Intra-rater and Inter-rater Reliability of the Commander Pressure Algometer in Greek Patients With Chronic Neck Pain

被引:0
|
作者
Skordis, Charalampos [1 ]
Liaskou, Christina [1 ]
Papagiakoumou, Evangelia [1 ]
Sotiropoulos, Spyridon [1 ]
Plavoukou, Theodora [1 ]
Karakasidou, Palina [1 ]
Georgoudis, George [1 ]
机构
[1] Univ West Attica UNIWA, Physiotherapy Dept, Athens, Greece
关键词
commander; non-specific chronic neck pain; greek patients; inter-rater reliability; intra-rater reliability; pressure algometer; pressure pain threshold (ppt); SHORT-FORM; THRESHOLD; REPEATABILITY; INDIVIDUALS; SENSITIVITY; ASSOCIATION; VALIDITY; MUSCLES; PEOPLE;
D O I
10.7759/cureus.66350
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Non-specific chronic neck pain (NSCNP) is a musculoskeletal disorder that affects 45%-54% of the general population. There is a strong correlation between patient-reported pain and mechanical pain pressure threshold (PPT) measured with an algometer. Purpose This study aims to investigate the intra- and inter-rater reliability of the Commander algometer in Greek NSCNP patients, in an urban primary care setting. Methods Thirty-three patients (22 women and 11 men) suffering from NSCNP (>3 months), the majority (42.4%) between the ages of 50 years and 59 years and overweight, were measured bilaterally both at the neck (mastoid, trapezius head-insertion and mid-portion, C5-C6 facet, insertion of levator scapula) and at the control areas (mid-deltoid and tibialis anterior) using the Commander algometer. Measurements were taken twice over a span of six days, by two raters, in a primary care setting. Intraclass correlation coefficient (ICC) statistics were used as measures of reliability (p = 0.05). Results Intra-rater reliability was "moderate to good" for both raters. ICC values for PPT at the seven bilaterally measured sites varied between 0.67 and 0.86 for the first rater (p < 0.001) and 0.64 and 0.82 for the second rater (p < 0.003). The inter-rater reliability was "moderate to excellent" (ICC = 0.68-0.92) in the first measurement (T1) and "moderate to good" (ICC = 0.68 to 0.89) in the second measurement (T2). Conclusion This study supports the intra- and inter-rater reliability of the Commander algometer in detecting reliably the mechanical PPT, in Greek NSCNP patients, as measured according to the procedures and methodology followed throughout this study.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Introducing a new definition of a near fall: Intra-rater and inter-rater reliability
    Maidan, I.
    Freedman, T.
    Tzemah, R.
    Giladi, N.
    Mirelman, A.
    Hausdorff, J. M.
    GAIT & POSTURE, 2014, 39 (01) : 645 - 647
  • [22] THE INTER-RATER AND INTRA-RATER RELIABILITY ANALYSIS OF WORKPLACE ERGONOMIC RISK ASSESSMENT
    Rohani, Jafri Mohd.
    Adeyemi, Ademola James
    Abd Aziz, Roseni
    Rani, Mat Rebi Abdul
    JURNAL TEKNOLOGI, 2018, 80 (01): : 53 - 59
  • [23] Intra-Rater and Inter-Rater Reliability of Pressure Pain Algometry of the Sural and Tibial Nerves in Asymptomatic Elite Youth Footballers
    Richards, Daniel
    Jones, Simon
    Jeffery, Josh
    Lowe, Matthew
    Godwin, Mark
    Willett, Matthew
    SPORTS, 2021, 9 (09)
  • [24] Inter-rater and intra-rater reliability outcomes of a rapid bacteria counting system with pressure ulcer samples
    Nakagami, G.
    Mori, M.
    Yoshida, M.
    Kitamura, A.
    Hayashi, A.
    Miyagaki, T.
    Sasaki, S.
    Sugama, J.
    Sanada, H.
    JOURNAL OF WOUND CARE, 2017, 26 (02) : S27 - S31
  • [25] Inter-rater and intra-rater reliability of the Brief-BESTest in people with chronic obstructive pulmonary disease
    Leung, Regina Wai Man
    Alison, Jennifer A.
    McKeough, Zoe J.
    CLINICAL REHABILITATION, 2019, 33 (01) : 104 - 112
  • [26] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Wei, Chin-Hung
    Shen, Shih-Chiang
    Duh, Yih-Cherng
    Tsai, Kuei-Yen
    Chen, Hsin-An
    Huang, Shih-Wei
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (09): : 6586 - 6591
  • [27] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Chin-Hung Wei
    Shih-Chiang Shen
    Yih-Cherng Duh
    Kuei‐Yen Tsai
    Hsin-An Chen
    Shih-Wei Huang
    Surgical Endoscopy, 2022, 36 : 6586 - 6591
  • [28] Tibial speed of sound in extremely preterm infants: inter-rater and intra-rater reliability
    Lopez, M. Romero
    Tibe, C.
    Naik, M.
    Yu-Carr, M.
    Bachim, A.
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2025, 369
  • [29] Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers
    Greene, Amanda
    Lasner, Andrea
    Deu, Rajwinder
    Oliphant, Seth
    Johnson, Kenneth
    PHYSIOTHERAPY THEORY AND PRACTICE, 2019, 35 (01) : 94 - 99
  • [30] Inter-rater and Intra-rater Reliability of a Mobile App Method to Measure Lumbar Lordosis
    Gnanasigamani, Jency Thangasheela
    Ramalingam, Vinodhkumar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)