Effect of Heat Exchanger and Capillary Geometry on the Performance of Joule-Thomson Refrigerators Operating With Different Mixtures

被引:0
|
作者
Dasari, Venkatesh [1 ]
Venkatarathnam, G. [1 ,2 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Refrigerat & Air Conditioning Lab, Chennai 600036, Tamil Nadu, India
[2] Indian Inst Technol, Sch Sustainabil, Chennai 600036, Tamil Nadu, India
关键词
J-T cryocoolers; heat exchangers; low temperature refrigerators; two-phase heat transfer; TRANSFER COEFFICIENTS; FLOW; OPTIMIZATION; CONDUCTION;
D O I
10.1115/1.4065721
中图分类号
O414.1 [热力学];
学科分类号
摘要
Joule-Thomson (J-T) refrigerators or J-T cryocoolers are extensively used in many low-temperature applications. J-T refrigerators operating with nitrogen-hydrocarbon (N2-HC) refrigerant mixtures offer several advantages, such as low operating pressures (<20 bar), high exergy efficiency, no moving parts in the cold section, and low cost. The cooling power or cooling capacity of the J-T refrigerator depends on the hardware used as well as the refrigerant composition. The proposed work focuses on estimating the cooling capacity of a mixed refrigerant J-T (MRJ-T) refrigerator of the given hardware and specified refrigerant. An iterative steady-state full-cycle simulation procedure has been presented in this work to simulate the complete system and estimate the cooling capacity, taking into account the possibility of choking of the expansion capillary. Some of the results have been validated against experimental results of an MRJ-T refrigerator available in the open literature. Details of the simulation model and the results of our studies on the prediction of stable operating range, maximum cooling capacity, the effect of heat exchanger geometry, expansion capillary geometry, mixture composition, and choking of the refrigerant mixture on the performance of an MRJ-T refrigerator are presented in this article.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] EFFECT OF WORKING GAS AND HEAT EXCHANGER DIMENSIONS ON JOULE THOMSON MICROCOOLER PERFORMANCE
    Kuwamoto, Masashi
    Widyaparaga, Adhika
    Sakoda, Naoya
    Kohno, Masamichi
    Takata, Yasuyuki
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON INNOVATIVE MATERIALS FOR PROCESSES IN ENERGY SYSTEMS 2010 (IMPRES2010): FOR FUEL CELLS, HEAT PUMPS AND SORPTION SYSTEMS, 2010, : 203 - 207
  • [22] INVESTIGATIONS ON TWO-PHASE HEAT EXCHANGER FOR MIXED REFRIGERANT JOULE-THOMSON CRYOCOOLER
    Ardhapurkar, P. M.
    Sridharan, Arunkumar
    Atrey, M. D.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 706 - 713
  • [23] Effects of operating conditions and geometries on the performance of nitrogen ejectors for Joule-Thomson cooling
    Cao, Haishan
    Geng, Lihong
    Meng, Qinghang
    Li, Junming
    Jiang, Peixue
    APPLIED THERMAL ENGINEERING, 2022, 212
  • [25] Performance prediction of a distributed Joule-Thomson effect cooler with pillars
    Wang, Jia
    Cui, Xiaoyu
    Geng, Hui
    She, Hailong
    Chang, Zhihao
    APPLIED THERMAL ENGINEERING, 2023, 218
  • [26] The Joule-Thomson effect and heat capacity at constant pressure for air.
    Bridgeman, OC
    PHYSICAL REVIEW, 1929, 34 (03): : 527 - 533
  • [27] THE JOULE-THOMSON EFFECT AND THE SPECIFIC HEAT AT CONSTANT PRESSURE OF CARBON DIOXIDE
    DEGROOT, SR
    MICHELS, A
    PHYSICA, 1948, 14 (04): : 218 - 222
  • [28] Numerical simulation of tubes-in-tube heat exchanger in a mixed refrigerant Joule-Thomson cryocooler
    Damle, R. M.
    Ardhapurkar, P. M.
    Atrey, M. D.
    26TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE & INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2016, 2017, 171
  • [29] Optimization of Joule-Thomson cryocooler heat exchanger using one-dimensional numerical modeling
    Baki, Murat
    Okutucu-Ozyurt, Tuba
    Sert, Cuneyt
    CRYOGENICS, 2019, 104
  • [30] Thermodynamic optimization of the recuperative heat exchanger for Joule-Thomson cryocoolers using response surface methodology
    Liu, Yingwen
    Liu, Liu
    Liang, Lili
    Liu, Xin
    Li, Jiapeng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 : 155 - 165