Dosimetric comparison of glioblastoma radiotherapy treatment plans on a low-field MRI-guided linear accelerator compared to conventional C-arm linear accelerator

被引:1
|
作者
Moats, Emily [1 ]
Siddiqui, Salim [1 ]
Parikh, Parag [1 ]
Snyder, Karen Chin [1 ]
机构
[1] Henry Ford Hlth, Detroit, MI 48202 USA
关键词
MRI-guided radiation therapy; MR-linac; Adaptive radiotherapy; Glioblastoma;
D O I
10.1016/j.meddos.2023.12.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Magnetic resonance imaging (MRI)-guided radiation therapy has proven to provide many benefits such as real-time tracking, dose escalation, and the ability to perform online adaptive therapy. The objective of this study is to compare curative treatment plans for glioblastoma tumors on a low-field MR-guided linac vs a C-arm linac and evaluate if they are comparable in terms of coverage, organ at risk sparing, delivery time, and deliverability. Methods: This is a retrospective study that consisted of 15 previously treated patients who received radiation therapy for glioblastoma on a C-arm linac. The CT simulation data used for the original clinical plans was imported into the MR-linac treatment planning system (TPS) and utilized for MR-linac plan generation. The plans were evaluated utilizing the dose volumetric histogram (DVH) and isodose lines, then compared in terms of plan quality consisting of PTV coverage, dose distributions, and OAR constraints. Statistical analysis was performed to compare differences between the two planning techniques. QA was performed on a subset of the plans to verify deliverability. Results: Plans generated on the MR-linac were more heterogenous compared to C-arm linac plans. A statistically significant difference was found in the homogeneity index (HI) and the PTV V105% volume (cc) values. The volume of the normal brain receiving 30 Gy also showed a statistically significant ( p = 0.0479) difference, where on average an additional 41.5 cc's of the normal brain tissue received 30 Gy in the MRlinac plans. The maximum dose to the normal brain structure also increased in the MR-linac plans on average by 2.6 Gy ( p = 0.0 0 02). Similarly, the average maximum dose to the scalp 4 mm structure was 6.5 Gy higher in the MR-linac plans compared to C-arm linac plans ( p = 0.0103). The total MU's were higher in the MR-linac plans compared to the C-arm linac plans ( p = 0.0015). Conclusions: Both MR-linac and C-arm linac plans met constraints for PTV coverage and OAR sparing, were deliverable, and resulted to be clinically acceptable. However, our study showed that MR-linac plans were not as conformal or as homogenous as C-arm linac plans utilizing noncoplanar beams. (c) 2024 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 30 条
  • [1] Dosimetric feasibility of hippocampal avoidance whole brain radiotherapy with an MRI-guided linear accelerator
    Graham, Jasmine A.
    Redler, Gage
    Delozier, Kirby B.
    Yu, Hsiang-Hsuan Michael
    Oliver, Daniel E.
    Rosenberg, Stephen A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (06):
  • [2] Dosimetric Feasibility of HA-WBRT With an MRI-Guided Linear Accelerator
    Graham, J.
    Redler, G.
    DeLozier, K.
    Yu, H. H. M.
    Oliver, D. E.
    Rosenberg, S. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E511 - E512
  • [3] Dosimetric quality and delivery efficiency of robotic radiosurgery for brain metastases: Comparison with C-arm linear accelerator based plans
    Zhang, Shuming
    Yang, Ruijie
    Wang, Xin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (11): : 104 - 110
  • [4] Initial Experience With Online Adaptive Radiotherapy Workflows on an MRI-guided Linear Accelerator
    Williams, C. L.
    Huynh, E.
    Campbell, J.
    Penney, J.
    Boyle, S.
    Usta, I.
    Sugar, E. Neubauer
    Hacker, F. L.
    Han, Z.
    Price, A.
    Singer, L.
    Cagney, D. N.
    Mak, R. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E348 - E348
  • [5] A Dosimetric Comparison of MRI-Guided Cobalt-60 to Linear Accelerator-Based Stereotactic Ablative Radiation Lung Cancer Plans
    Wojcieszynski, A. P.
    Hill, P. M.
    Rosenberg, S. A.
    Hullett, C. R.
    Labby, Z. E.
    Paliwal, B. R.
    Geurts, M. W.
    Bayliss, R. A. B.
    Bayouth, J.
    Bassetti, M.
    Baschnagel, A. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E588 - E588
  • [6] Advantages of a novel 540° C-arm medical linear accelerator for volume intensity-modulated radiotherapy: An analysis
    Huang, Shixiong
    Yang, Songhua
    Yao, Wei
    Sun, Xiangshang
    Luo, Wei
    Zhang, Kang
    Shi, Yingrui
    Zeng, Biao
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2025, 18 (01)
  • [7] Adaptive treatment workflow and dosimetric evaluation of intracranial fractionated stereotactic radiosurgery on a low-field magnetic resonance-linear accelerator☆
    Snyder, Karen Chin
    Siddiqui, Salim M.
    Parikh, Parag
    Thind, Kundan
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2025, 33
  • [8] Dosimetric comparison of O-ring versus conventional C-arm linear accelerator for volumetric modulated arc therapy (VMAT) of head and neck cancer and carcinoma cervix patients
    Patodi, Vibhor
    Soni, Tej P.
    Singh, Dinesh K.
    Patni, Nidhi
    Jakhotia, Naresh
    Chittappurath, Vineeth
    Kuyyanangadan, Rajkamal
    Jenny, Ashna
    Kanniyappan, Elumalai
    Gupta, Anil K.
    Gupta, Tara C.
    Singhal, Harish
    Natrajan, Thirumoorthy
    Kather, Farzana S.
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (06) : 538 - 543
  • [9] Dosimetric Comparison of Real-Time MRI-Guided Tri-Cobalt-60 Versus Linear Accelerator-Based Stereotactic Body Radiation Therapy Lung Cancer Plans
    Wojcieszynski, Andrzej P.
    Hill, Patrick M.
    Rosenberg, Stephen A.
    Hullett, Craig R.
    Labby, Zacariah E.
    Paliwal, Bhudatt
    Geurts, Mark W.
    Bayliss, R. Adam
    Bayouth, John E.
    Harari, Paul M.
    Bassetti, Michael F.
    Baschnagel, Andrew M.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (03) : 366 - 372
  • [10] The Physics of Magnetic Field Isolation in a Novel Compact Linear Accelerator Based MRI-Guided Radiation Therapy System
    Low, D.
    Mutic, S.
    Shvartsman, S.
    Chmielewski, T.
    Fought, G.
    Sharma, A.
    Dempsey, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3768 - 3768