Enhancing the building resilience in a changing climate through a passive cooling roof: A case study in Camas (Seville, Spain)

被引:1
|
作者
Palma, Rafael Monge [1 ]
Medina, Daniel Castro [2 ]
Delgado, MCarmen Guerrero [1 ]
Ramos, Jose Sanchez [1 ]
Montero-Gutierrez, Paz [1 ]
Dominguez, Servando Alvarez [1 ]
机构
[1] Univ Seville, Grp Termotecnia, Escuela Super Ingn, Seville, Spain
[2] Univ Cadiz, Escuela Super Ingn, Grp Termotecnia, Cadiz, Spain
关键词
Resilient buildings; Passive cooling; Double-skin roof; Thermal comfort; Energy poverty; ADAPTIVE THERMAL COMFORT; NIGHT VENTILATION; RESIDENTIAL BUILDINGS; ENERGY PERFORMANCE; SOLAR CHIMNEY; RENOVATION; SIMULATION; STRATEGIES; STANDARDS; DESIGN;
D O I
10.1016/j.enbuild.2024.114680
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Renovating buildings is a crucial mission for the coming decades to combat energy inefficiencies and produce a resilient building stock. The inefficient thermal envelope has significant implications for occupants, especially for families lacking the financial resources to maintain a healthy and comfortable indoor environment. In scenarios where households cannot afford or utilize HVAC systems and high temperatures are more frequent, building retrofits should prioritize reducing heat loss in winter and passively lowering indoor temperatures in the cooling season. This work introduces a new solution to enhance the liveability of a social housing building in southern Spain by integrating a double-skin roof with a conventional retrofit strategy, which incorporates passive cooling techniques - night ventilation and an evaporative cooling system - for effective heat dissipation based on available commercial solutions. An extensive monitoring campaign was conducted over three years to evaluate the thermal comfort of occupants and the risk of overheating in naturally conditioned buildings before and after renovation following two impact assessment methods: real-time data-based and simulation-based. The real-time data-based method compared the indoor conditions of a dwelling with a conventionally retrofitted roof to one with a double-skin roof, indicating that the dynamic roof maintains a ceiling temperature lower than the air temperature throughout the summer while the conventional roof acts as a heating surface. On the other side, the simulation-based method compared the observed indoor conditions with a double-skin roof enabled during 2023 to the initial stage and a double-skin roof disabled scenario, using calibrated building energy models. The natural cooling roof solution almost eliminates the overheating events, leading to a reduction of 94.1% and 76.9% in discomfort degree-hours compared to the initial stage according to the ASHRAE adaptative and Fanger comfort models, respectively. Additionally, the results indicate that conventional retrofits can increase the risk of overheating when a cooling system is not considered. Integrating a cool roof solution requires only an extra implementation cost of 31<euro>/m2 compared to a conventional solution, having an operational cost that represents less than 3% of the minimum monthly income in the social housing district.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Passive downdraught evaporative cooling system integration in existing residential building typologies: a case study
    Chiesa, Giacomo
    Grosso, Mario
    Bogni, Alessio
    Garavaglia, Giacomo
    8TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, SEB-16, 2017, 111 : 609 - 618
  • [32] An Experimental and Numerical Case Study of Passive Building Cooling with Foundation Pile Heat Exchangers in Denmark
    Poulsen, Soren Erbs
    Alberdi-Pagola, Maria
    Cerra, Davide
    Magrini, Anna
    ENERGIES, 2019, 12 (14)
  • [33] Cooling effectiveness of south facade passive stacks in a naturally ventilated office building - Case study
    Riain, CN
    Kolokotroni, M
    Davies, M
    Fisher, J
    White, M
    Littler, J
    INDOOR AND BUILT ENVIRONMENT, 1999, 8 (05) : 309 - 321
  • [34] Enhancing Urban Resilience through Technology and Social Media: Case Study of Urban Jakarta
    Sitinjak, Efraim
    Meidityawati, Bevita
    Ichwan, Ronny
    Onggosandojo, Niken
    Aryani, Parinah
    7TH INTERNATIONAL CONFERENCE ON BUILDING RESILIENCE: USING SCIENTIFIC KNOWLEDGE TO INFORM POLICY AND PRACTICE IN DISASTER RISK REDUCTION, 2018, 212 : 222 - 229
  • [35] Renewable energy solutions for building cooling, heating and power system installed in an institutional building: Case study in southern Spain
    Rosiek, Sabina
    Javier Batlles, Francisco
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 26 : 147 - 168
  • [36] A ROADMAP FOR BUILDING CLIMATE RESILIENCE AT HIGHER EDUCATION INSTITUTIONS: A CASE STUDY OF ARIZONA STATE UNIVERSITY
    Campbell, Hailey
    Crippen, Alise
    Hawkey, Corey
    Dalrymple, Mick
    JOURNAL OF GREEN BUILDING, 2020, 15 (04): : 237 - 256
  • [37] A roadmap for building climate resilience at higher education institutions: A case study of arizona state university
    Campbell H.
    Crippen A.
    Hawkey C.
    Dalrymple M.
    Journal of Green Building, 2020, 15 (04): : 237 - 256
  • [38] Local climate zones and its potential for building urban resilience: a case study of Lahore, Pakistan
    Aslam, Ayman
    Rana, Irfan Ahmad
    Bhatti, Saad Saleem
    INTERNATIONAL JOURNAL OF DISASTER RESILIENCE IN THE BUILT ENVIRONMENT, 2022, 13 (02) : 248 - 265
  • [39] Building resilience to water scarcity in southern Spain: a case study of rice farming in Doana protected wetlands
    Garcia de Jalon, Silvestre
    Iglesias, Ana
    Cunningham, Ruth
    Perez Diaz, Juan I.
    REGIONAL ENVIRONMENTAL CHANGE, 2014, 14 (03) : 1229 - 1242
  • [40] Building disaster resilience through emergency Plan updates: A case study of Ya'an, China
    Zhang, Meilian
    Zheng, Wei
    INTERNATIONAL JOURNAL OF DISASTER RISK REDUCTION, 2024, 100