Transfer accuracy of 3D printed versus CAD/CAM milled surgical guides for temporary orthodontic implants: A preclinical micro CT study

被引:3
|
作者
Schwarzler, Alexander [1 ]
Ludwig, Bjoern [2 ]
Chitan, Patrick [1 ]
Lettner, Stefan [3 ,4 ]
Sagl, Benedikt [5 ]
Jonke, Erwin [1 ]
机构
[1] Med Univ Vienna, Univ Clin Dent, Dept Orthodont, Vienna, Austria
[2] Saarland Univ, Dept Orthodont, Saar, Germany
[3] Med Univ Vienna, Univ Clin Dent, Karl Donath Lab Hard Tissue & Biomat Res, Vienna, Austria
[4] Austrian Cluster Tissue Regenerat, Vienna, Austria
[5] Med Univ Vienna, Univ Clin Dent, Ctr Clin Res, Vienna, Austria
关键词
Digital dentistry; Temporary anchorage devices; Guided implantation; CAD/CAM; Dental milling; Medical 3D printing; SKELETAL; INSERTION;
D O I
10.1016/j.jdent.2024.105060
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Temporary anchorage devices (TADs) have become an integral part of comprehensive orthodontic treatments. This study evaluated the transfer accuracy of three-dimensional (3D) printed and computer-aided design/computer-aided manufacturing (CAD/CAM) milled surgical guides for orthodontic TADs using micro- computed tomography (CT) imaging in a preclinical trial. Methods: Overall, 30 surgical guides were used to place TADs into typodonts; 3D printing and CAD/CAM milling were used to produce the guides. The virtual target positions of the TADs were compared to the real positions in terms of spatial and angular deviations using digital superimposition. Micro-CT imaging was used to detect the positions. To evaluate reliability, two investigators collected the measurements twice. Intra-rater and inter-rater correlations were tested. Results: In total, 60 palatal TADs were evaluated. The mean coronal deviations in the print group ranged from 0.15 f 0.20 mm to 0.71 f 0.22 mm, whereas in the mill group, they ranged from 0.09 f 0.15 mm to 0.83 f 0.23 mm. At the apical tip, the overall deviations in the print group ranged from 0.14 f 0.56 mm to 1.27 f 0.66 mm, whereas in the mill group, they ranged from 0.15 f 0.57 mm to 1.09 f 0.44 mm. The mean intra-class and interclass correlation coefficients ranged from 0.904 to 0.987. No statistically significant differences were found between the groups. Conclusions: CAD/CAM milled guides yielded spatial and angular accuracies comparable to those of 3D printed guides with notable deviations in the vertical positioning of TADs. Clinical significance: Digital planning of orthodontic temporary implants combines clinical predictability and the safety of surrounding tissue. Therefore, the transfer accuracy of the guides is crucial. This preclinical study was the first to evaluate CAD/CAM milling for orthodontic guides and found its accuracy comparable to that of the current "gold standard".
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Accuracy and precision of 3D-printed implant surgical guides with different implant systems: An in vitro study
    Yeung, Matthew
    Abdulmajeed, Aous
    Carrico, Caroline K.
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (06): : 821 - 828
  • [32] In-vitro Comparative Evaluation for the Surface Properties and Impact Strength of CAD/CAM Milled, 3D Printed, and Polyamide Denture Base Resins
    Helal, Mohamed A.
    Fadl-Alah, Ahmed
    Baraka, Yasser M.
    Gad, Mohammed M.
    Emam, Abdel-Naser M.
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2022, 12 (01): : 126 - 131
  • [33] Investigation of the effects of spinal surgical implants on radiotherapy dosimetry: A study of 3D printed phantoms
    Goodall, Simon K.
    Rampant, Peter
    Smith, Warwick
    Waterhouse, David
    Rowshanfarzad, Pejman
    Ebert, Martin A.
    MEDICAL PHYSICS, 2021, 48 (08) : 4586 - 4597
  • [34] 3D printed fracture reduction guides planned and printed at the point of care show high accuracy - A cadaveric feasibility study
    Eberlein, Sophie C.
    Hess, Silvan
    Klenke, Frank Michael
    Hecker, Andreas
    SWISS MEDICAL WEEKLY, 2023, 153 : 54S - 54S
  • [35] 3D printed fracture reduction guides planned and printed at the point of care show high accuracy - a porcine feasibility study
    Hecker, Andreas
    Eberlein, Sophie C.
    Klenke, Frank M.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2022, 9 (01)
  • [36] 3D printed fracture reduction guides planned and printed at the point of care show high accuracy – a porcine feasibility study
    Andreas Hecker
    Sophie C. Eberlein
    Frank M. Klenke
    Journal of Experimental Orthopaedics, 9
  • [37] Effect of Storage Conditions and Time on the Dimensional Stability of 3D Printed Surgical Guides: An In Vitro Study
    Ntovas, Panagiotis
    Marchand, Laurent
    Basir, Barmak
    Kudara, Yukio
    Revilla-Leon, Marta
    Att, Wael
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (01) : 92 - 99
  • [38] Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases
    Emam, Abdel-Naser M.
    El-Esawy, Ahmed Ayman
    Alyami, Mohammed Hamad
    Baraka, Yasser
    Gad, Mohammed M.
    Helal, Mohamed Ahmed
    DENTISTRY JOURNAL, 2024, 12 (02)
  • [39] Transfer accuracy of 3D-printed trays for indirect bonding o orthodontic brackets: A clinical study
    Bachour, Petra C.
    Klabunde, Robert
    Grunheid, Thorsten
    ANGLE ORTHODONTIST, 2022, 92 (03) : 372 - 379
  • [40] A comparative study of strength and surface properties of permanent 3D-printed resins with CAD-CAM milled fixed dental prostheses
    Gad, Mohammed M.
    Al Mahfoudh, Hoor A.
    Al Mahfuth, Fatimah A.
    Hashim, Kouthar A.
    Khan, Soban Q.
    Al-Qarni, Faisal D.
    Baba, Nadim Z.
    Al-Harbi, Fahad A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,