tinnitus perception. In this study we investigated whether changes in brain networks with the cochlear implant turned on and off, were associated with changes in tinnitus perception, as rated subjectively. Approach. Using functional near-infrared spectroscopy, we recorded cortical activity at rest, from 14 cochlear implant users who experienced tinnitus. Recordings were performed with the cochlear implant turned off and on. For each condition, participants rated the loudness and annoyance of their tinnitus using a visual rating scale. Changes in neural synchrony have been reported in humans and animal models of tinnitus. To assess neural synchrony, functional connectivity networks with the implant turned on and off, were compared using two network features: node strength and diversity coefficient. Main results. Changes in subjective ratings of loudness were significantly correlated with changes in node strength, averaged across occipital channels ( r=-0.65, p=0.01). Changes in both loudness and annoyance were significantly correlated with changes in diversity coefficient averaged across all channels ( r=-0.79,p<0.001 and r=-0.86,p<0.001 ). More distributed connectivity with the implant on, compared to implant off, was associated with a reduction in tinnitus loudness and annoyance. Significance. A better understanding of neural mechanisms underlying tinnitus suppression with cochlear implant use, could lead to their application as a tinnitus treatment and pave the way for effective use of other less invasive stimulation-based treatments.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A Quantitative Electroencephalography Study on Cochlear Implant-Induced Cortical Changes in Single-Sided Deafness with Tinnitus
    Song, Jae-Jin
    Kim, Kyungsoo
    Sunwoo, Woongsang
    Mertens, Griet
    Van de Heyning, Paul
    De Ridder, Dirk
    Vanneste, Sven
    Lee, Sang-Youp
    Park, Kyung-Joon
    Choi, Hongsoo
    Choi, Ji-Woong
    FRONTIERS IN HUMAN NEUROSCIENCE, 2017, 11
  • [2] Cochlear implant and tinnitus
    Olze, Heidi
    Vater, Jana
    Groeschel, Moritz
    Szczepek, Agnieszka J.
    HNO, 2023, 71 (11) : 693 - 701
  • [3] Changes in Tinnitus After Middle Ear Implant Surgery: Comparisons With the Cochlear Implant
    Seo, Young Joon
    Kim, Hyun Ji
    Moon, In Seok
    Choi, Jae Young
    EAR AND HEARING, 2015, 36 (06): : 705 - 709
  • [4] The cochlear implant as a tinnitus treatment
    Valles-Varela, Hector
    Royo-Lopez, Juan
    Carmen-Samperiz, Luis
    Sebastian-Cortes, Jose M.
    Alfonso-Collado, Ignacio
    ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2013, 64 (04): : 253 - 257
  • [5] Cochlear implant in tinnitus management
    Bahmad, Fayez
    Carasek, Natalia
    Lamounier, Pauliana
    CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2023, 31 (02): : 155 - 157
  • [6] Analysis of a Cochlear Implant Database: Changes in Tinnitus Prevalence and Distress After Cochlear Implantation
    Assouly, Kelly K. S.
    Smit, Adriana L.
    Eikelboom, Robert H.
    Sucher, Cathy
    Atlas, Marcus
    Stokroos, Robert J.
    Stegeman, Inge
    TRENDS IN HEARING, 2022, 26
  • [7] A Quantitative Electroencephalography Study on Cochlear Implant-Induced Cortical Changes in Single-Sided Deafness with Tinnitus (vol 11, 210, 2017)
    Song, Jae-Jin
    Kim, Kyungsoo
    Sunwoo, Woongsang
    Mertens, Griet
    Van de Heyning, Paul
    De Ridder, Dirk
    Vanneste, Sven
    Lee, Sang-Youp
    Park, Kyung-Joon
    Choi, Hongsoo
    Choi, Ji-Woong
    FRONTIERS IN HUMAN NEUROSCIENCE, 2018, 12
  • [8] Cortical Encoding of Timbre Changes in Cochlear Implant Users
    Zhang, Fawen
    Benson, Chelsea
    Cahn, Steven J.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2013, 24 (01) : 46 - 58
  • [9] Effects of Tinnitus on Cochlear Implant Programming
    Pierzycki, Robert H.
    Corner, Charlotte
    Fielden, Claire A.
    Kitterick, Padraig T.
    TRENDS IN HEARING, 2019, 23
  • [10] Tinnitus suppression in cochlear implant patients
    Ito, J
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1997, 117 (06) : 701 - 703