Experimental study of a novel guided sequential immersion cooling system for battery thermal management

被引:1
|
作者
Zhong, Kaiwei [1 ]
Wang, Changhong [1 ]
Luo, Qingyi [1 ]
Zhang, Zhihui [1 ]
Zheng, Junxin [1 ]
机构
[1] Guangdong Univ Technol, Sch Mat & Energy, Guangzhou 510006, Peoples R China
基金
中国国家自然科学基金;
关键词
Sequential cooling; Immersion cooling; Battery thermal management systems; Lithium-ion battery;
D O I
10.1016/j.applthermaleng.2024.124337
中图分类号
O414.1 [热力学];
学科分类号
摘要
Immersion cooling exhibits superior cooling performance compared to traditional battery thermal management systems (BTMS). However, a significant challenge of immersion cooling is the spatial variation of temperature within both the coolant and lithium-ion batteries (LIBs). This research proposes a guided sequential immersion cooling (GSIC) BTMS to address this issue. Experimental studies were conducted to evaluate the heat dissipation performance of the GSIC structure under various conditions, including extreme loads. The results indicate that under the static flow immersion cooling (SFIC) scheme, cooling the tabs significantly influences the overall performance. Immersing the tabs can reduce the maximum battery temperature by 10.403 degrees C, although the spatial variation of temperature persists. Under forced flow immersion cooling (FFIC) conditions, increasing the coolant flow rate dissipates the heat generated by LIBs more effectively. Even at an extreme discharge rate of 5C, the maximum temperature remains below 45 degrees C. The average temperature reduction at the tabs is greater than the battery body, and with increased flow rates, the temperature difference between the two can be maintained within 1 degrees C under all conditions. As the flow rate keeps increasing, the average temperature at the tabs gets even lower than the battery body at low loads. This demonstrates that the GSIC BTMS can suppress the temperature rise at the tabs, which is a critical heat risk. Moreover, the temperature uniformity of the LIBs module is improved. As the flow rate increases, the temperature difference within the LIBs module decreases when the discharge rates is between 1C and 5C. Theoretical analysis confirms that increasing flow rates for low loads can suppress temperature rise, albeit with increased power consumption and reduced cooling efficiency. High flow rates are more suitable for high load conditions of the LIBs. These results validate the feasibility of the GSIC BTMS and provide new insights for the development of immersion cooling BTMS.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Experimental study of a direct evaporative cooling approach for Li-ion battery thermal management
    Zhao, Rui
    Liu, Jie
    Gu, Junjie
    Zhai, Long
    Ma, Fai
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (08) : 6660 - 6673
  • [42] Experimental study of phase change microcapsule-based liquid cooling for battery thermal management
    Chen, Rong
    Ge, Xin
    Zhong, Ying
    Jiang, Liqin
    Zhang, Guoqing
    Zhang, Jiangyun
    Ke, Xiufang
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 146
  • [43] Experimental study on heat transfer characteristics and Capillary-Assisted enhancement of Dual-Phase immersion battery thermal management system
    Chen, Ke
    Tang, Aikun
    Pan, Jun
    Cai, Tao
    Chen, Xingyu
    Yang, Leiqi
    ENERGY CONVERSION AND MANAGEMENT, 2024, 322
  • [44] Liquid cooling based on thermal silica plate for battery thermal management system
    Wang, Cong
    Zhang, Guoqing
    Meng, Like
    Li, Xinxi
    Situ, Wenfu
    Lv, Youfu
    Rao, Mumin
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2017, 41 (15) : 2468 - 2479
  • [45] The experimental study on a novel integrated system with thermal management and rapid cooling for battery pack based on C6F12O spray cooling in a closed-loop
    Qin, Peng
    Jia, Zhuangzhuang
    Jin, Kaiqiang
    Duan, Qiangling
    Sun, Jinhua
    Wang, Qingsong
    JOURNAL OF POWER SOURCES, 2021, 516
  • [46] Cold plate enabling air and liquid cooling simultaneously: Experimental study for battery pack thermal management and electronic cooling
    Coskun, Turgay
    Cetkin, Erdal
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 217
  • [47] Experimental and numerical investigation of a composite thermal management system for energy storage battery based on air cooling
    Su, Qingzong
    Kang, Fangming
    Li, Jianming
    Ma, Qing
    Wang, Yaxiong
    Duan, Jianguo
    Zhang, Chao
    APPLIED THERMAL ENGINEERING, 2025, 262
  • [48] Transient heat dissipation performance investigation on the battery thermal management system based on S-CO2 immersion cooling
    Dai, Hongsong
    Yang, Chenxu
    Zhang, Feng
    Liao, Gaoliang
    Zhang, Bolun
    ENERGY, 2025, 318
  • [49] Experimental investigation of the thermal management system of a battery pack using a thermoelectric air-cooling module
    Sirikasemsuk, Sarawut
    Wiriyasart, Songkran
    Naphon, Paisarn
    HEAT TRANSFER, 2022, 51 (07) : 6384 - 6402
  • [50] Experimental study on the bottom liquid cooling thermal management system for lithium-ion battery based on multichannel flat tube
    Ren, Ruyang
    Zhao, Yaohua
    Diao, Yanhua
    Liang, Lin
    APPLIED THERMAL ENGINEERING, 2023, 219