Electrochemical sensors based on biomimetic magnetic molecularly imprinted polymer for selective quantification of methyl green in environmental samples

被引:70
|
作者
Khan, Sabir [1 ,2 ]
Wong, Ademar [1 ,2 ]
Boldrin Zanoni, Maria Valnice [1 ,2 ]
Taboada Sotomayor, Maria Del Pilar [1 ,2 ]
机构
[1] Univ Estadual Paulista UNESP, Dept Quim Analit, Inst Quim, Araraquara, SP, Brazil
[2] Natl Inst Alternat Technol Detect Toxicol Evaluat, Araraquara, SP, Brazil
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2019年 / 103卷
基金
巴西圣保罗研究基金会;
关键词
Magnetic-MIP; Environmental analysis; Electrochemical sensor; Methyl green dye; AQUEOUS-SOLUTION; GRAPHENE OXIDE; DYE; ACID; MIP; PRECONCENTRATION; WASTEWATERS; ADSORPTION; REMOVAL;
D O I
10.1016/j.msec.2019.109825
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A new biomimetic sensor was prepared on carbon paste with magnetic molecularly imprinted polymer (mag-MIP) for sensitive and selective detection of methyl green dye. The mag-MIP was synthesized using a functional monomer that was selected before by computational simulation. A mag-NIP (magnetic non-imprinted polymer) control material was also prepared for comparative purposes. Modeling adsorption studied revealed that the dye polymer interface followed pseudo-first order kinetics and that maximum adsorption (Q(m)) of the dye on mag-MIP was 3.13 mg g(-1), while the value for mag-NIP was 1.58 mg g(-1). The selective material was used as a sensing spot in fabrication of an electrochemical sensor based on modified carbon paste. For electrochemical analysis, the best achievement of the sensor was acquire by tack together a paste with 6.7% (w/w) of mag-MIP and using square-wave adsorptive anodic stripping voltammetry (SWAdASV) in 0.1 mol L-1 phosphate buffer (pH 7.0), with an applied potential (E-appl) of 0.3 V vs. Ag vertical bar AgClsat during an adsorption time (T-ads) of 120 s. The results were obtained under optimized conditions in which sensor provided a linear concentration range of methyl green from 9.9 x 10(-8) to 1.8 x 10(-6) mol L-1, with a limit of detection (LOD) of 1.0 x 10(-8) mol L-1 and a satisfactory relative standard deviation (RSD) of 4.3% (n = 15). The proposed sensor was applying using two spiked river water samples, obtaining recoveries ranging from 93% to 103%. The proposed method exhibits excellent precision also high reliability and proved to be an alternative method for the quantification of methyl green in real samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Molecularly imprinted polymer (MIP) based electrochemical sensors and their recent advances in health applications
    Wang, Lue
    Zhang, Wei
    SENSORS AND ACTUATORS REPORTS, 2023, 5
  • [42] Development of highly selective and sensitive molecularly imprinted polymer-based electrochemical sensors for tolvaptan assay in tablets and serum
    Karadurmus, Leyla
    Budak, Fatma
    Cetinkaya, Ahmet
    Atici, Esen Bellur
    Ozkan, Sibel A.
    ANALYTICAL METHODS, 2023, 15 (40) : 5316 - 5322
  • [43] Selective electrochemical determination based on magnetic molecularly imprinted polymers for albumin detection
    Leepheng, Piyawan
    Limthin, Dalawan
    Onlaor, Korakot
    Tunhoo, Benchapol
    Thiwawong, Thutiyaporn
    Suramitr, Songwut
    Phromyothin, Darinee
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (SD)
  • [44] Fabrication of an Electrochemical Sensor Based on Molecularly Imprinted Polymer for the Selective Determination of Clonazepam in Various Samples: Study of the Modifier Effect
    Keshtkar, Nasrin
    Rajabi, Hamid Reza
    Roushani, Mahmoud
    Abedi, Fardin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2024, 11 (04): : 405 - 414
  • [45] Molecularly imprinted polymer (biomimetic) based potentiometric sensor for atrazine
    Prasad, K.
    Prathish, K. P.
    Gladis, J. Mary
    Naidu, G. R. K.
    Rao, T. Prasada
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) : 65 - 70
  • [46] Selective quantification of diclofenac from groundwater and pharmaceutical samples by magnetic molecularly imprinted polymer-based sorbent coupled with the HPLC-PDA detection
    Thakur, Sahil
    Mohiuddin, Irshad
    Singh, Raghubir
    Kaur, Varinder
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (27) : 70871 - 70883
  • [47] Molecularly Imprinted Polymer Based Sensors for Medical Applications
    Saylan, Yeseren
    Akgonullu, Semra
    Yavuz, Handan
    Unal, Serhat
    Denizli, Adil
    SENSORS, 2019, 19 (06):
  • [48] Selective quantification of diclofenac from groundwater and pharmaceutical samples by magnetic molecularly imprinted polymer-based sorbent coupled with the HPLC-PDA detection
    Sahil Thakur
    Irshad Mohiuddin
    Raghubir Singh
    Varinder Kaur
    Environmental Science and Pollution Research, 2023, 30 : 70871 - 70883
  • [49] Molecularly imprinted polymer-based potentiometric sensors
    Wang, Junhao
    Liang, Rongning
    Qin, Wei
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 130
  • [50] Highly selective magnetic molecularly imprinted polymer for preconcentration and determination of atorvastatin in human urine samples
    Oshaghi, Shadi
    MICROCHEMICAL JOURNAL, 2024, 206