Dynamic performance of a supertall building with an active tuned mass damper system during Super Typhoon Saola

被引:2
|
作者
Xu, Kang [1 ]
Li, Qiusheng [1 ,2 ]
Zhou, Kang [3 ]
Han, Xuliang [1 ,2 ]
机构
[1] City Univ Hong Kong, Shenzhen Res Inst, Architecture & Civil Engn Res Ctr, Shenzhen, Peoples R China
[2] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[3] Hefei Univ Technol, Coll Civil Engn, Hefei, Peoples R China
关键词
Dynamic property; Wind effect; Skyscraper; Structural health monitoring; Tropical cyclone; Active control technique; Field measurement; WIND-INDUCED RESPONSES; VIBRATION CONTROL; TALL BUILDINGS; MODEL; ATMD;
D O I
10.1016/j.engstruct.2024.118778
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the dynamic characteristics (natural frequencies and damping ratios) of a 600-m-tall supertall building with an active tuned mass damper (ATMD) system during Super Typhoon Saola. Based on the wind speed, wind direction, and wind-induced acceleration response records by the structural health monitoring (SHM) system installed on the skyscraper, the wind characteristics during the passage of Saola are first investigated, and the relations between the mean wind speeds atop the skyscraper and the root-mean-square (RMS) acceleration responses are established. Then, employing the stochastic subspace identification (SSI) method and an uncertainty quantification method, this paper comprehensively investigates the uncertainty bounds, time-varying features, and amplitude-dependency characteristics of the modal parameters with and without the operation of the ATMD system. Next, on the basis of the identified modal parameters and timefrequency analysis, the performance and effectiveness of the ATMD system in suppressing the wind-induced vibrations of the skyscraper is investigated. Lastly, the structural health condition is evaluated from the perspective of building natural frequency and damping ratio changes before and after the typhoon hit. The goal of this study is to advance the understanding of the wind effects on supertall buildings and provide useful information for the wind-resistant design and vibration control of supertall buildings in tropical cyclone-prone regions.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Dynamic analysis of viscoelastic tuned mass damper system under harmonic excitation
    Dai, Jun
    Xu, Zhao-Dong
    Gai, Pan-Pan
    JOURNAL OF VIBRATION AND CONTROL, 2019, 25 (11) : 1768 - 1779
  • [22] Fuzzy neural network control algorithm for asymmetric building structure with active tuned mass damper
    Yan, Xiao
    Xu, Zhao-Dong
    Shi, Qing-Xuan
    JOURNAL OF VIBRATION AND CONTROL, 2020, 26 (21-22) : 2037 - 2049
  • [23] Influence of soil-structure interaction on performance of a super tall building using a new eddy-current tuned mass damper
    Zhou, Zhiguang
    Wei, Xiaodong
    Lu, Zheng
    Jeremic, Boris
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2018, 27 (14):
  • [24] Dynamic analysis of a tall building with a tuned-mass-damper device subjected to earthquake excitations
    Wang, AP
    Fung, RF
    Huang, SC
    JOURNAL OF SOUND AND VIBRATION, 2001, 244 (01) : 123 - 136
  • [25] High performance active tuned mass damper inerter for structures under the ground acceleration
    Li, Chunxiang
    Cao, Liyuan
    EARTHQUAKES AND STRUCTURES, 2019, 16 (02) : 149 - 163
  • [26] Vibration control of multi-story building structure by hybrid control using tuned liquid damper and active mass damper
    Shin, Ji-Hwan
    Kwak, Moon K.
    Kim, Soo-Min
    Baek, Kwang-Hyun
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (12) : 5005 - 5015
  • [27] Performance-based Seismic Design of a Pendulum Tuned Mass Damper System
    Shu, Zhan
    Li, Shuang
    Sun, Xiaofeng
    He, Minjuan
    JOURNAL OF EARTHQUAKE ENGINEERING, 2019, 23 (02) : 334 - 355
  • [28] Wavelet-neuro-fuzzy control of hybrid building-active tuned mass damper system under seismic excitations
    Mitchell, Ryan
    Kim, Yeesock
    El-Korchi, Tahar
    Cha, Young-Jin
    JOURNAL OF VIBRATION AND CONTROL, 2013, 19 (12) : 1881 - 1894
  • [29] Vibration control of multi-story building structure by hybrid control using tuned liquid damper and active mass damper
    Ji-Hwan Shin
    Moon K. Kwak
    Soo-Min Kim
    Kwang-Hyun Baek
    Journal of Mechanical Science and Technology, 2020, 34 : 5005 - 5015
  • [30] Effectiveness of active tuned mass damper and seismic isolation on vibration control of multi-storey building
    Loh, CH
    Chao, CH
    JOURNAL OF SOUND AND VIBRATION, 1996, 193 (04) : 773 - 792