Janus-structured colorimetric and fluorescent nanocomposites with highly luminescent retention to enhance point-of-care diagnosis

被引:2
|
作者
Shen, Xuan-ang [1 ,2 ]
Chen, Xirui [1 ,2 ]
Zhou, Haoxiang [1 ,2 ]
Chen, Song [3 ]
Wu, Jinyu [1 ,2 ]
Li, Xiangmin [2 ,4 ]
Huang, Xiaolin [1 ,2 ]
Xiong, Yonghua [1 ,2 ,4 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Resources, Nanchang 330047, Peoples R China
[2] Nanchang Univ, Sch Food Sci & Technol, Nanchang 330047, Peoples R China
[3] Guangzhou Dev Dist, AIE Inst, Guangzhou Dev Dist, Guangzhou 510530, Peoples R China
[4] Nanchang Univ, Jiangxi OAI Joint Res Inst, Nanchang 330047, Jiangxi, Peoples R China
关键词
Colorimetric-fluorescent bifunctional; nanocomposite; Janus structure; Aggregation-induced emission luminogen; Lateral flow immunoassay; C -reaction protein; aflatoxin M 1; AGGREGATION-INDUCED EMISSION; AFLATOXIN M1; MILK; IMMUNOASSAY; ASSAY;
D O I
10.1016/j.cej.2024.154825
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Lateral flow immunoassay (LFIA) with dual-readout signals offers significant advantages in point-of-care testing due to its adaptability to various analysis scenarios. However, colorimetric and fluorescent nanocomposites (cfNCs) composed of plasmonic and luminescent components often suffer from low luminescent efficiency because of severe optical interference between the two functional components. Herein, we propose a simple self-assembly strategy for fabricating novel cf-NCs with a Janus structure (J-cf-NCs) using oleylamine ligand-coated gold nanoparticles (OA-AuNPs) and aggregation-induced emission luminogens (AIEgens) as building blocks. For comparison, two other cf-NCs with core-shell (CS-cf-NCs) and co-embedding (CE-cf-NCs) structures were synthesized to explore the effects of spatial intersection of OA-AuNPs and AIEgens on their optical properties. Our results demonstrate that J-cf-NCs exhibit the highest fluorescence retention (75 %), as the face-to-face spatial distribution of OA-AuNPs and AIEgens effectively prevents fluorescence resonance energy transfer and minimizes inner-filter effect-induced fluorescence quenching. When integrated with the LFIA platform, the developed J-cfNC-LFIA demonstrated excellent detection performance for both qualitative and quantitative determination of various target analytes in sandwich and competitive formats. Specifically, the visual limit of detection (vLOD) for C-reactive protein using J-cf-NC-LFIA showed approximately an eight-fold improvement compared to the classical colloidal gold test strip, while the quantitative sensitivity was two orders of magnitude greater than that of colorimetric readout. Furthermore, the vLOD for aflatoxin M1 in milk samples was 0.5 ng center dot mL-1, with a quantitative sensitivity 38-fold higher than that of the colorimetric pattern. Overall, the proposed J-cf-NCs exhibit significant potential for enhancing the detection performance of LFIA platforms.
引用
收藏
页数:10
相关论文
共 45 条
  • [41] All-printed highly sensitive 2D MoS2 based multi-reagent immunosensor for smartphone based point-of-care diagnosis
    Memoon Sajid
    Ahmed Osman
    Ghayas Uddin Siddiqui
    Hyun Bum Kim
    Soo Wan Kim
    Jeong Bum Ko
    Yoon Kyu Lim
    Kyung Hyun Choi
    Scientific Reports, 7
  • [42] One-step colorimetric isothermal detection of COVID-19 with AI-assisted automated result analysis: A platform model for future emerging point-of-care RNA/DNA disease diagnosis
    Jaroenram, Wansadaj
    Chatnuntawech, Itthi
    Kampeera, Jantana
    Pengpanich, Sukanya
    Leaungwutiwong, Pornsawan
    Tondee, Benyatip
    Sirithammajak, Sarawut
    Suvannakad, Rapheephat
    Khumwan, Pakapreud
    Dangtip, Sirintip
    Arunrut, Narong
    Bantuchai, Sirasate
    Nguitragool, Wang
    Wongwaroran, Suchawit
    Khanchaitit, Paisan
    Sattabongkot, Jetsumon
    Teerapittayanon, Surat
    Kiatpathomchai, Wansika
    TALANTA, 2022, 249
  • [43] A paper-based colorimetric point-of-care testing kit using novel two-dimensional CuBO2 nanoplates for the efficient detection of Vitamin C and fabrication of a highly sensitive optical sensor
    Radhakrishnan, Malavika
    Ravindran, Anjana
    Unnikrishnan, Ajaikrishnan
    Cheviri, Bineesha
    Parambath, Muhammad Javad
    Chandran, Neeli
    Nair, Swapna Shanmukhan
    SURFACES AND INTERFACES, 2024, 55
  • [44] Noninferiority of glucose-6-phosphate dehydrogenase deficiency diagnosis by a point-of-care rapid test vs the laboratory fluorescent spot test demonstrated by copper inhibition in normal human red blood cells
    Baird, J. Kevin
    Dewi, Mewahyu
    Subekti, Decy
    Elyazar, Iqbal
    Satyagraha, Ari W.
    TRANSLATIONAL RESEARCH, 2015, 165 (06) : 677 - 688
  • [45] Fast and Highly Sensitive Fiber-Enhanced Raman Spectroscopic Monitoring of Molecular H2 and CH4 for Point-of-Care Diagnosis of Malabsorption Disorders in Exhaled Human Breath
    Hanf, Stefan
    Boegoezi, Timea
    Keiner, Robert
    Frosch, Torsten
    Popp, Juergen
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 982 - 988