Dosimetric comparison of glioblastoma radiotherapy treatment plans on a low-field MRI-guided linear accelerator compared to conventional C-arm linear accelerator

被引:1
|
作者
Moats, Emily [1 ]
Siddiqui, Salim [1 ]
Parikh, Parag [1 ]
Snyder, Karen Chin [1 ]
机构
[1] Henry Ford Hlth, Detroit, MI 48202 USA
关键词
MRI-guided radiation therapy; MR-linac; Adaptive radiotherapy; Glioblastoma;
D O I
10.1016/j.meddos.2023.12.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Magnetic resonance imaging (MRI)-guided radiation therapy has proven to provide many benefits such as real-time tracking, dose escalation, and the ability to perform online adaptive therapy. The objective of this study is to compare curative treatment plans for glioblastoma tumors on a low-field MR-guided linac vs a C-arm linac and evaluate if they are comparable in terms of coverage, organ at risk sparing, delivery time, and deliverability. Methods: This is a retrospective study that consisted of 15 previously treated patients who received radiation therapy for glioblastoma on a C-arm linac. The CT simulation data used for the original clinical plans was imported into the MR-linac treatment planning system (TPS) and utilized for MR-linac plan generation. The plans were evaluated utilizing the dose volumetric histogram (DVH) and isodose lines, then compared in terms of plan quality consisting of PTV coverage, dose distributions, and OAR constraints. Statistical analysis was performed to compare differences between the two planning techniques. QA was performed on a subset of the plans to verify deliverability. Results: Plans generated on the MR-linac were more heterogenous compared to C-arm linac plans. A statistically significant difference was found in the homogeneity index (HI) and the PTV V105% volume (cc) values. The volume of the normal brain receiving 30 Gy also showed a statistically significant ( p = 0.0479) difference, where on average an additional 41.5 cc's of the normal brain tissue received 30 Gy in the MRlinac plans. The maximum dose to the normal brain structure also increased in the MR-linac plans on average by 2.6 Gy ( p = 0.0 0 02). Similarly, the average maximum dose to the scalp 4 mm structure was 6.5 Gy higher in the MR-linac plans compared to C-arm linac plans ( p = 0.0103). The total MU's were higher in the MR-linac plans compared to the C-arm linac plans ( p = 0.0015). Conclusions: Both MR-linac and C-arm linac plans met constraints for PTV coverage and OAR sparing, were deliverable, and resulted to be clinically acceptable. However, our study showed that MR-linac plans were not as conformal or as homogenous as C-arm linac plans utilizing noncoplanar beams. (c) 2024 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 30 条
  • [21] Three-dimensional conformal arc radiotherapy using a C-arm linear accelerator with a computed tomography on-rail system for prostate cancer: clinical outcomes
    Kumabe, Atsuhiro
    Fukuhara, Noboru
    Utsunomiya, Takuji
    Kawase, Takatsugu
    Iwata, Kunihiro
    Okada, Yukinori
    Sutani, Shinya
    Ohashi, Toshio
    Oya, Mototsugu
    Shigematsu, Naoyuki
    RADIATION ONCOLOGY, 2015, 10
  • [22] Three-dimensional conformal arc radiotherapy using a C-arm linear accelerator with a computed tomography on-rail system for prostate cancer: clinical outcomes
    Atsuhiro Kumabe
    Noboru Fukuhara
    Takuji Utsunomiya
    Takatsugu Kawase
    Kunihiro Iwata
    Yukinori Okada
    Shinya Sutani
    Toshio Ohashi
    Mototsugu Oya
    Naoyuki Shigematsu
    Radiation Oncology, 10
  • [23] Comparative Dosimetric, Setup Margin and Treatment Time Analysis Between Ring Gantry and C-Arm Linear Accelerators for VMAT Based Craniospinal Irradiation Plans
    Biswal, S.
    Sarkar, B.
    Goyal, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E913 - E913
  • [24] Comparative dosimetric, setup margin, and treatment time analysis between ring gantry and C-Arm linear accelerators for VMAT-based craniospinal irradiation plans
    Biswal, Subhra S.
    Sarkar, Biplab
    Goyal, Monika
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (01) : 224 - 231
  • [25] Association of Internal and External Motion Based on Cine MR Images Acquired During Real-Time Treatment on MRI-Guided Linear Accelerator for Patients With Lung Cancer
    Mao, Weihua
    Kim, Joshua
    Chetty, Indrin J.
    ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (01)
  • [26] Comparison of Prospectively Generated Glioma Treatment Plans Clinically Delivered on Magnetic Resonance Imaging (MRI)-Linear Accelerator (MR-Linac) Versus Conventional Linac: Predicted and Measured Skin Dose
    Wang, Michael H.
    Kim, Anthony
    Ruschin, Mark
    Tan, Hendrick
    Soliman, Hany
    Myrehaug, Sten
    Detsky, Jay
    Husain, Zain
    Atenafu, Eshetu G.
    Keller, Brian
    Sahgal, Arjun
    Tseng, Chia-Lin
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [27] Application of real-time MRI-guided linear accelerator in stereotactic ablative body radiotherapy for non-small cell lung cancer: one step forward to precise targeting
    Hye Jin Kang
    Yoo-Kang Kwak
    Myungsoo Kim
    So Jung Lee
    Journal of Cancer Research and Clinical Oncology, 2022, 148 : 3215 - 3223
  • [28] Application of real-time MRI-guided linear accelerator in stereotactic ablative body radiotherapy for non-small cell lung cancer: one step forward to precise targeting
    Kang, Hye Jin
    Kwak, Yoo-Kang
    Kim, Myungsoo
    Lee, So Jung
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2022, 148 (11) : 3215 - 3223
  • [29] Dosimetric comparison of Gamma Knife® Icon™ and linear accelerator-based fractionated stereotactic radiotherapy (FSRT) plans for the re-irradiation of large (>14 cm3) recurrent glioblastomas
    Schelin, Matthew E.
    Liu, Haisong
    Ali, Ayesha
    Shi, Wenyin
    Yu, Yan
    Mooney, Karen E.
    JOURNAL OF RADIOSURGERY AND SBRT, 2020, 7 (03): : 233 - 243
  • [30] Could the Jawless Flattening-Filter-Free Double-Mlc Layer Machine Reduce Low-Dose Regions Compared to Conventional Linear Accelerator for Large-Field Pelvic and Abdominal IMRT/VMAT Cases?
    Jang, S.
    Teo, P. T.
    Heron, D. E.
    Huq, M. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E494 - E494