Biomechanical evaluation of a central collinear entry reconstruction nail for femoral neck fracture prophylaxis

被引:0
|
作者
Shah, Sapan [1 ]
Huang, Dave T. [1 ,2 ]
Marecek, Geoffrey [1 ]
Huang, Kevin [1 ]
Metzger, Melodie F. [1 ,2 ,3 ]
机构
[1] Cedars Sinai Med Ctr, Dept Orthopaed Surg, Los Angeles, CA USA
[2] Cedars Sinai Med Ctr, Orthopaed Biomech Lab, Los Angeles, CA USA
[3] Cedars Sinai Med Ctr, Dept Orthoped Surg, Orthoped Biomech Lab, 8700 Beverly Blvd,Davis Bldg Rm 6006, Los Angeles, CA 90048 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2024年 / 55卷 / 08期
关键词
Femoral neck; Prophylactic fixation; Central collinear; Piriformis; Trochanteric; PROXIMAL FEMUR FRACTURES; POINT;
D O I
10.1016/j.injury.2024.111640
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Reconstruction nails are commonly used to treat proximal femur fractures, with cephalic screw placement for femoral neck "prophylaxis" becoming standard practice. These implants are traditionally introduced through piriformis fossa (PF) or greater trochanter (GT) entry portals. A third "central collinear" (CC) portal has been proposed that allows entry along the femoral anatomic axis and central placement of cephalic screws. The present study aimed to quantify and compare the CC portal femoral neck strength with the two traditional (PF and GT) entry portals. Materials and Methods: Eighteen cadaveric femur specimens (nine matched pairs) were divided into three groups using a balanced incomplete block design to control for variations in age and sex: (1) GT, (2) CC, and (3) PF entry points. Specimens and implants were cut to a standard length and instrumented with straight or valgus bend nails of appropriate laterality and two cephalic screws. Specimens were mounted on a custom jig replicating load distribution along the mechanical axis. A 100 N compressive preload was applied to the femoral head, followed by loading to failure at a rate of 10 mm/s until fracture, indicated by 30 % drop in axial force. Results: The three entry points did not differ in load-to-failure: GT (6378.7 +/- 1494.9 N), P (6912.4 +/- 4924.1 N) and CC (7044.2 +/- 2911.4 N) (P = 0.948) or maximum displacement, stiffness, and toughness. Most PF specimens failed at the basicervical neck, whereas most GT specimens failed at the subcapital neck; these differences were not significant. CC specimens failed evenly split between subcapital and basicervical. Conclusion: There were no significant difference in femoral neck load-to-failure after placement of a reconstruction nail through a CC entry portal when compared to both GT and PF entry. Clinically, this suggests the CC entry portal is a viable option when clinical considerations warrant its use.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
    Wang, Chaofeng
    Duan, Ning
    Li, Zhong
    Ma, Teng
    Zhang, Kun
    Wang, Qian
    Huang, Qiang
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [32] Novel slide compression anatomic plates of the femoral neck for treating unstable femoral neck fracture: A biomechanical study
    Li, Jia
    Yin, Pengbin
    Li, Jiantao
    Zhao, Zhe
    Zhao, Jingxin
    Cui, Xiang
    Lyu, Houchen
    Zhang, Licheng
    Tang, Peifu
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (05) : 1088 - 1096
  • [33] Finite element analysis of basicervical femoral neck fracture treated with proximal femoral bionic nail
    Cheng, Xiaodong
    Yang, Yanjiang
    Zhu, Jian
    Li, Guimiao
    Chen, Wei
    Wang, Juan
    Zhang, Qi
    Zhang, Yingze
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [34] Finite element analysis of basicervical femoral neck fracture treated with proximal femoral bionic nail
    Xiaodong Cheng
    Yanjiang Yang
    Jian Zhu
    Guimiao Li
    Wei Chen
    Juan Wang
    Qi Zhang
    Yingze Zhang
    Journal of Orthopaedic Surgery and Research, 18
  • [35] Biomechanical assessment of the cannulated posterosuperior screw IOI in femoral neck fracture
    Zhang, Jian
    Lou, Zhiyuan
    Tang, Xin
    ASIAN JOURNAL OF SURGERY, 2023, 46 (08) : 3316 - 3317
  • [36] Biomechanical Evaluation of the Modified Cannulated Screws Fixation of Unstable Femoral Neck Fracture with Comminuted Posteromedial Cortex
    Liu, Jingwen
    Zhang, Baokun
    Yin, Bohao
    Chen, Hongchi
    Sun, Hui
    Zhang, Wei
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [37] CENTRAL ACETABULAR FRACTURE WITH IPSILATERAL DISPLACED FRACTURE OF THE FEMORAL-NECK
    HIGGS, RJED
    NEWMAN, AS
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1993, 63 (10): : 828 - 830
  • [38] Radiological evaluation of intertrochanteric fracture fixation by the proximal femoral nail
    Herman, Amir
    Landau, Yair
    Gutman, Gabriel
    Ougortsin, Vladislav
    Chechick, Aharon
    Shazar, Nachshon
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06): : 856 - 863
  • [39] Fracture Neck of Femur with Proximal Femoral Nail Antirotation Insitu: A Rare Case
    Krishnamurthy, Sunil Lakshmipura
    Kamath, Surendra Umesh
    Annappa, Rajendra
    Guduru, Aditya Vardhan
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (03) : RD01 - RD02
  • [40] Femoral neck fracture in an arthrodesed hip treated by a supracondylar intramedullary locked nail
    Wulke, AP
    Mader, K
    Pennig, D
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (02) : 116 - 118