Virtual Needle Insertion with Enhanced Haptic Feedback for Guidance and Needle-Tissue Interaction Forces

被引:0
|
作者
Selim, Mostafa [1 ]
Dresscher, Douwe [1 ]
Abayazid, Momen [1 ]
机构
[1] Univ Twente, Fac Elect Engn Math & Comp Sci, Robot & Mechatron Res Grp, NL-7500 AE Enschede, Netherlands
关键词
liver cancer; CT liver biopsy; haptic feedback; needle insertion simulation; needle guidance; TELEOPERATION;
D O I
10.3390/s24175560
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interventional radiologists mainly rely on visual feedback via imaging modalities to steer a needle toward a tumor during biopsy and ablation procedures. In the case of CT-guided procedures, there is a risk of exposure to hazardous X-ray-based ionizing radiation. Therefore, CT scans are usually not used continuously, which increases the chances of a misplacement of the needle and the need for reinsertion, leading to more tissue trauma. Interventionalists also encounter haptic feedback via needle-tissue interaction forces while steering a needle. These forces are useful but insufficient to clearly perceive and identify deep-tissue structures such as tumors. The objective of this paper was to investigate the effect of enhanced force feedback for sensing interaction forces and guiding the needle when applied individually and simultaneously during a virtual CT-guided needle insertion task. We also compared the enhanced haptic feedback to enhanced visual feedback. We hypothesized that enhancing the haptic feedback limits the time needed to reach the target accurately and reduces the number of CT scans, as the interventionalist depends more on real-time enhanced haptic feedback. To test the hypothesis, a simulation environment was developed to virtually steer a needle in five degrees of freedom (DoF) to reach a tumor target embedded in a liver model. Twelve participants performed in the experiment with different feedback conditions where we measured their performance in terms of the following: targeting accuracy, trajectory tracking, number of CT scans required, and the time needed to finish the task. The results suggest that the combination of enhanced haptic feedback for guidance and sensing needle-tissue interaction forces significantly reduce the number of scans and the duration required to finish the task by 32.1% and 46.9%, respectively, when compared to nonenhanced haptic feedback. The other feedback modalities significantly reduced the duration to finish the task by around 30% compared to nonenhanced haptic feedback.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Simulation and experimental studies in needle-tissue interactions
    Konh, Bardia
    Honarvar, Mohammad
    Darvish, Kurosh
    Hutapea, Parsaoran
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (04) : 861 - 872
  • [42] Online Needle-Tissue Interaction Model Identification for Force Feedback Enhancement in Robot-Assisted Interventional Procedures
    Ferro, Marco
    Gaz, Claudio
    Anzidei, Michele
    Vendittelli, Marilena
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2021, 3 (04): : 936 - 947
  • [43] Haptic simulation of flexible needle insertion
    He, Xuejian
    Chen, Yonghua
    Tang, Libo
    2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-5, 2007, : 607 - 611
  • [44] Review on Needle Insertion Haptic Simulation
    Benjamin Delbos
    Rémi Chalard
    Richard Moreau
    Minh Tu Pham
    Arnaud Lelevé
    Current Robotics Reports, 2022, 3 (4): : 259 - 270
  • [45] A Virtual Sensor for Needle Deflection Estimation during Soft-Tissue Needle Insertion
    Lehmann, Thomas
    Rossa, Carlos
    Usmani, Nawaid
    Sloboda, Ronald
    Tavakoli, Mandi
    2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2015, : 1217 - 1222
  • [46] Modeling of needle-tissue interaction using ultrasound-based motion estimation
    Dehghan, Ehsan
    Wen, Xu
    Zahiri-Azar, Reza
    Marchal, Maud
    Salcudean, Septimiu E.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 709 - +
  • [47] Augmented Haptic Guidance for Needle Insertion with a 2-DoF Wrist-Worn Haptic Device
    Sarac, Mine
    Loke, Duke
    Evans, Max
    Chong, Olivia
    Saunders, James
    Makled, Basiel
    Okamura, Allison M.
    Hallett, Kim
    2021 IEEE WORLD HAPTICS CONFERENCE (WHC), 2021, : 872 - 872
  • [48] Reality-based needle insertion simulation for haptic feedback in prostate brachytherapy
    Hing, James T.
    Brooks, Ari. D.
    Desai, Jaydev P.
    2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-10, 2006, : 619 - +
  • [49] Laboratory study on needle-tissue interaction: Towards the development of an instrument for automatic venipuncture
    De Boer, T.
    Steinbuch, M.
    Neerken, S.
    Kharin, A.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2007, 7 (03) : 325 - 335
  • [50] A novel material point method (MPM) based needle-tissue interaction model
    Li, Murong
    Lei, Yong
    Gao, Dedong
    Hu, Yingda
    Zhang, Xiong
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (12) : 1393 - 1407