Safety of contrast-enhanced ultrasound using microbubbles in human pregnancy: A scoping review

被引:2
|
作者
Dassen, Sophie [1 ]
Monen, Loes [1 ]
Oei, Guid [2 ]
Mischi, Massimo
van Laar, Judith [1 ]
机构
[1] Maxima Med Ctr, Obstet & Gynecol, Run 4600, NL-5500 MB Veldhoven, Netherlands
[2] Tech Univ Eindhoven, Fundamental Perinatol, Eindhoven, Netherlands
来源
关键词
ultrasonography; contrast-enhanced ultrasound; microbubbles; safety; pregnancy; FETAL-GROWTH RESTRICTION; PLACENTAL BLOOD-FLOW; AGENT; ULTRASONOGRAPHY; PERFUSION; INSIGHTS; PRINCIPLES; DOPPLER; BARRIER; MODEL;
D O I
10.1055/a-2351-0747
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Introduction Successful placentation is crucial for fetal development and maintaining a healthy pregnancy. Placental insufficiency can cause a variety of obstetric complications. Despite the many efforts to enhance diagnosing placental insufficiency, no imaging technique has proven satisfactory. A promising imaging technique is contrast-enhanced ultrasound (CEUS) using microbubbles which has proven capable of (micro)vascular imaging. Its use for placental vascularization assessment in human pregnancies remains constrained by limited evidence and safety concerns. This scoping review aims to demonstrate the safety of CEUS used in human pregnancy in the published literature to date. Material and Methods A systematic search using PubMed, Medline, Embase, and Cochrane databases was performed. All studies where contrast-enhanced ultrasound was used in pregnant humans were included. Studies, where there was a planned termination of pregnancy, were excluded. To assess the safety of CEUS during pregnancy, relevant outcomes were divided into the following 3 categories; fetal outcome, maternal outcome, and pregnancy and neonatal outcomes. Results A total of 13 articles were included, in which 256 women underwent CEUS during pregnancy. No clinically significant maternal or fetal adverse events or negative pregnancy or neonatal outcomes associated with CEUS were described. Conclusion Based on our findings, we consider expanding the knowledge of this promising diagnostic technique in future larger clinical studies to be safe and relevant.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Monitoring angiogenesis in human melanoma xenografts using contrast-enhanced ultrasound
    Ro, RJ
    Forsberg, F
    Liu, JB
    James, KM
    Potoczek, M
    Lewin, PA
    Nazarian, LN
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 520 - 523
  • [22] The Value of Contrast-Enhanced Ultrasound in the Diagnosis of Cesarean Scar Pregnancy
    Xiong, Xi
    Yan, Ping
    Gao, Chunyan
    Sun, Qiulei
    Xu, Fenglian
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [23] Microbubbles used for contrast enhanced ultrasound and theragnosis: a review of principles to applications
    Lee H.
    Kim H.
    Han H.
    Lee M.
    Lee S.
    Yoo H.
    Chang J.H.
    Kim H.
    Biomedical Engineering Letters, 2017, 7 (2) : 59 - 69
  • [24] Assessment of hepatocellular carcinoma by contrast-enhanced ultrasound with perfluorobutane microbubbles: comparison with dynamic CT
    Mandai, M.
    Koda, M.
    Matono, T.
    Nagahara, T.
    Sugihara, T.
    Ueki, M.
    Ohyama, K.
    Murawaki, Y.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1002): : 499 - 507
  • [26] A preliminary in vitro assessment of polymer-shelled microbubbles in contrast-enhanced ultrasound imaging
    Sciallero, C.
    Paradossi, G.
    Trucco, A.
    ULTRASONICS, 2012, 52 (03) : 456 - 464
  • [27] Contrast-enhanced Ultrasound and liver imaging: review of the literature
    Ladam-Marcus, V.
    Mac, G.
    Job, L.
    Piot-Veron, S.
    Marcus, C.
    Hoeffel, C.
    JOURNAL DE RADIOLOGIE, 2009, 90 (01): : 93 - 106
  • [28] The evolving role of contrast-enhanced ultrasound in urology: a review
    Andrew Salib
    Ethan Halpern
    John Eisenbrey
    Thenappan Chandrasekar
    Paul H. Chung
    Flemming Forsberg
    Edouard J. Trabulsi
    World Journal of Urology, 2023, 41 : 673 - 678
  • [29] Contrast-enhanced ultrasound in gallbladder disease: a pictorial review
    Gerstenmaier, J. F.
    Hoang, K. N.
    Gibson, R. N.
    ABDOMINAL RADIOLOGY, 2016, 41 (08) : 1640 - 1652
  • [30] Contrast-Enhanced Ultrasound in Vascular Surgery: Review and Update
    Bredahl, Kim
    Mestre, Xavier Marti
    Coll, Ramon Vila
    Ghulam, Qasam Mohammed
    Sillesen, Henrik
    Eiberg, Jonas
    ANNALS OF VASCULAR SURGERY, 2017, 45 : 287 - 293