A self-adaptive model for sensing total phosphorus in natural water bodies using Fourier transform mid-infrared attenuated total reflectance spectroscopy

被引:0
|
作者
Zheng, Shuailin [1 ,2 ]
Zhou, Jianmin [1 ]
Ma, Fei [1 ]
Du, Changwen [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Soil Sci, State Key Lab Soil & Sustainable Agr, Nanjing 211135, Peoples R China
[2] Univ Chinese Acad Sci, Coll Modern Adv Agr Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Phosphorus; Fourier transform infrared attenuated total; reflectance spectroscopy; Self-adaptive PLS model; Natural water bodies; PHOSPHATE ADSORPTION; MULTIVARIATE METHODS; ORGANIC-CARBON; LEAST-SQUARES; SOIL; PREDICTION; TOOL;
D O I
10.1016/j.snr.2024.100230
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
As the most economically developed area in China, the environmental water quality of Guangdong-Hong Kong-Macao Greater Bay Area has received extensive attention, and the spatial variations of total phosphorus (TP) in the Greater Bay were significant, conventional laboratory analysis is difficult to meet the requirements of TP monitoring due to time and cost consuming, and Fourier transform infrared attenuated total reflectance spectroscopy (FTIR-ATR) technology, combined with the self-adaptive partial least squares (SA-PLS) model, was used to determine the TP concentration. The results showed that P-O vibrations were observed in the wavenumber range of 1200-900 cm(-1), and prediction models were established by using this range. For the conventional partial least squares (PLS) model, the R-2, RMSE and RPD were 0.817, 0.022 mg L-1 and 2.335, respectively, while for the SA-PLS model the prediction was improved with the values of 0.965, 0.010 mg L-1, 5.296, respectively, and the SA-PLS mode prediction was satisfied when the TP content in water was more than 0.05 mg L-1. It was found that the TP determination was interfered by sulfate, when the sulfate content was < 100 mg L-1, both SA-PLS and the conventional PLS model could be used for quantitative analysis of TP; when sulfate content was > 100 mg L-1, PLS model could not be used while the SA-PLS model still achieved an excellent prediction. Therefore, FTIR-ATR combined with SA-PLS model can rapidly determine TP in water, providing an alternative strategy for monitoring TP in natural water bodies.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Attenuated total reflectance Fourier transform mid-infrared spectroscopic quantification of sorbitol and sorbose during a Gluconobacter biotransformation process
    Sue Macauley-Patrick
    S. Alison Arnold
    Brendan McCarthy
    Linda M. Harvey
    Brian McNeil
    Biotechnology Letters, 2003, 25 : 257 - 260
  • [22] Detection and Quantification of Urea in Milk Using Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy
    Jha, Shyam Narayan
    Jaiswal, Pranita
    Borah, Anjan
    Gautam, Anuj Kumar
    Srivastava, Neha
    FOOD AND BIOPROCESS TECHNOLOGY, 2015, 8 (04) : 926 - 933
  • [23] Mid-infrared attenuated total reflectance spectroscopy for soil carbon and particle size determination
    Ge, Yufeng
    Thomasson, J. Alex
    Morgan, Cristine L. S.
    GEODERMA, 2014, 213 : 57 - 63
  • [24] Detection and Quantification of Urea in Milk Using Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy
    Shyam Narayan Jha
    Pranita Jaiswal
    Anjan Borah
    Anuj Kumar Gautam
    Neha Srivastava
    Food and Bioprocess Technology, 2015, 8 : 926 - 933
  • [25] Minimally invasive screening for colitis using attenuated total internal reflectance fourier transform infrared spectroscopy
    Titus, Jitto
    Viennois, Emilie
    Merlin, Didier
    Perera, A. G. Unil
    JOURNAL OF BIOPHOTONICS, 2017, 10 (03) : 465 - 472
  • [26] Discrimination of plant pathogenic fungi using attenuated total reflectance Fourier transform infrared spectroscopy and chemometrics
    Vanessa Figueiredo Duarte Vieira
    Estefenson Marques Morais
    José Evando Aguiar Beserra Júnior
    Francisca Diana da Silva Araújo
    European Journal of Plant Pathology, 2024, 168 : 787 - 797
  • [27] ANALYSIS OF DIFFUSION IN POLYMERS USING ATTENUATED TOTAL REFLECTANCE FOURIER-TRANSFORM INFRARED-SPECTROSCOPY
    FIELDSON, GT
    BARBARI, TA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 80 - PMSE
  • [28] Determination of liquid egg composition using attenuated total reflectance Fourier transform infrared spectroscopy and chemometrics
    Uysal, Reyhan S.
    Yilmaz, Ozay Mentes
    Boyaci, Ismail H.
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2019, 99 (07) : 3572 - 3577
  • [29] Discrimination of plant pathogenic fungi using attenuated total reflectance Fourier transform infrared spectroscopy and chemometrics
    Vieira, Vanessa Figueiredo Duarte
    Morais, Estefenson Marques
    Beserra Junior, Jose Evando Aguiar
    Araujo, Francisca Diana da Silva
    EUROPEAN JOURNAL OF PLANT PATHOLOGY, 2024, 168 (04) : 787 - 797
  • [30] Tendinopathy diagnosis and treatment monitoring using attenuated total reflectance-Fourier transform infrared spectroscopy
    Bhattacharjee, Tanmoy T.
    Nicodemo, Mariana C.
    Sant'Anna, Luciana B.
    Lo Schiavo Arisawa, Emilia A.
    Raniero, Leandro
    JOURNAL OF BIOPHOTONICS, 2018, 11 (04)