Operational uptime and other measures of performance of an open car park in fire

被引:0
|
作者
Wegrzynski, Wojciech [1 ]
Jaminska-Gadomska, Paulina [1 ]
Miechowka, Bartosz [1 ]
Krajewski, Grzegorz [1 ]
机构
[1] Inst Tech Budowlanej, Filtrowa 1, PL-00611 Warsaw, Poland
关键词
Performance-based design; Smoke management; CFD; Wind; CFD SIMULATION; WIND; VENTILATION; SMOKE;
D O I
10.1016/j.firesaf.2024.104209
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
192 coupled wind and fire CFD simulations were performed using ANSYS Fluent to study the wind and fire interaction in an open car park. The natural ventilation was insufficient for removal of smoke and heat for the majority of investigated fires. Blockage effect was observed for wind directions parallel to the open walls, which resulted in reduced smoke removal and higher smoke temperatures. With known probabilities of all the investigated wind speed and directions, we have estimated the percentage of time in which fire outcomes are acceptable. This value was coined as the car park operational uptime, and was 84.9 % -92.8 % in relation to the fire with HRR = 1.4 MW; 36.5 % -56.1 % at 4.0 MW; 34.1 % -54.4 % at 6.0 MW and 12.13 -25.5 % at 8.8 MW. In 6.22 % of wind cases, the velocity inside the car park exceeded 3.0 m/s, which could potentially contribute to the growth of the fire. Limitations of the study include the assumed wind probability distribution relevant to the Warsaw region, the single location of the fire used in the assessment and the implicit modelling of topography and architecture through an introduced wind profile and terrain roughness model.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Thermo-mechanical analysis of an underground car park structure exposed to fire
    Annerel, E.
    Taerwe, L.
    Merci, B.
    Jansen, D.
    Bamonte, P.
    Felicetti, R.
    FIRE SAFETY JOURNAL, 2013, 57 : 96 - 106
  • [22] LARGE - SCALE FIRE TEST WITH A PASSENGER CAR IN AN OPEN AREA
    Dvorak, Otto
    Wald, Frantisek
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2015, 24 (02):
  • [23] DESIGN OF STEEL AND COMPOSITE OPEN CAR PARKS UNDER FIRE
    Haremza, C.
    Santiago, A.
    da Silva, L. Simoes
    ADVANCED STEEL CONSTRUCTION, 2013, 9 (04): : 350 - 368
  • [24] Thermal response of steel framing members in open car park fires
    Xia YAN
    Marion CRARLIER
    Thomas GERNAY
    Frontiers of Structural and Civil Engineering, 2022, 16 (09) : 1071 - 1088
  • [25] Thermal response of steel framing members in open car park fires
    Yan, Xia
    Charlier, Marion
    Gernay, Thomas
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2022, 16 (09) : 1071 - 1088
  • [26] Thermal response of steel framing members in open car park fires
    Xia Yan
    Marion Charlier
    Thomas Gernay
    Frontiers of Structural and Civil Engineering, 2022, 16 : 1071 - 1088
  • [27] Operational Performance of Sustainable Measures in Public Buildings
    Abdallah, Moatassem
    El-Rayes, Khaled
    Liu, Liang
    JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT, 2013, 139 (12)
  • [28] Real-time visualization of operational performance measures of arterial highway using open crowdsourced data
    Kidando E.
    Kitali A.E.
    Moses R.
    Ozguven E.E.
    Advances in Transportation Studies, 2020, 51 : 47 - 62
  • [29] Cynicism and Other Post ideological Half Measures in South Park
    Groening, Stephen
    LOGOS, 2012, (02): : 215 - +
  • [30] FIRE AND OTHER DISTURBANCES OF THE FORESTS IN MOUNT RAINIER NATIONAL-PARK
    HEMSTROM, MA
    FRANKLIN, JF