Skin Adhesive Tapes: An Effective Wound Closure Method for Percutaneous Vertebral Body Stenting

被引:0
|
作者
Yang, Cassie [1 ]
Qiu, Theophilus [2 ]
Cheong, Reuben Soh Chee [1 ]
Yang, Youheng Ou [1 ]
机构
[1] Sengkang Gen Hosp, Orthopaed Surg, Singapore, Singapore
[2] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore, Singapore
关键词
orthopedic spine surgery; surgery spine; skin adhesive tapes; wound healing; vertebral body stent; VERTEBROPLASTY; KYPHOPLASTY; FRACTURES;
D O I
10.7759/cureus.67859
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Skin adhesive tapes (SATs) are hypoallergenic adhesive tapes commonly used for wound closure in percutaneous vertebroplasty (PVP). Vertebral body stenting (VBS) is a metallic balloon-expandable stent used to treat vertebral body fractures. Its balloon and stent deployment involves a larger stab incision and pedicle bore tract than PVP, increasing the risk of bleeding and wound complications. This study evaluated the outcome and complications of VBS wound closure with SAT and the reasons for conversion to conventional suture closure (SC). Material and methods A retrospective series of patients who underwent VBS from May 2019 to March 2021 were identified from review of computerized medical records. Data were collected for wound closure method, reason for SC, number of operative levels, postoperative wound complications of contact dermatitis, tension blisters, tape dislodgement, surgical site infection, wound dehiscence, symptomatic hematoma and return to operating theater. The wounds were assessed for complete healing and cosmesis at outpatient follow-up visits. Results A total of 36 patients were identified. SAT closure was performed in 33 (91.6%) patients, while SC was performed in three (8.3%) patients. Unplanned conversion to SC was required in two (5.5%) patients due to continued intraoperative wound bleeding, while one (2.7%) patient had planned SC as part of a staged operation. Uneventful closures occurred in 32 (97.0%) of SAT closures. One (3%) SAT closure patient developed postoperative blood-soaked dressings and tape dislodgement, requiring reapplication of the SATs at the ward with uneventful recovery thereafter. No patient with SAT closure developed contact dermatitis, tension blisters, surgical site infection, wound dehiscence, symptomatic hematoma, or required return to theater. All SAT closure patients had complete wound healing at outpatient follow-up at six weeks. No SAT closure was found to be cosmetically unacceptable or required wound revision for any reason at up to one year postoperatively. Conclusion SATs are a safe and reliable means of wound closure for VBS. Conversion to SC due to continued intraoperative wound site bleeding is rarely required.
引用
收藏
页数:9
相关论文
共 49 条
  • [31] Effective Wound Closure With a New Two-Component Wound Closure Device (Prineo™) in Excisional Body-Contouring Surgery: Experience in Over 200 Procedures
    Georg M. Huemer
    Manfred Schmidt
    Gudrun H. Helml
    Maziar Shafighi
    Karin M. Dunst-Huemer
    Aesthetic Plastic Surgery, 2012, 36 : 382 - 386
  • [32] Effective Wound Closure With a New Two-Component Wound Closure Device (Prineo™) in Excisional Body-Contouring Surgery: Experience in Over 200 Procedures
    Huemer, Georg M.
    Schmidt, Manfred
    Helml, Gudrun H.
    Shafighi, Maziar
    Dunst-Huemer, Karin M.
    AESTHETIC PLASTIC SURGERY, 2012, 36 (02) : 382 - 386
  • [33] Comparison of 2-octyl cyanoacrylate skin adhesive and interrupted polypropylene sutures for wound closure in total ankle arthroplasty
    Lee, Gun-Woo
    Kwak, Woo Kyoung
    Lee, Keun-Bae
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [34] Comparison of 2-octyl cyanoacrylate skin adhesive and interrupted polypropylene sutures for wound closure in total ankle arthroplasty
    Gun-Woo Lee
    Woo Kyoung Kwak
    Keun-Bae Lee
    Journal of Orthopaedic Surgery and Research, 16
  • [35] Comparison of clinical and radiological outcomes of vertebral body stenting versus percutaneous kyphoplasty for the treatment of osteoporotic vertebral compression fracture: A systematic review and meta-analysis
    Zhang, Ting
    Peng, Yinxiao
    Li, Jun
    JOINT DISEASES AND RELATED SURGERY, 2024, 35 (01): : 218 - 230
  • [36] Infant Skin Friendly Adhesive Hydrogel Patch Activated at Body Temperature for Bioelectronics Securing and Diabetic Wound Healing
    Jiang, Yanan
    Zhang, Xin
    Zhang, Wei
    Wang, Menghao
    Yan, Liwei
    Wang, Kefeng
    Han, Lu
    Lu, Xiong
    ACS NANO, 2022, 16 (06) : 8662 - 8676
  • [37] Cutting and shutting - a novel method for wound closure following excision biopsy in areas of high skin tension
    Ali, S. R.
    Mohamedbhai, H.
    Ibrahim, A.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2018, 100 (07) : 586 - 586
  • [38] Comparison of 2-Octyl Cyanoacrylate Topical Skin Adhesive and Simple Interrupted Nylon Sutures for Wound Closure in Ankle Fracture Surgery
    Park, Young Hwan
    Song, Jong Hyub
    Choi, Gi Won
    Kim, Hak Jun
    FOOT & ANKLE INTERNATIONAL, 2018, 39 (11) : 1283 - 1289
  • [39] Long-term results of suture-free cutanous wound closure in head and neck incisions with octylcyanoacrylate topival skin adhesive
    Rojas, WE
    Di Martino, E
    Harandi, B
    Westhofen, M
    LARYNGO-RHINO-OTOLOGIE, 2002, 81 (09): : 644 - 648
  • [40] Use of 2-octyl-cyanoacrylate skin adhesive (dermabond) for wound closure following reduction mammaplasty: A prospective, randomized intervention study
    Nipshagen, Martine D.
    Hage, J. Joris
    Beekman, Werner H.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 122 (01) : 10 - 18