Identifying Critical Failures in PV Systems Based on PV Inverters' Monitoring Unit: A Techno-Economic Analysis

被引:0
|
作者
Monteiro, Filipe [1 ]
Sarquis, Eduardo [2 ]
Branco, Paulo [2 ]
机构
[1] Univ Lisbon, Inst Super Tecn, P-1049001 Lisbon, Portugal
[2] Univ Lisbon, IDMEC, Inst Super Tecn, P-1049001 Lisbon, Portugal
关键词
failure mode and effects analysis (FMEA); photovoltaic system; reliability; monitoring; PV Inverter; FAULT-DETECTION;
D O I
10.3390/en17184738
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Recent advancements in power electronics have significantly improved photovoltaic (PV) inverters by equipping them with sophisticated monitoring capabilities. These enhancements provide economic advantages by facilitating swift failure detection and lowering monitoring costs. Educating users on the economic repercussions of undetected failures in specific inverter monitoring systems is crucial. This paper introduces a novel metric, "Cost of Detection", which assesses the financial impact of failures, considering the repair expenses and the "quality" of the monitoring system in place. The study analyzed fifteen inverter monitoring solutions, focusing on the variance in alerts generated by the manufacturers' standard and extra monitoring features. Employing the Failure Mode and Effects Analysis (FMEA) method, alerts were prioritized based on their importance for two PV system scenarios: a low-power residential system (5 kWp) and a medium-power industrial/commercial system (100 kWp). Lisbon, Rome, and Berlin were chosen as the locations for these systems. The economic impact of system failures is evaluated annually for each capacity and city. Given the differing costs and annual yields, comparing their economic performance over time is essential. This comparison utilizes the Net Present Value (NPV), which estimates an investment's worth by calculating the present value of all cash flows. The investment assessment includes only the costs of inverters and optimizers, excluding O&M expenses, licenses, and fees. Over five years, a higher NPV signifies a more economically advantageous solution. For residential systems, string inverters with optimizers have the highest NPV, surpassing those without optimizers by 17% across all three cities. The optimal monitoring solution in the industrial/commercial context was a string inverter with one optimizer for every two panels. Here, Rome emerged as the location with the most substantial NPV increase of 50%, followed by Berlin with 33% and Lisbon with 28%.
引用
收藏
页数:23
相关论文
共 50 条
  • [21] Techno-economic sizing analysis of solar PV system for Domestic Refrigerators
    Verma, Jai Kishor
    Dondapati, Raja Sekhar
    INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 286 - 292
  • [22] Techno-economic and environmental analysis of PV power plants in Northern Cyprus
    Abbasoglu, Serkan
    ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2011, 28 (01): : 357 - 368
  • [23] Techno-Economic Analysis of Solar Power Plants in Kuwait: Modelling the Performance of PV and CSP Systems
    Althuwaini, Yaqoub E. Y. Y. E.
    Philbin, Simon P.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2021, 11 (04): : 2009 - 2024
  • [24] Techno-Economic Analysis of Grid-connected Rooftop Solar PV Systems in Saudi Arabia
    Aldahmashi, Nasser
    Khan, Yasin
    Alamoud, Abdulrahman
    2021 IEEE 48TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2021, : 2217 - 2221
  • [25] Techno-economic optimization of photovoltaic (PV)-inverter power sizing ratio for grid-connected PV systems
    Hazim, Hazim Imad
    Baharin, Kyairul Azmi
    Gan, Chin Kim
    Sabry, Ahmad H.
    RESULTS IN ENGINEERING, 2024, 23
  • [26] Techno-Economic Feasibility of the Use of Floating Solar PV Systems in Oil Platforms
    Veliathur Chinnasamy Srinivasan, Chellapillai
    Soori, Prashant Kumar
    Ghaith, Fadi A.
    SUSTAINABILITY, 2024, 16 (03)
  • [27] Techno-economic comparison of PV and diesel systems for telecommunications and aviation navigational AIDS
    AbleThomas, U
    Hill, R
    CONFERENCE RECORD OF THE TWENTY FIFTH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 1996, 1996, : 1481 - 1484
  • [28] Control and Techno-Economic Analysis of PV-Diesel-Battery based Hybrid Microgrid System
    Barua, Ashutosh
    Jain, Arvind Kumar
    Gupta, Manish
    Mishra, Pankaj Kumar
    2017 CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY (CICT), 2017,
  • [29] Techno-economic and Environmental Analysis of a 2.5 MW Solar PV Based Power Plant in Bangladesh
    Redwan, Rahat
    Khan, Md. Sabid
    Seema, Sanjida Akter
    Roy, Chanchal
    Hasan, Mahmudul
    Chowdhury, Nahid-Ur-Rahman
    PROCEEDINGS OF 2024 7TH INTERNATIONAL CONFERENCE ON DEVELOPMENT IN RENEWABLE ENERGY TECHNOLOGY, ICDRET 2024, 2024,
  • [30] Techno-Economic Analysis of a Hybrid CSP/PV Plants in the Eastern Region of Morocco
    Hassani S.E.
    Ouali H.A.L.
    Moussaoui M.A.
    Mezrhab A.
    Applied Solar Energy (English translation of Geliotekhnika), 2021, 57 (04): : 297 - 309