Comparison of computer-assisted sperm analysis and smartphone-applied sperm analysis for evaluation of frozen-thawed bull semen

被引:1
|
作者
Bastan, Ilktan [1 ]
机构
[1] Burdur Mehmet Akif Ersoy Univ, Fac Vet Med, Dept Reprod & Artificial Inseminat, Burdur, Turkiye
关键词
bull semen; CASA; cryopreservation; smartphone-applied sperm analysis; MOTILITY; DEVICE;
D O I
10.1111/rda.14695
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
This study aims to compare the efficacy of computer-assisted sperm analysis (CASA) and smartphone-applied sperm analysis (SASA) in assessing the quality of frozen-thawed bull semen. A total of 75 straws (n = 75) semen samples were used from different production batches of five Holstein bulls. The semen analyses were conducted in three groups: Group I (CASA-37 degrees C), semen samples were evaluated using the CASA system at 37 degrees C (n = 25); Group II (SASA-25 degrees C), semen samples were assessed using the SASA system at a temperature of room heat (25 degrees C) (n = 25); and Group III (SASA-37 degrees C), semen samples were evaluated using the SASA system at 37 degrees C (n = 25). The frozen-thawed bull semen samples were analysed in terms of total motility (TM), progressive motility (PM), immotile, velocity average path (VAP), velocity curve linear (VCL), velocity straight line (VSL) and sperm concentration. There was no significant difference between the groups in terms of spermatozoa concentration (p > .05). However, significant differences among the groups were observed for total motile spermatozoa values (p < .001). Values of progressive motile spermatozoa were lower in Group I and Group II compared to Group III (p < .001). The immotile spermatozoa values were significant between the groups (p < .001) and were found to be proportional to total motile spermatozoa values. Additionally, the VAP, VCL and VSL values were comparable between Group II and Group III, but lower when compared to Group I. In conclusion, the results of the study demonstrate that the Sperm Cell (TM) system can accurately analyse the concentration of frozen-thawed bull semen. The analyses performed at room temperature indicate a parallelism between the PM value and CASA results. However, it is thought that SASA devices require a series of standardization studies in different semen extenders, different sample concentrations and different animal species, analogous to the standardization evolution process of CASA devices in semen analysis.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Birth of a calf after intracytoplasmic sperm injection with frozen-thawed epididymal sperm from a postmortem bull
    Guerrero, C. A.
    Smith, J.
    Lynn, J. W.
    Bondioli, K. R.
    Godke, R. A.
    REPRODUCTION FERTILITY AND DEVELOPMENT, 2008, 20 (01) : 216 - 216
  • [42] Assessing cryocapacitation in frozen-thawed bovine sperm from a commercial bull stud
    Knobbe, M.
    Reese, M.
    Kaproth, M.
    Dobrinski, I.
    Galantino-Homer, H.
    THERIOGENOLOGY, 2008, 70 (03) : 586 - 586
  • [43] Effect of red light-stimulation on the quality of frozen-thawed bull sperm
    Recuero, S.
    Barranco, I.
    Mateo, Y.
    Delgado-Bermudez, A.
    Llavanera, M.
    Rodriguez-Gil, J. E.
    Bonet, S.
    Fernandez-Fuertes, B.
    Yeste, M.
    REPRODUCTION IN DOMESTIC ANIMALS, 2019, 54 : 118 - 118
  • [44] Effect of storage temperatures of bull's epididymis on frozen-thawed sperm quality
    Enrique Valverde-Peralta, Edwin
    Ernesto Argudo-Garzon, Daniel
    Patricio Bueno-Leon, Hernan
    Quintero-Moreno, Armando
    Andres Galarza-Lucero, Diego
    REVISTA CIENTIFICA-FACULTAD DE CIENCIAS VETERINARIAS, 2018, 28 (06): : 454 - 460
  • [45] Comparative transcript profiling of gene expression of fresh and frozen-thawed bull sperm
    Chen, Xiaoli
    Wang, Yonggui
    Zhu, Huabin
    Hao, Haisheng
    Zhao, Xueming
    Qin, Tong
    Wang, Dong
    THERIOGENOLOGY, 2015, 83 (04) : 504 - 511
  • [46] The importance of computer-assisted semen analysis and sperm function testing in an IVF program
    Joshi, N
    Kodwany, G
    Balaiah, D
    Parikh, M
    Parikh, F
    INTERNATIONAL JOURNAL OF FERTILITY AND MENOPAUSAL STUDIES, 1996, 41 (01) : 46 - 52
  • [47] COMPUTER-ASSISTED SEMEN ANALYSIS (CASA) OF EPIDIDYMAL SPERM FROM THE DOMESTIC CAT
    STACHECKI, JJ
    GINSBURG, KA
    LEACH, RE
    ARMANT, DR
    JOURNAL OF ANDROLOGY, 1993, 14 (01): : 60 - 65
  • [48] EVALUATION OF THE CELLTRAK COMPUTER-ASSISTED SPERM ANALYSIS SYSTEM IN COMPARISON TO THE CELLSOFT SYSTEM TO MEASURE HUMAN SPERM HYPERACTIVATION
    HUROWITZ, EH
    LEUNG, A
    WANG, C
    FERTILITY AND STERILITY, 1995, 64 (02) : 427 - 432
  • [49] Computer-assisted sperm analysis of frozen sperm motility after different times of exposure at 15°C
    Guerra, A. Garcia
    Etcheverry, M. P.
    Rodriguez, D.
    Larraburu, G.
    Brogliatti, G. M.
    REPRODUCTION FERTILITY AND DEVELOPMENT, 2008, 20 (01) : 119 - 119
  • [50] Prediction of the fertility of stallion frozen-thawed semen using a combination of computer-assisted motility analysis, microscopical observation and flow cytometry
    Battut, I. Barrier
    Kempfer, A.
    Lemasson, N.
    Chevrier, L.
    Camugli, S.
    THERIOGENOLOGY, 2017, 97 : 186 - 200