Pulmonary nodule visualization and evaluation of AI-based detection at various ultra-low-dose levels using photon-counting detector CT

被引:1
|
作者
Jungblut, Lisa [1 ]
Euler, Andre [1 ]
Landsmann, Anna [1 ]
Englmaier, Vanessa [1 ]
Mergen, Victor [1 ]
Sefirovic, Medina [1 ]
Frauenfelder, Thomas [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Diag & Intervent Radiol, Zurich, Switzerland
关键词
Photon-counting detector computed tomography; radiation dosage; pulmonary nodules; artificial intelligence; LUNG-CANCER MORTALITY; CHEST CT; COMPUTED-TOMOGRAPHY; RADIATION; STANDARD;
D O I
10.1177/02841851241275289
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Radiation dose should be as low as reasonably achievable. With the invention of photon-counting detector computed tomography (PCD-CT), the radiation dose may be considerably reduced. Purpose To evaluate the potential of PCD-CT for dose reduction in pulmonary nodule visualization for human readers as well as for computer-aided detection (CAD) studies. Material and Methods A chest phantom containing pulmonary nodules of different sizes/densities (range 3-12 mm and -800-100 HU) was scanned on a PCD-CT with standard low-dose protocol as well as with half, quarter, and 1/40 dose (CTDIvol 0.4-0.03 mGy). Dose-matched scans were performed on a third-generation energy-integrating detector CT (EID-CT). Evaluation of nodule visualization and detectability was performed by two blinded radiologists. Subjective image quality was rated on a 5-point Likert scale. Artificial intelligence (AI)-based nodule detection was performed using commercially available software. Results Highest image noise was found at the lowest dose setting of 1/40 radiation dose (eff. dose = 0.01mSv) with 166.1 +/- 18.5 HU for PCD-CT and 351.8 +/- 53.0 HU for EID-CT. Overall sensitivity was 100% versus 93% at standard low-dose protocol (eff. dose = 0.2 mSv) for PCD-CT and EID-CT, respectively. At the half radiation dose, sensitivity remained 100% for human reader and CAD studies in PCD-CT. At the quarter radiation dose, PCD-CT achieved the same results as EID-CT at the standard radiation dose setting (93%, P = 1.00) in human reading studies. The AI-CAD system delivered a sensitivity of 93% at the lowest radiation dose level in PCD-CT. Conclusion At half dose, PCD CT showed pulmonary nodules similar to full-dose PCD, and at quarter dose, PCD CT performed comparably to standard low-dose EID CT. The CAD algorithm is effective even at ultra-low doses.
引用
收藏
页码:1238 / 1245
页数:8
相关论文
共 31 条
  • [1] Potential of Unenhanced Ultra-Low-Dose Abdominal Photon-Counting CT with Tin Filtration: A Cadaveric Study
    Huflage, Henner
    Grunz, Jan-Peter
    Patzer, Theresa Sophie
    Pannenbecker, Pauline
    Feldle, Philipp
    Sauer, Stephanie Tina
    Petritsch, Bernhard
    Erguen, Sueleyman
    Bley, Thorsten Alexander
    Kunz, Andreas Steven
    DIAGNOSTICS, 2023, 13 (04)
  • [2] First Performance Evaluation of an Artificial Intelligence-Based Computer-Aided Detection System for Pulmonary Nodule Evaluation in Dual-Source Photon-Counting Detector CT at Different Low-Dose Levels
    Jungblut, Lisa
    Bluthgen, Christian
    Polacin, Malgorzata
    Messerli, Michael
    Schmidt, Bernhard
    Euler, Andre
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Martini, Katharina
    INVESTIGATIVE RADIOLOGY, 2022, 57 (02) : 108 - 114
  • [3] Improved Lung Cancer Detection in Ultra Low dose CT with Combined AI-based Nodule Detection and Denoising Techniques
    Lee, Jemyoung
    Park, Jae-Hyun
    Kim, Minsu
    Heo, Changyoung
    Lee, Kyong Joon
    Kim, Hanyoung
    Kim, Jihang
    Kim, Jong Hyo
    INTERNATIONAL WORKSHOP ON ADVANCED IMAGING TECHNOLOGY (IWAIT) 2022, 2022, 12177
  • [4] Improvement of coronary stent visualization using ultra-high-resolution photon-counting detector CT
    Qin, Le
    Zhou, Shanshui
    Dong, Haipeng
    Li, Jiqiang
    Zhang, Ruiyan
    Yang, Chendie
    Liu, Peng
    Xu, Zhihan
    Yan, Fuhua
    Yang, Wenjie
    EUROPEAN RADIOLOGY, 2024, 34 (10) : 6568 - 6577
  • [5] Low Dose Ultra-High Resolution Sinus Imaging Using Photon-Counting Detector CT with Tin Filter
    Rajendran, K.
    Zhou, W.
    Tao, S.
    Voss, B.
    Bruesewitz, M.
    Weaver, J.
    DeLone, D.
    Fletcher, J.
    McCollough, C.
    Leng, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E409 - E409
  • [6] Ultra-Low-Dose Photon-Counting CT Imaging of the Paranasal Sinus With Tin Prefiltration How Low Can We Go?
    Grunz, Jan-Peter
    Petritsch, Bernhard
    Luetkens, Karsten Sebastian
    Kunz, Andreas Steven
    Lennartz, Simon
    Ergun, Suleyman
    Bley, Thorsten Alexander
    Huflage, Henner
    INVESTIGATIVE RADIOLOGY, 2022, 57 (11) : 728 - 733
  • [7] Accuracy of Nodule Volume and Airway Wall Thickness Measurement Using Low-Dose Chest CT on a Photon-Counting Detector CT Scanner
    Dunning, Chelsea A. S.
    Marsh, Jeffrey F., Jr.
    Winfree, Timothy
    Rajendran, Kishore
    Leng, Shuai
    Levin, David L.
    Johnson, Tucker F.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    INVESTIGATIVE RADIOLOGY, 2023, 58 (04) : 283 - 292
  • [8] Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT
    Kaatsch, Hanns Leonhard
    Fulisch, Florian
    Dillinger, Daniel
    Kubitscheck, Laura
    Becker, Benjamin V.
    Piechotka, Joel
    Brockmann, Marc A.
    Froelich, Matthias F.
    Schoenberg, Stefan O.
    Overhoff, Daniel
    Waldeck, Stephan
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (01) : 103 - 108
  • [9] Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT
    Kaatsch, Hanns Leonhard
    Fulisch, Florian
    Dillinger, Daniel
    Kubitscheck, Laura
    Becker, Benjamin, V
    Piechotka, Joel
    Brockmann, Marc A.
    Froelich, Matthias F.
    Schoenberg, Stefan O.
    Overhoff, Daniel
    Waldeck, Stephan
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (02) : 103 - 108
  • [10] Prospective Pilot Evaluation of Radiologists and Computer-aided Pulmonary Nodule Detection on Ultra-low-Dose CT With Tin Filtration
    Takahashi, Edwin A.
    Koo, Chi Wan
    White, Darin B.
    Lindell, Rebecca M.
    Sykes, Anne-Marie G.
    Levin, David L.
    Kuzo, Ronald S.
    Wolf, Matthias
    Bogoni, Luca
    Carter, Rickey E.
    McCollough, Cynthia H.
    Fletcher, Joel G.
    JOURNAL OF THORACIC IMAGING, 2018, 33 (06) : 396 - 401