共 31 条
Pulmonary nodule visualization and evaluation of AI-based detection at various ultra-low-dose levels using photon-counting detector CT
被引:1
|作者:
Jungblut, Lisa
[1
]
Euler, Andre
[1
]
Landsmann, Anna
[1
]
Englmaier, Vanessa
[1
]
Mergen, Victor
[1
]
Sefirovic, Medina
[1
]
Frauenfelder, Thomas
[1
]
机构:
[1] Univ Zurich, Univ Hosp Zurich, Diag & Intervent Radiol, Zurich, Switzerland
关键词:
Photon-counting detector computed tomography;
radiation dosage;
pulmonary nodules;
artificial intelligence;
LUNG-CANCER MORTALITY;
CHEST CT;
COMPUTED-TOMOGRAPHY;
RADIATION;
STANDARD;
D O I:
10.1177/02841851241275289
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Background Radiation dose should be as low as reasonably achievable. With the invention of photon-counting detector computed tomography (PCD-CT), the radiation dose may be considerably reduced. Purpose To evaluate the potential of PCD-CT for dose reduction in pulmonary nodule visualization for human readers as well as for computer-aided detection (CAD) studies. Material and Methods A chest phantom containing pulmonary nodules of different sizes/densities (range 3-12 mm and -800-100 HU) was scanned on a PCD-CT with standard low-dose protocol as well as with half, quarter, and 1/40 dose (CTDIvol 0.4-0.03 mGy). Dose-matched scans were performed on a third-generation energy-integrating detector CT (EID-CT). Evaluation of nodule visualization and detectability was performed by two blinded radiologists. Subjective image quality was rated on a 5-point Likert scale. Artificial intelligence (AI)-based nodule detection was performed using commercially available software. Results Highest image noise was found at the lowest dose setting of 1/40 radiation dose (eff. dose = 0.01mSv) with 166.1 +/- 18.5 HU for PCD-CT and 351.8 +/- 53.0 HU for EID-CT. Overall sensitivity was 100% versus 93% at standard low-dose protocol (eff. dose = 0.2 mSv) for PCD-CT and EID-CT, respectively. At the half radiation dose, sensitivity remained 100% for human reader and CAD studies in PCD-CT. At the quarter radiation dose, PCD-CT achieved the same results as EID-CT at the standard radiation dose setting (93%, P = 1.00) in human reading studies. The AI-CAD system delivered a sensitivity of 93% at the lowest radiation dose level in PCD-CT. Conclusion At half dose, PCD CT showed pulmonary nodules similar to full-dose PCD, and at quarter dose, PCD CT performed comparably to standard low-dose EID CT. The CAD algorithm is effective even at ultra-low doses.
引用
收藏
页码:1238 / 1245
页数:8
相关论文