Risk Factors for Postoperative Refractive Error in New-Generation Intraocular Lens Calculation Formulas

被引:1
|
作者
Nishida, Shohei [1 ]
Inomata, Yasuya [1 ]
Hirata, Akira [2 ]
机构
[1] Inomata Eye Clin, Kumamoto, Kumamoto, Japan
[2] Hayashi Eye Hosp, Fukuoka, Fukuoka, Japan
来源
CLINICAL OPHTHALMOLOGY | 2024年 / 18卷
关键词
cataract; lens thickness; logistic models; refractive surgical procedures; POWER CALCULATION FORMULAS; EYES; ACCURACY;
D O I
10.2147/OPTH.S471393
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We examined differences in the accuracy of three intraocular lens (IOL) calculation formulas: the traditional SandersRetzlaff-Kraff/Theoretical (SRK/T) formula; the Barrett Universal II (BU II) formula, which is a new-generation IOL calculation formula; and the postoperative spherical equivalent prediction using artificial intelligence and linear algorithms developed by Debellemani & egrave;re, Gatinel, and Saad formula (PEARL-DGS [PEARL]) formula, and evaluated factors that cause postoperative refractive error (PE). Patients and Methods: The study included 205 patients (205 eyes) with a mean age of 75.2 +/- 8.7 years who underwent cataract surgery at our institution from December 2018 to October 2023. The PE of the three IOL calculation formulas was calculated and compared. Multivariate logistic regression analysis was performed with a PE higher than +/- 0.50 D as the dependent variable, and age, sex, axial length (AL), mean keratometry (mean K), anterior chamber depth (ACD), lens thickness (LT), and white-to-white (WTW) as independent variables. Results: The mean PE (ME) +/- standard deviation of the SRK/T, BU II, and PEARL formulas was 0.11 +/- 0.52, 0.11 +/- 0.50, and 0.21 +/- 0.50 D, respectively. MEs of the three IOL calculation formulas were significantly different from 0 (p < 0.01). The median absolute error (MedAE) was not significantly different among the three IOL calculation formulas (p = 0.83). The percentage of PE within +/- 0.50 D was not significantly different among the three IOL calculation formulas (p = 0.13). Multivariate logistic regression analysis showed that the significantly associated factors with PE higher than +/- 0.50 D were AL, ACD, and LT for the SRK/T formula, sex and LT for the BU II formula, and LT for the PEARL formula (all p < 0.05). Conclusion: In the BU II and PEARL formulas, AL was excluded as a factor affecting PE, indicating that LT was a risk factor.
引用
收藏
页码:2253 / 2259
页数:7
相关论文
共 50 条
  • [41] Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients
    Lin, Lei
    Fang, Jiayan
    Sun, Weijie
    Gu, Siyi
    Xu, Liming
    Chen, Siping
    Chang, Pingjun
    Zhao, Yun-e
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (04) : 1019 - 1027
  • [42] Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients
    Lei Lin
    Jiayan Fang
    Weijie Sun
    Siyi Gu
    Liming Xu
    Siping Chen
    Pingjun Chang
    Yun-e Zhao
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 1019 - 1027
  • [43] Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation
    Tokuhisa, Teruaki
    Watanabe, Tomoyuki
    Watanabe, Akira
    Nakano, Tadashi
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (04) : 1213 - 1220
  • [44] Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation
    Teruaki Tokuhisa
    Tomoyuki Watanabe
    Akira Watanabe
    Tadashi Nakano
    International Ophthalmology, 2022, 42 : 1213 - 1220
  • [45] Visual outcomes and optical performance with a monofocal intraocular lens and a new-generation single-optic accommodating intraocular lens
    Alio, Jorge L.
    Pinero, David P.
    Plaza-Puche, Ana B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1656 - 1664
  • [46] Comparison of 9 intraocular lens power calculation formulas
    Cooke, David L.
    Cooke, Timothy L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1157 - 1164
  • [47] Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis
    Hongyu Li
    Zi Ye
    Yu Luo
    Zhaohui Li
    International Ophthalmology, 2023, 43 : 619 - 633
  • [48] THEORETICAL FORMULAS FOR INTRAOCULAR-LENS POWER CALCULATION
    AFLALO, G
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1987, 10 (04): : 283 - 293
  • [49] Intraocular Lens Power Calculation Formulas—A Systematic Review
    Wiktor Stopyra
    Achim Langenbucher
    Andrzej Grzybowski
    Ophthalmology and Therapy, 2023, 12 : 2881 - 2902
  • [50] THE MULTICOMPONENT INTRAOCULAR-LENS - A NEW GENERATION OF ADJUSTABLE REFRACTIVE IOLS
    WERBLIN, TP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1452 - 1452